Literature DB >> 12105705

Impact of multislice CT on PACS resources.

Eric P Tamm1, Steve Thompson, Steven L Venable, Kevin McEnery.   

Abstract

Multislice CT (MSCT), which allows for shorter scan times and thinner slice sections than single-slice helical CT (SSHCT), will likely increase the demands on picture imaging and communication system (PACS) resources. Weekly averages for number of images per study (IPS) were collected from MSCT and SSHCT scanners from 1-01 to 7-01. Average cycle times (ACT) and number of studies per patient (ANSPP) were analyzed from two MSCT and SSHCT scanners for the period of 1-1-00 to 4-1-01, and 4-1-01 to 8-1-01. For SSHCT, the average IPS for 1-8-01 was 79.9 SD 4.2, and for 7-30-01, 113 SD 16.6. For MSCT scanners, the average for 1-8-01 was 142.2 SD 8.9, and for 7-30-01, 197 SD 39. The ACT prior to 4-1-01 for the SSHCT scanners was 17.9 SD 8.3, 18.3 SD 8.4. For MSCT, they were 19.6 SD 8.7, 19.2 SD 8.6. This was significant at P <0.001. After 4-1-01, the ACT for SSHCT was 18.6 SD 8.0, and 18.6 SD 7.9. For MSCT, they were 19.1 SD 8.3, and 18.8 SD 8.3. The difference was not significant. The ANSPP prior to 4-1-01 for SSHCT was 1.8 SD 0.8. For MSCT scanners, it was 1.9 SD 0.8. This was significant at P <0.0001. The ANSPP after 4-1-01 for SSHCT were 1.9 SD 0.8, 1.8 SD 0.8; for MSCT, they were 2.0 SD 0.8, 2.0 SD 0.8. This was significant at P <0.0001. Implementation of MSCT could have a significant impact on PACS resources.

Entities:  

Mesh:

Year:  2002        PMID: 12105705     DOI: 10.1007/s10278-002-5004-2

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  6 in total

1.  Upload capacity and time-to-display of an image Web system during simultaneous up- and download processes.

Authors:  B Bergh; M Pietsch; A Schlaefke; I Garcia; T J Vogl
Journal:  Eur Radiol       Date:  2003-10-03       Impact factor: 5.315

2.  Managing the CT data explosion: initial experiences of archiving volumetric datasets in a mini-PACS.

Authors:  Kyoung Ho Lee; Hak Jong Lee; Jae Hyoung Kim; Heung Sik Kang; Kyung Won Lee; Helen Hong; Ho Jun Chin; Kyoo Seob Ha
Journal:  J Digit Imaging       Date:  2005-09       Impact factor: 4.056

3.  Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold.

Authors:  Kyoung Ho Lee; Young Hoon Kim; Bo Hyoung Kim; Kil Joong Kim; Tae Jung Kim; Hyuk Jung Kim; Seokyung Hahn
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 5.315

4.  On-the-fly generation of multiplanar reformation images independent of CT scanner type.

Authors:  Dong Kyun Jeong; Kyoung Ho Lee; Bo Hyoung Kim; Kil Joong Kim; Young Hoon Kim; Vasundhara Bajpai; Yeong Gil Shin
Journal:  J Digit Imaging       Date:  2007-03-24       Impact factor: 4.056

5.  Summation or axial slab average intensity projection of abdominal thin-section CT datasets: can they substitute for the primary reconstruction from raw projection data?

Authors:  Kyoung Ho Lee; Helen Hong; Seokyung Hahn; Bohyoung Kim; Kil Joong Kim; Young Hoon Kim
Journal:  J Digit Imaging       Date:  2007-09-06       Impact factor: 4.056

6.  Full-field digital mammography image data storage reduction using a crop tool.

Authors:  Bong Joo Kang; Sung Hun Kim; Yeong Yi An; Byung Gil Choi
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-10       Impact factor: 2.924

  6 in total