Literature DB >> 17063009

Temporal bone results and hearing preservation with a new straight electrode.

Thomas Lenarz1, Timo Stover, Andreas Buechner, Gerrit Paasche, Robert Briggs, Frank Risi, Joerg Pesch, Rolf-Dieter Battmer.   

Abstract

Due to improved technology, cochlear implant (CI) candidacy has been widened towards patients with usable residual hearing in the low frequency range. These patients might benefit from additional acoustic amplification provided that residual hearing can be preserved with cochlear implantation. To provide a high probability of hearing preservation, a new electrode array was designed and developed at the Medizinische Hochschule Hannover. This 'Hybrid-L' electrode array has 22 electrodes spread over 15 mm with an overall insertion depth of 16 mm. The straight electrode with modiolus facing contacts is designed for a round window insertion. It shall provide the full range of the currently most advanced Nucleus CI system. A temporal bone study demonstrated the favorable insertion characteristics and minimized trauma to intracochlear structures. Compared to standard CI electrodes especially no basilar membrane perforation could be found. So far, 4 patients have been implanted and residual hearing could be preserved. One patient was fitted and showed a marked additional benefit from the electroacoustic stimulation compared to either acoustic or electrical stimulation alone. These results are very encouraging towards a concept of reliable hearing preservation with cochlear implantation. Copyright (c) 2006 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2006        PMID: 17063009     DOI: 10.1159/000095612

Source DB:  PubMed          Journal:  Audiol Neurootol        ISSN: 1420-3030            Impact factor:   1.854


  42 in total

1.  Determination of the curling behavior of a preformed cochlear implant electrode array.

Authors:  Thomas S Rau; Omid Majdani; Andreas Hussong; Thomas Lenarz; Martin Leinung
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-07-28       Impact factor: 2.924

2.  [Which colours can we hear?: light stimulation of the hearing system].

Authors:  G I Wenzel; T Lenarz; B Schick
Journal:  HNO       Date:  2014-02       Impact factor: 1.284

Review 3.  The development of the Nucleus Freedom Cochlear implant system.

Authors:  James F Patrick; Peter A Busby; Peter J Gibson
Journal:  Trends Amplif       Date:  2006-12

Review 4.  Soft cochlear implantation: rationale for the surgical approach.

Authors:  David R Friedland; Christina Runge-Samuelson
Journal:  Trends Amplif       Date:  2009-06

Review 5.  [Hearing with combined electric acoustic stimulation].

Authors:  U Baumann; S Helbig
Journal:  HNO       Date:  2009-06       Impact factor: 1.284

6.  Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model.

Authors:  Thomas S Rau; Andreas Hussong; Martin Leinung; Thomas Lenarz; Omid Majdani
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-04-10       Impact factor: 2.924

7.  Bilateral Cochlear Implants Using Two Electrode Lengths in Infants With Profound Deafness.

Authors:  Camille C Dunn; Elizabeth A Walker; Stephanie Gogel; Tanya Van Voorst; Marlan Hansen; Bruce J Gantz
Journal:  Otol Neurotol       Date:  2019-03       Impact factor: 2.311

8.  Impact of the round window membrane accessibility on hearing preservation in adult cochlear implantation.

Authors:  Marjan Mirsalehi; Saleh Mohebbi; Mahsa Ghajarzadeh; Thomas Lenarz; Omid Majdani
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-06-06       Impact factor: 2.503

9.  A Preliminary Investigation of the Air-Bone Gap: Changes in Intracochlear Sound Pressure With Air- and Bone-conducted Stimuli After Cochlear Implantation.

Authors:  Renee M Banakis Hartl; Jameson K Mattingly; Nathaniel T Greene; Herman A Jenkins; Stephen P Cass; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2016-10       Impact factor: 2.311

10.  Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion.

Authors:  Nathaniel T Greene; Jameson K Mattingly; Renee M Banakis Hartl; Daniel J Tollin; Stephen P Cass
Journal:  Otol Neurotol       Date:  2016-12       Impact factor: 2.311

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.