Literature DB >> 17089364

Improved echo volumar imaging (EVI) for functional MRI.

Wietske van der Zwaag1, Susan Francis, Richard Bowtell.   

Abstract

Echo volumar imaging (EVI) is a 3D modification of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single RF excitation. EVI provides a high rate of volumar data acquisition, which is advantageous for functional MRI (fMRI). However, few studies to date have applied EVI to fMRI, since because of gradient hardware limitations EVI generally has to be used with long sampling times, resulting in high sensitivity to susceptibility-induced distortions. In this study we modified the EVI sequence to improve its suitability for fMRI. The sampling time is reduced by the use of a high gradient-switching frequency, a small number of echoes, and outer volume suppression (OVS); rewind gradients ameliorate Nyquist ghosting; and phase correction via a calibration scan reduces ghosting and distortion. It is shown that the modified EVI sequence allows fMRI data to be acquired with a temporal resolution of 167 ms.

Entities:  

Mesh:

Year:  2006        PMID: 17089364     DOI: 10.1002/mrm.21080

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Reducing task-based fMRI scanning time using simultaneous multislice echo planar imaging.

Authors:  Máté Kiss; Petra Hermann; Zoltán Vidnyánszky; Viktor Gál
Journal:  Neuroradiology       Date:  2018-01-04       Impact factor: 2.804

2.  Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging.

Authors:  Stefan Posse; Elena Ackley; Radu Mutihac; Jochen Rick; Matthew Shane; Cristina Murray-Krezan; Maxim Zaitsev; Oliver Speck
Journal:  Neuroimage       Date:  2012-02-28       Impact factor: 6.556

3.  Temporal SNR characteristics in segmented 3D-EPI at 7T.

Authors:  W van der Zwaag; J P Marques; T Kober; G Glover; R Gruetter; G Krueger
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

4.  Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty.

Authors:  Kawin Setsompop; Borjan A Gagoski; Jonathan R Polimeni; Thomas Witzel; Van J Wedeen; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

5.  Three dimensional radial echo planar imaging for functional MRI.

Authors:  Christoph A Rettenmeier; Danilo Maziero; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

6.  Single-shot 3D GRASE with cylindrical k-space trajectories.

Authors:  S Ramanna; D A Feinberg
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

7.  Specific absorption rate studies of the parallel transmission of inner-volume excitations at 7T.

Authors:  Adam C Zelinski; Leonardo M Angelone; Vivek K Goyal; Giorgio Bonmassar; Elfar Adalsteinsson; Lawrence L Wald
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

8.  Three-dimensional Fourier encoding of simultaneously excited slices: generalized acquisition and reconstruction framework.

Authors:  Benjamin Zahneisen; Benedikt A Poser; Thomas Ernst; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2013-07-22       Impact factor: 4.668

9.  Volume parcellation for improved dynamic shimming.

Authors:  Michael Poole; Richard Bowtell
Journal:  MAGMA       Date:  2008-01-08       Impact factor: 2.310

Review 10.  Real-Time Magnetic Resonance Imaging.

Authors:  Krishna S Nayak; Yongwan Lim; Adrienne E Campbell-Washburn; Jennifer Steeden
Journal:  J Magn Reson Imaging       Date:  2020-12-09       Impact factor: 4.813

View more