Literature DB >> 17090196

The variability of results between point-of-care testing glucose meters and the central laboratory analyzer.

Adil I Khan1, Yolanda Vasquez, Jacquelyn Gray, Frank H Wians, Martin H Kroll.   

Abstract

CONTEXT: Point-of-care testing glucose meters are strongly recommended in the management of diabetes and are increasingly being used for making therapeutically important decisions. Thus, it is essential that their results correlate well with those of laboratory analyzers.
OBJECTIVES: To test the reliability of point-of-care testing glucose meters.
DESIGN: Two studies were performed: (1), an in-house study comparing accuracy of point-of-care testing glucose meters with a reference analyzer using fresh whole blood specimens (2), a real-time comparison of (a) 2 successive glucose meter readings and (b) glucose meter reading to central laboratory analyzer reading.
SETTING: (1), Seven glucose meters from 4 manufacturers were compared with the Yellow Springs YSI 2300 blood glucose analyzer using whole blood without preservative. (2), (a) Whole blood samples were read within 5 minutes of each other using Accu-Chek meters and (b) between a glucose meter and a Hitachi laboratory analyzer.
RESULTS: (1) Within the Accu-Chek group of glucose meters, fresh, preservative-free whole blood samples showed the lowest bias. (2) At the hypoglycemic level, successive glucose meter readings agreed well, but there was considerable disagreement between glucose meter and central laboratory values. Because laboratory analyzers are of proven accuracy, they are used as the reference. In the glucose meter-central laboratory analyzer correlation, for both hypoglycemic and hyperglycemic values, readings in which the differences were greater than 10% occurred more than 61% of the time. In the hypoglycemic range, differences greater than 20% occurred 57% of the time.
CONCLUSIONS: One should scrutinize point-of-care testing glucose meter readings at the hypoglycemic and hyperglycemic levels and whenever possible to corroborate these clinical results with central laboratory analyzers.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17090196     DOI: 10.5858/2006-130-1527-TVORBP

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  26 in total

1.  Two hour blood glucose levels in at-risk babies: An audit of Canadian guidelines.

Authors:  Jennifer Croke; Meagan Sullivan; Anne Ryan-Drover; Ed Randell; Wayne Andrews; Khalid Aziz
Journal:  Paediatr Child Health       Date:  2009-04       Impact factor: 2.253

2.  Impact of Glucose Meter Error on Glycemic Variability and Time in Target Range During Glycemic Control After Cardiovascular Surgery.

Authors:  Brad S Karon; Jeffrey W Meeusen; Sandra C Bryant
Journal:  J Diabetes Sci Technol       Date:  2015-08-25

Review 3.  Accuracy of point-of-care glucose measurements.

Authors:  Annette Rebel; Mark A Rice; Brenda G Fahy
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

4.  Intermediary variables and algorithm parameters for an electronic algorithm for intravenous insulin infusion.

Authors:  Susan S Braithwaite; Hemant Godara; Julie Song; Bruce A Cairns; Samuel W Jones; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

Review 5.  Identification of myocardial injury in the emergency setting.

Authors:  Peter A Kavsak; Andrew Worster; John J You; Mark Oremus; Adell Elsharif; Stephen A Hill; P J Devereaux; Andrew R MacRae; Allan S Jaffe
Journal:  Clin Biochem       Date:  2009-12-21       Impact factor: 3.281

Review 6.  Intensive insulin therapy in critically ill hospitalized patients: making it safe and effective.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

7.  Utility of point-of-care vs reference laboratory testing for the evaluation of glucose levels.

Authors:  O M Andriankaja; F J Muñoz-Torres; J L Vergara; C M Pérez; K Joshipura
Journal:  Diabet Med       Date:  2019-03-01       Impact factor: 4.359

8.  A Comprehensive Performance Evaluation of Five Blood Glucose Systems in the Hypo-, Eu-, and Hyperglycemic Range.

Authors:  Eric Zijlstra; Lutz Heinemann; Annelie Fischer; Christoph Kapitza
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

9.  Evaluation of point-of-care glucose testing accuracy using locally-smoothed median absolute difference curves.

Authors:  Gerald J Kost; Nam K Tran; Victor J Abad; Richard F Louie
Journal:  Clin Chim Acta       Date:  2007-12-03       Impact factor: 3.786

10.  Assessing the performance of handheld glucose testing for critical care.

Authors:  Gerald J Kost; Nam K Tran; Richard F Louie; Nicole L Gentile; Victor J Abad
Journal:  Diabetes Technol Ther       Date:  2008-12       Impact factor: 6.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.