Literature DB >> 17106364

Manometric calibration and comparison of TonoLab and TonoPen tonometers in rats with experimental glaucoma and in normal mice.

Mary E Pease1, John C Hammond, Harry A Quigley.   

Abstract

PURPOSE: To compare the TonoPen and TonoLab tonometers to each other and to manometrically set intraocular pressure (IOP) in the eyes of normal mice, normal rats, and rats with chronic IOP elevation.
METHODS: The measurement of IOP by the TonoPen and TonoLab tonometers was made in 21 normal rat eyes, 10 normal mouse eyes, and 16 rats that had either 2 or 4-week experimental glaucoma. IOP was varied from 10 to 50 mm Hg in steps of 10 mm Hg under conditions in which the eye was either open or closed to the reservoir controlling IOP.
RESULTS: In normal rat eyes, TonoPen overestimated manometric IOP at 10 mm Hg and underestimated it by up to 6 mm Hg at higher IOP, whereas the TonoLab matched set IOP within 1 mm Hg. In glaucoma rat eyes, the TonoLab accurately reflected manometric IOP under open stopcock conditions (linear regression: y = 0.99x -0.62, R = 0.98), whereas in the closed stopcock condition, IOP measured lower at the higher IOP levels (P = 0.0059, paired t test). In uncannulated rat glaucoma eyes, the tonometer used first gave higher IOP [paired t test, P = 0.015 (TonoLab first); P = 0.005 (TonoPen first)]. In normal mouse eyes under the open stopcock condition, the TonoLab nearly matched manometric IOP (linear regression: y = 0.98x + 1.57, R = 0.98).
CONCLUSIONS: In mouse and rat eyes, including rats with chronic IOP elevation, the TonoLab accurately reflected manometrically set IOP in an efficient manner.

Entities:  

Mesh:

Year:  2006        PMID: 17106364     DOI: 10.1097/01.ijg.0000212276.57853.19

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  32 in total

1.  Calibration of the TonoLab tonometer in mice with spontaneous or experimental glaucoma.

Authors:  Mary E Pease; Frances E Cone; Scott Gelman; Janice L Son; Harry A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-22       Impact factor: 4.799

Review 2.  Modeling glaucoma in rats by sclerosing aqueous outflow pathways to elevate intraocular pressure.

Authors:  John C Morrison; William O Cepurna; Elaine C Johnson
Journal:  Exp Eye Res       Date:  2015-05-21       Impact factor: 3.467

3.  Reliability of Tonolab measurements in rats.

Authors:  Li-Fang Liu; Chu-Kai Huang; Ming-Zhi Zhang
Journal:  Int J Ophthalmol       Date:  2014-12-18       Impact factor: 1.779

4.  Central corneal thickness does not correlate with TonoLab-measured IOP in several mouse strains with single transgenic mutations of matricellular proteins.

Authors:  Ayan Chatterjee; Dong-Jin Oh; Min Hyung Kang; Douglas J Rhee
Journal:  Exp Eye Res       Date:  2013-06-24       Impact factor: 3.467

5.  Transgenic mice expressing mutated Tyr437His human myocilin develop progressive loss of retinal ganglion cell electrical responsiveness and axonopathy with normal iop.

Authors:  Tsung-Han Chou; Stanislav Tomarev; Vittorio Porciatti
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-08-14       Impact factor: 4.799

6.  Differential susceptibility to experimental glaucoma among 3 mouse strains using bead and viscoelastic injection.

Authors:  Frances E Cone; Scott E Gelman; Janice L Son; Mary E Pease; Harry A Quigley
Journal:  Exp Eye Res       Date:  2010-06-26       Impact factor: 3.467

7.  Efficient in vivo doxycycline and cre recombinase-mediated inducible transgene activation in the murine trabecular meshwork.

Authors:  Pu Liu; Xueyao Fu; Randy L Johnson
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-23       Impact factor: 4.799

8.  H-1152 effects on intraocular pressure and trabecular meshwork morphology of rat eyes.

Authors:  Man Yu; Xiaoming Chen; Ningli Wang; Suping Cai; Ni Li; Jinghua Qiu; Curtis R Brandt; Paul L Kaufman; Xuyang Liu
Journal:  J Ocul Pharmacol Ther       Date:  2008-08       Impact factor: 2.671

9.  Efficacy of TonoLab in detecting physiological and pharmacological changes in rat intraocular pressure: comparison of TonoPen and microneedle manometry.

Authors:  Masaaki Ohashi; Makoto Aihara; Tadashiro Saeki; Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2008-11-11       Impact factor: 2.447

10.  The influence of genetic background on conventional outflow facility in mice.

Authors:  Alexandra Boussommier-Calleja; Darryl R Overby
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-12-19       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.