Literature DB >> 17065562

Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose?

Michael Macari1, Hersh Chandarana, Bernhardt Schmidt, Julie Lee, Patrick Lamparello, James Babb.   

Abstract

PURPOSE: To retrospectively determine if arterial phase computed tomographic (CT) imaging is necessary for follow-up imaging of patients who have undergone endovascular stent-graft therapy for abdominal aortic aneurysm.
MATERIALS AND METHODS: This HIPAA-compliant study was exempt from institutional review board approval; informed patient consent was waived. Eighty-five patients (66 men, 19 women; mean age, 66 years; range, 45-81 years) underwent 110 multidetector CT examinations after endovascular repair of abdominal aortic aneurysms. Nonenhanced CT images were obtained. Intravenous contrast material was then injected at 4 mL/sec, and arterial and venous phase (60 seconds) CT images were obtained. The nonenhanced and venous phase images were evaluated to determine if an endoleak was present. Subsequently, arterial phase images were analyzed. The effective dose was calculated. Ninety-five percent confidence intervals as indicators of how often arterial phase imaging would contribute to the diagnosis of endoleak were determined.
RESULTS: Twenty-eight type II endoleaks were detected by using combined nonenhanced and venous phase acquisitions. Twenty-five of the 28 endoleaks were also visualized during the arterial phase. Three type II endoleaks were seen only during the venous phase. The arterial phase images depicted no additional endoleaks. Seventy-eight CT examinations performed in 67 patients revealed no endoleak during the venous phase. The arterial phase images also depicted no endoleaks at these examinations. Thus, for no more than 3.1% of all examinations, there was 95% confidence that arterial phase imaging would depict an endoleak missed at venous phase imaging. Arterial phase imaging contributed to a mean of 36.5% of the effective dose delivered.
CONCLUSION: Study results indicate that arterial phase imaging may not be necessary for the routine detection of endoleaks. Radiation exposure can be decreased by eliminating this phase. (c) RSNA, 2006.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17065562     DOI: 10.1148/radiol.2413051571

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  20 in total

Review 1.  Surveillance Imaging Following Endovascular Aneurysm Repair.

Authors:  Nirnimesh Pandey; Harold I Litt
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

Review 2.  [Multidetector computed tomography in the diagnosis of non-traumatic vascular emergencies].

Authors:  B Baumert; M Körner; M Sadeghi-Azandaryani; C Rummeny; M Reiser; U Linsenmaier
Journal:  Radiologe       Date:  2009-06       Impact factor: 0.635

Review 3.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

4.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

5.  Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair.

Authors:  Vitaliano Buffa; Antonio Solazzo; Valeria D'Auria; Alessandra Del Prete; Andrea Vallone; Monica Luzietti; Manuela Madau; Roberto Grassi; Vittorio Miele
Journal:  Radiol Med       Date:  2014-07-02       Impact factor: 3.469

Review 6.  Contrast-enhanced ultrasound (CEUS) versus computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients. Are delayed type II endoleaks being missed? A systematic review and meta-analysis.

Authors:  J Chung; A Kordzadeh; I Prionidis; Y Panayiotopoulos; T Browne
Journal:  J Ultrasound       Date:  2015-01-17

7.  Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT.

Authors:  Anna Winklehner; Sonja Gordic; Eliane Lauk; Thomas Frauenfelder; Sebastian Leschka; Hatem Alkadhi; Daniela B Husarik
Journal:  Eur Radiol       Date:  2015-02-19       Impact factor: 5.315

Review 8.  How Can New Imaging Modalities Help in the Practice of Radiology?

Authors:  Berhan Pirimoglu; Recep Sade; Hayri Ogul; Mecit Kantarci; Suat Eren; Akın Levent
Journal:  Eurasian J Med       Date:  2016-10

9.  "Sweet spot" for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT.

Authors:  Katherine E Maturen; Ravi K Kaza; Peter S Liu; Leslie E Quint; Shokoufeh H Khalatbari; Joel F Platt
Journal:  J Comput Assist Tomogr       Date:  2012 Jan-Feb       Impact factor: 1.826

10.  High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate.

Authors:  Sonja Gordic; Daniela B Husarik; Lotus Desbiolles; Sebastian Leschka; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-11       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.