Literature DB >> 17100747

Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans.

Antonio Scarano1, Marco Degidi, Giovanna Iezzi, Giovanna Petrone, Adriano Piattelli.   

Abstract

BACKGROUND: Primary stability has a relevant role in the long-term success of dental implants. A quantitative method for the measurement of implant stability has been introduced (resonance frequency analysis [RFA]). Information about the significance of RFA measurements and about the relationship between RFA values and their association with implant osseointegration, success, or failure is important from a clinical point of view.
PURPOSE: The aim of the present histological and histomorphometric study was to see if a correlation existed between the bone-implant contact (BIC) percentage of retrieved human implants and RFA values.
MATERIALS AND METHODS: Seven implants inserted in the posterior mandible, with a sandblasted and acid-etched surface and retrieved after a 6-month period, were evaluated in the present study. These seven implants had been retrieved for different causes. All these implants were submerged and were retrieved with a 5-mm trephine bur and immersed in 10% buffered formalin to be processed for histology.
RESULTS: A statistically significant correlation could be detected between implant stability quotient and BIC (p=.016).
CONCLUSIONS: Even if the relationship between bone structure and RFA is still not fully understood, in our study, a statistically significant correlation was found between RFA and BIC values. Further studies are needed to evaluate a correlation of RFA and BIC in human implants retrieved after a range of healing periods.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17100747     DOI: 10.1111/j.1708-8208.2006.00022.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  28 in total

1.  Implant stability evaluation by resonance frequency analysis in the fit lock technique. A clinical study.

Authors:  Giovanni Falisi; Massimo Galli; Pedro Vittorini Velasquez; Juan Carlos Gallegos Rivera; Carlo Di Paolo
Journal:  Ann Stomatol (Roma)       Date:  2013-06-25

2.  Histologic analysis of resorbable blasting media surface implants retrieved from humans: a report of two cases.

Authors:  Kyung-In Jeong; Young-Kyun Kim; Sang-Woon Moon; Su-Gwan Kim; Sung-Chul Lim; Pil-Young Yun
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-02-15

3.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

4.  Appearance of cell-adhesion factor in osteoblast proliferation and differentiation of apatite coating titanium by blast coating method.

Authors:  Hirotsugu Umeda; Takamitsu Mano; Koji Harada; Ferdous Tarannum; Yoshiya Ueyama
Journal:  J Mater Sci Mater Med       Date:  2017-06-15       Impact factor: 3.896

5.  Functional apparent moduli as predictors of oral implant osseointegration dynamics.

Authors:  Po-Chun Chang; Yang-Jo Seol; Noboru Kikuchi; Steven A Goldstein; William V Giannobile
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-07       Impact factor: 3.368

6.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

7.  Effect of Magnetic Field on Bone Healing around Endosseous Implants - An In-vivo Study.

Authors:  Mahalakshmi Gujjalapudi; Chandrasekar Anam; Praveen Mamidi; Radha Chiluka; A Gautam Kumar; Ragini Bibinagar
Journal:  J Clin Diagn Res       Date:  2016-10-01

8.  3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors.

Authors:  Yuxiao Zhou; Chujie Gong; Mehran Hossaini-Zadeh; Jing Du
Journal:  J Mech Behav Biomed Mater       Date:  2020-05-19

9.  The effect of various thread designs on the initial stability of taper implants.

Authors:  Ju-Hee Park; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

Review 10.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

View more