Three-dimensional bone-implant integration profiling using micro-computed tomography.

Frank Butz1, Takahiro Ogawa, Ting-Ling Chang, Ichiro Nishimura.   

Abstract

PURPOSE: The capability of micro-computed tomography (microCT) for quantitative analysis of peri-implant bone has not been previously addressed. This study aimed to establish and validate a method to use this technique for 3-dimensional bone-implant integration profiling.
MATERIALS AND METHODS: Unthreaded cylindric implants with a dual acid-etched surface were placed into the right femurs of 7 Sprague-Dawley rats. Two weeks postimplantation, the femurs were harvested and measured with a desktop micro-tomographic scanner with an isotropic resolution of 8 microm. To validate the microCT outcome, ground histologic sections and corresponding CT slices were compared with respect to bone morphometry.
RESULTS: Bone-implant integration profiles assessed by microCT revealed that the percentage of cancellous bone gradually increased with proximity to the implant surface, while the percentage of cortical bone was not affected by proximity to the implant. Using the optimized segmentation threshold, the bone configuration in the microCT images corresponded to that observed in the histologic sections. The correlation between microCT and histology was significant for cortical (r = 0.65; P < .05) and cancellous bone (r = 0.92; P < .05) at distances of 24 to 240 microm from the implant surface, but no significant correlation was found for the area from 0 to 24 microm from the surface. DISCUSSION AND
CONCLUSION: The results support the usefulness of microCT assessment as a rapid, nondestructive method for 3-dimensional bone ratio measurements around implants, which may provide new perspectives for osseointegration research. Further study is necessary, however, to address the inherent metallic halation artifact, which potentially confounds peri-implant bone assessment.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17066629

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  19 in total

Review 1.  Application of polychromatic µCT for mineral density determination.

Authors:  W Zou; N Hunter; M V Swain
Journal:  J Dent Res       Date:  2010-09-21       Impact factor: 6.116

2.  The use of light/chemically hardened polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants and extraction sockets in minipigs: Part II: histologic and micro-CT evaluations.

Authors:  Hatice Hasturk; Alpdogan Kantarci; Mazen Ghattas; Smit J Dangaria; Rima Abdallah; Elise F Morgan; Thomas G H Diekwisch; Arthur Ashman; Thomas Van Dyke
Journal:  J Periodontol       Date:  2014-02-06       Impact factor: 6.993

3.  Degradation of Bioresorbable Mg-4Zn-1Sr Intramedullary Pins and Associated Biological Responses in Vitro and in Vivo.

Authors:  Aaron F Cipriano; Jiajia Lin; Alan Lin; Amy Sallee; Belinda Le; Mayra Celene Cortez Alcaraz; Ren-Guo Guan; Gary Botimer; Serkan Inceoğlu; Huinan Liu
Journal:  ACS Appl Mater Interfaces       Date:  2017-12-14       Impact factor: 9.229

4.  Limitations of using micro-computed tomography to predict bone-implant contact and mechanical fixation.

Authors:  S Liu; J Broucek; A S Virdi; D R Sumner
Journal:  J Microsc       Date:  2011-09-15       Impact factor: 1.758

5.  Biological effects of a porcine-derived collagen membrane on intrabony defects.

Authors:  Chang-Kyun Lee; Ki-Tae Koo; Tae-Il Kim; Yang-Jo Seol; Yong-Moo Lee; In-Chul Rhyu; Young Ku; Chong-Pyoung Chung; Yoon-Jeong Park; Jue-Yeon Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

6.  Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

Authors:  Matthew J Meagher; Rachna N Parwani; Amarjit S Virdi; Dale R Sumner
Journal:  J Orthop Res       Date:  2017-10-04       Impact factor: 3.494

7.  Determination of the dynamics of healing at the tissue-implant interface by means of microcomputed tomography and functional apparent moduli.

Authors:  Po-Chun Chang; Yang-Jo Seol; Steven A Goldstein; William V Giannobile
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

8.  PTH improves titanium implant fixation more than pamidronate or renutrition in osteopenic rats chronically fed a low protein diet.

Authors:  R Dayer; T C Brennan; R Rizzoli; P Ammann
Journal:  Osteoporos Int       Date:  2009-10-27       Impact factor: 4.507

9.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

10.  Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

Authors:  Sung-Won Kang; Woo-Jin Lee; Soon-Chul Choi; Sam-Sun Lee; Min-Suk Heo; Kyung-Hoe Huh; Tae-Il Kim; Won-Jin Yi
Journal:  Imaging Sci Dent       Date:  2015-03-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.