Literature DB >> 11436215

A multielement RF coil for MRI guidance of interventional devices.

Q Zhang1, M Wendt, A J Aschoff, J S Lewin, J L Duerk.   

Abstract

Accurate localization of minimally invasive devices is critical to the success of interventional procedures. Device orientation and tip position are two of the most important pieces of information needed to define device location for magnetic resonance imaging (MRI)-guided interventional procedures. While a single one-element micro coil incorporated into an interventional device has proven to be effective in some applications, it can only supply tip position information. However, multiple positions on the device are necessary to also determine its orientation. For this purpose, a novel single micro coil design with three separate winding elements that provides both the device orientation and tip position is described in this study. Definition of MR scan planes, by using the device orientation and the target tissue location, permits automatic tracking of the insertion of the device. Furthermore, devices that include this coil design are permitted to bend to a limited extent. This makes the micro coil design appropriate for many flexible interventional devices. Reliable near-real-time tracking of three points on an interventional device is demonstrated on a 0.2T MRI system with modest gradient performance. Phantom and in vivo animal experiments are used to demonstrate the utility of this new coil design. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11436215     DOI: 10.1002/jmri.1151

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

1.  A brief review of hardware for catheter tracking in magnetic resonance imaging.

Authors:  Jeffrey L Duerk; Eddy Y Wong; Jonathan S Lewin
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

2.  B1 field-insensitive transformers for RF-safe transmission lines.

Authors:  Axel Krafft; Sven Müller; Reiner Umathum; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2006-11-18       Impact factor: 2.310

3.  Clinical feasibility of a magnetic resonance tracking system to guide the position of the scan plane during physiologic joint motion.

Authors:  J Vandevenne; A Pearle; P Lang; K Butts Pauly; G Bergman
Journal:  Radiol Med       Date:  2009-12-28       Impact factor: 3.469

4.  Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging.

Authors:  Xiaoliang Zhang; Alastair Martin; Caroline Jordan; Prasheel Lillaney; Aaron Losey; Yong Pang; Jeffrey Hu; Mark Wilson; Daniel Cooke; Steven W Hetts
Journal:  Quant Imaging Med Surg       Date:  2017-04

5.  Invasive human magnetic resonance imaging: feasibility during revascularization in a combined XMR suite.

Authors:  Alexander J Dick; Venkatesh K Raman; Amish N Raval; Michael A Guttman; Richard B Thompson; Cengizhan Ozturk; Dana C Peters; Annette M Stine; Victor J Wright; William H Schenke; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2005-03       Impact factor: 2.692

Review 6.  An overview on the advances in cardiovascular interventional MR imaging.

Authors:  Olaf Saborowski; Maythem Saeed
Journal:  MAGMA       Date:  2007-05-09       Impact factor: 2.310

7.  MRI-Guided Electrophysiology Intervention.

Authors:  Henry R Halperin; Aravindan Kolandaivelu
Journal:  Rambam Maimonides Med J       Date:  2010-10-31

Review 8.  Cardiovascular magnetic resonance guided electrophysiology studies.

Authors:  Aravindan Kolandaivelu; Albert C Lardo; Henry R Halperin
Journal:  J Cardiovasc Magn Reson       Date:  2009-07-06       Impact factor: 5.364

9.  Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes.

Authors:  Ozgur Kocaturk; Christina E Saikus; Michael A Guttman; Anthony Z Faranesh; Kanishka Ratnayaka; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2009-08-12       Impact factor: 5.364

10.  Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions.

Authors:  Francesca Galassi; Djordje Brujic; Marc Rea; Nicholas Lambert; Nandita Desouza; Mihailo Ristic
Journal:  MAGMA       Date:  2014-05-07       Impact factor: 2.310

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.