OBJECTIVES: We sought to determine the diagnostic performance of whole-heart coronary magnetic resonance (MR) angiography for detecting significant coronary artery disease. BACKGROUND: The accuracy of whole-heart coronary MR angiography has not been determined in a large number of patients. METHODS: Three-dimensional coronary MR angiograms covering the entire heart were obtained during free breathing in 131 patients. Images were acquired during a patient-specific time window in the cardiac cycle with minimal motion of the coronary artery. Significant coronary artery disease was defined on X-ray coronary angiography as a diameter reduction of > or =50% in coronary arteries with a reference diameter of > or =2 mm. RESULTS: The acquisition of MR angiography was completed in 113 (86%) of 131 patients, with an imaging time averaged at 12.9 +/- 4.3 min. On a patient-based analysis, the sensitivity, specificity, positive and negative predictive value, and accuracy of MR angiography were 82% (95% confidence interval [CI] 69% to 91%), 90% (95% CI 79% to 96%), 88% (95% CI 74% to 95%), 86% (95% CI 75% to 93%), and 87% (95% CI 79% to 92%), respectively. These values in the individual segments were 78% (95% CI 68% to 85%), 96% (95% CI 95% to 97%), 69% (95% CI 60% to 77%), 98% (95% CI 96% to 98%), and 94% (95% CI 96% to 96%). CONCLUSIONS: Whole-heart coronary MR angiography allows for noninvasive detection of significant narrowing in coronary arterial segments with a diameter of > or =2 mm with moderate sensitivity and high specificity.
OBJECTIVES: We sought to determine the diagnostic performance of whole-heart coronary magnetic resonance (MR) angiography for detecting significant coronary artery disease. BACKGROUND: The accuracy of whole-heart coronary MR angiography has not been determined in a large number of patients. METHODS: Three-dimensional coronary MR angiograms covering the entire heart were obtained during free breathing in 131 patients. Images were acquired during a patient-specific time window in the cardiac cycle with minimal motion of the coronary artery. Significant coronary artery disease was defined on X-ray coronary angiography as a diameter reduction of > or =50% in coronary arteries with a reference diameter of > or =2 mm. RESULTS: The acquisition of MR angiography was completed in 113 (86%) of 131 patients, with an imaging time averaged at 12.9 +/- 4.3 min. On a patient-based analysis, the sensitivity, specificity, positive and negative predictive value, and accuracy of MR angiography were 82% (95% confidence interval [CI] 69% to 91%), 90% (95% CI 79% to 96%), 88% (95% CI 74% to 95%), 86% (95% CI 75% to 93%), and 87% (95% CI 79% to 92%), respectively. These values in the individual segments were 78% (95% CI 68% to 85%), 96% (95% CI 95% to 97%), 69% (95% CI 60% to 77%), 98% (95% CI 96% to 98%), and 94% (95% CI 96% to 96%). CONCLUSIONS: Whole-heart coronary MR angiography allows for noninvasive detection of significant narrowing in coronary arterial segments with a diameter of > or =2 mm with moderate sensitivity and high specificity.
Authors: W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard Journal: Circulation Date: 2010-05-17 Impact factor: 29.690
Authors: W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard Journal: J Am Coll Cardiol Date: 2010-06-08 Impact factor: 24.094
Authors: Ahmed M Gharib; Daniel A Herzka; Ali O Ustun; Milind Y Desai; Julia Locklin; Roderic I Pettigrew; Matthias Stuber Journal: J Magn Reson Imaging Date: 2007-10 Impact factor: 4.813
Authors: Grigorios Korosoglou; Robert G Weiss; Dorota A Kedziorek; Piotr Walczak; Wesley D Gilson; Michael Schär; David E Sosnovik; Dara L Kraitchman; Raymond C Boston; Jeff W M Bulte; Ralph Weissleder; Matthias Stuber Journal: J Am Coll Cardiol Date: 2008-08-05 Impact factor: 24.094
Authors: Richard M McCarthy; Vibhas S Deshpande; Nirat Beohar; Sheridan N Meyers; Steven M Shea; Jordin D Green; Xin Liu; Xiaoming Bi; F Scott Pereles; John Paul Finn; Charles J Davidson; James C Carr; Debiao Li Journal: Invest Radiol Date: 2007-10 Impact factor: 6.016
Authors: Thanh D Nguyen; Pascal Spincemaille; Matthew D Cham; Jonathan W Weinsaft; Martin R Prince; Yi Wang Journal: J Magn Reson Imaging Date: 2008-08 Impact factor: 4.813