Evaluation of JPEG and wavelet compression of body CT images for direct digital teleradiologic transmission.

A Kalyanpur1, V P Neklesa, C R Taylor, A R Daftary, J A Brink.   

Abstract

PURPOSE: To determine acceptable levels of JPEG (Joint Photographic Experts Group) and wavelet compression for teleradiologic transmission of body computed tomographic (CT) images.
MATERIALS AND METHODS: A digital test pattern (Society of Motion Picture and Television Engineers, 512 x 512 matrix) was transmitted after JPEG or wavelet compression by using point-to-point and Web-based teleradiology, respectively. Lossless, 10:1 lossy, and 20:1 lossy ratios were tested. Images were evaluated for high- and low-contrast resolution, sensitivity to small signal differences, and misregistration artifacts. Three independent observers who were blinded to the compression scheme evaluated these image quality measures in 20 clinical cases with similar levels of compression.
RESULTS: High-contrast resolution was not diminished with any tested level of JPEG or wavelet compression. With JPEG compression, low-contrast resolution was not lost with 10:1 lossy compression but was lost at 3% modulation with 20:1 lossy compression. With wavelet compression, there was loss of 1% modulation with 10:1 lossy compression and loss of 5% modulation with 20:1 lossy compression. Sensitivity to small signal differences (5% and 95% of the maximal signal) diminished only with 20:1 lossy wavelet compression. With 10:1 lossy compression, misregistration artifacts were mild and were equivalent with JPEG and wavelet compression. Qualitative clinical findings supported these findings.
CONCLUSION: Lossy 10:1 compression is suitable for on-call electronic transmission of body CT images as long as original images are subsequently reviewed.

Mesh:

Year:  2000        PMID: 11110942     DOI: 10.1148/radiology.217.3.r00nv22772

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

1.  Evaluation of a filmless radiology pilot--a preliminary report.

Authors:  C G Mast; M A Caruso; C S Gadd; H J Lowe
Journal:  Proc AMIA Symp       Date:  2001

2.  Emergency radiology coverage: technical and clinical feasibility of an international teleradiology model.

Authors:  Arjun Kalyanpur; Joy Weinberg; Vladimir Neklesa; James A Brink; Howard P Forman
Journal:  Emerg Radiol       Date:  2003-07-22

3.  JPEG2000 for automated quantification of immunohistochemically stained cell nuclei: a comparative study with standard JPEG format.

Authors:  Marylène Lejeune; Carlos López; Ramón Bosch; Anna Korzyńska; Maria-Teresa Salvadó; Marcial García-Rojo; Urszula Neuman; Łukasz Witkowski; Jordi Baucells; Joaquín Jaén
Journal:  Virchows Arch       Date:  2010-11-18       Impact factor: 4.064

4.  A novel medical image quality index.

Authors:  Sheng-Chieh Lin; You-Chen Lin; Weng-Song Feng; Jia-Ming Wu; Tzong-Jer Chen
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

5.  Swiss teleradiology survey: present situation and future trends.

Authors:  Bernhard Lienemann; Juerg Hodler; Marcus Luetolf; Christian W A Pfirrmann
Journal:  Eur Radiol       Date:  2005-04-15       Impact factor: 5.315

6.  Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold.

Authors:  Kyoung Ho Lee; Young Hoon Kim; Bo Hyoung Kim; Kil Joong Kim; Tae Jung Kim; Hyuk Jung Kim; Seokyung Hahn
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 5.315

7.  Quality of compressed medical images.

Authors:  Ya-Hui Shiao; Tzong-Jer Chen; Keh-Shih Chuang; Cheng-Hsun Lin; Chun-Chao Chuang
Journal:  J Digit Imaging       Date:  2007-02-22       Impact factor: 4.056

8.  A parallel method to improve medical image transmission.

Authors:  Rouzbeh Maani; Sergio Camorlinga; Neil Arnason
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

9.  Computed Tomography Image Compressibility and Limitations of Compression Ratio-Based Guidelines.

Authors:  Jean-François Pambrun; Rita Noumeir
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

10.  User interface of a teleradiology system for the MR assessment of multiple sclerosis.

Authors:  G Luccichenti; F Cademartiri; A Pichiecchio; E Bontempi; U Sabatini; S Bastianello
Journal:  J Digit Imaging       Date:  2009-07-15       Impact factor: 4.056

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.