B1 field-insensitive transformers for RF-safe transmission lines.

Axel Krafft1, Sven Müller, Reiner Umathum, Wolfhard Semmler, Michael Bock.   

Abstract

OBJECTIVE: Integration of transformers into transmission lines suppresses radiofrequency (RF)-induced heating. New figure-of-eight-shaped transformer coils are compared to conventional loop transformer coils to assess their signal transmission properties and safety profile.
MATERIALS AND METHODS: The transmission properties of figure-of-eight-shaped transformers were measured and compared to transformers with loop coils. Experiments to quantify the effect of decoupling from the B1 field of the MR system were conducted. Temperature measurements were performed to demonstrate the effective reduction of RF-induced heating. The transformers were investigated during active tracking experiments.
RESULTS: Coupling to the B1 field was reduced by 18 dB over conventional loop-shaped transformer coils. MR images showed a significantly reduced artifact for the figure-of-eight- shaped coils generated by local flip-angle amplification. Comparable transmission properties were seen for both transformer types. Temperature measurements showed a maximal temperature increase of 30 K/3.5 K for an unsegmented/segmented cable. With a segmented transmission line a robotic assistance system could be successfully localized using active tracking.
CONCLUSION: The figure-of-eight-shaped transformer design reduces both RF field coupling with the MR system and artifact sizes. Anatomical structure close to the figure-of-eight-shaped transformer may be less obscured as with loop-shaped transformers if these transformers are integrated into e.g. intravascular catheters.

Mesh:

Substances:

Year:  2006        PMID: 17115123     DOI: 10.1007/s10334-006-0055-x

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  17 in total

1.  Heating around intravascular guidewires by resonating RF waves.

Authors:  M K Konings; L W Bartels; H F Smits; C J Bakker
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

2.  A multielement RF coil for MRI guidance of interventional devices.

Authors:  Q Zhang; M Wendt; A J Aschoff; J S Lewin; J L Duerk
Journal:  J Magn Reson Imaging       Date:  2001-07       Impact factor: 4.813

3.  MR coil design for simultaneous tip tracking and curvature delineation of a catheter.

Authors:  Sven Zuehlsdorff; Reiner Umathum; Steffen Volz; Peter Hallscheidt; Christian Fink; Wolfhard Semmler; Michael Bock
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

4.  Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging.

Authors:  D L Rubin; A V Ratner; S W Young
Journal:  Invest Radiol       Date:  1990-12       Impact factor: 6.016

5.  Transmission line for improved RF safety of interventional devices.

Authors:  Steffen Weiss; Peter Vernickel; Tobias Schaeffter; Volkmar Schulz; Bernhard Gleich
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

6.  A safe transmission line for MRI.

Authors:  Peter Vernickel; Volkmar Schulz; Steffen Weiss; Bernhard Gleich
Journal:  IEEE Trans Biomed Eng       Date:  2005-06       Impact factor: 4.538

7.  Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters.

Authors:  R A Omary; O Unal; D S Koscielski; R Frayne; F R Korosec; C A Mistretta; C M Strother; T M Grist
Journal:  J Vasc Interv Radiol       Date:  2000-09       Impact factor: 3.464

8.  A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures.

Authors:  O Unal; F R Korosec; R Frayne; C M Strother; C A Mistretta
Journal:  Magn Reson Med       Date:  1998-09       Impact factor: 4.668

9.  Vascular interventions guided by ultrafast MR imaging: evaluation of different materials.

Authors:  V D Köchli; G C McKinnon; E Hofmann; G K von Schulthess
Journal:  Magn Reson Med       Date:  1994-03       Impact factor: 4.668

10.  A Faraday effect position sensor for interventional magnetic resonance imaging.

Authors:  M Bock; R Umathum; J Sikora; S Brenner; E N Aguor; W Semmler
Journal:  Phys Med Biol       Date:  2006-02-01       Impact factor: 3.609

View more
  3 in total

1.  It's the little things: On the complexity of planar electrode heating in MRI.

Authors:  Johannes B Erhardt; Thomas Lottner; Jessica Martinez; Ali C Özen; Martin Schuettler; Thomas Stieglitz; Daniel B Ennis; Michael Bock
Journal:  Neuroimage       Date:  2019-03-29       Impact factor: 6.556

2.  Radial MRI with variable echo times: reducing the orientation dependency of susceptibility artifacts of an MR-safe guidewire.

Authors:  Katharina E Schleicher; Michael Bock; Klaus Düring; Stefan Kroboth; Axel J Krafft
Journal:  MAGMA       Date:  2017-08-02       Impact factor: 2.310

Review 3.  Interventional cardiovascular magnetic resonance: still tantalizing.

Authors:  Kanishka Ratnayaka; Anthony Z Faranesh; Michael A Guttman; Ozgur Kocaturk; Christina E Saikus; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-29       Impact factor: 5.364

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.