Literature DB >> 15968655

Transmission line for improved RF safety of interventional devices.

Steffen Weiss1, Peter Vernickel, Tobias Schaeffter, Volkmar Schulz, Bernhard Gleich.   

Abstract

A new concept is proposed to improve the safety of transmission lines with respect to heating during RF transmission. It is based on the integration of transformers into the transmission line. The concept was applied to an active tracking device. Miniature transformers were designed, and two types of tracking devices were built based on a standard line and a transformer line. Temperature measurements were performed for both devices during high specific absorption rate (SAR) scanning, and the suppression of RF heating to a physiologically non-relevant level was demonstrated for the transformer device. The transmission properties of the transformer line were examined in simulations and RF measurements. Active tracking with the transformer device performed robustly in the phantom. Because of the favorable signal transmission properties of the tested device, it is expected that the concept can be applied to the construction of clinical devices for tracking and intravascular imaging, which are RF-safe under clinical SAR conditions. Since the transformer line has a large bandwidth, the concept may also be applied for RF-safe transmission of non-MR signals.

Mesh:

Substances:

Year:  2005        PMID: 15968655     DOI: 10.1002/mrm.20543

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI.

Authors:  Fabio Settecase; Steven W Hetts; Alastair J Martin; Timothy P L Roberts; Anthony F Bernhardt; Lee Evans; Vincent Malba; Maythem Saeed; Ronald L Arenson; Walter Kucharzyk; Mark W Wilson
Journal:  Acad Radiol       Date:  2010-11-13       Impact factor: 3.173

3.  MRI-guided vascular access with an active visualization needle.

Authors:  Christina E Saikus; Kanishka Ratnayaka; Israel M Barbash; Jessica H Colyer; Ozgur Kocaturk; Anthony Z Faranesh; Robert J Lederman
Journal:  J Magn Reson Imaging       Date:  2011-11       Impact factor: 4.813

Review 4.  Advances in interventional cardiovascular MRI.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

5.  B1 field-insensitive transformers for RF-safe transmission lines.

Authors:  Axel Krafft; Sven Müller; Reiner Umathum; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2006-11-18       Impact factor: 2.310

Review 6.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

7.  Multimode intravascular RF coil for MRI-guided interventions.

Authors:  Krishna N Kurpad; Orhan Unal
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

Review 8.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

Review 9.  Engineering novel detectors and sensors for MRI.

Authors:  Chunqi Qian; Gary Zabow; Alan Koretsky
Journal:  J Magn Reson       Date:  2012-11-29       Impact factor: 2.229

Review 10.  Cardiovascular magnetic resonance guided electrophysiology studies.

Authors:  Aravindan Kolandaivelu; Albert C Lardo; Henry R Halperin
Journal:  J Cardiovasc Magn Reson       Date:  2009-07-06       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.