Literature DB >> 17063005

Music perception with cochlear implants and residual hearing.

Kate E Gfeller1, Carol Olszewski, Christopher Turner, Bruce Gantz, Jacob Oleson.   

Abstract

AIM: The aims of this study were to examine the music perception abilities of Cochlear Nucleus Hybrid (acoustic plus electric stimulation) cochlear implant (CI) recipients and to compare their performance with that of normal-hearing (NH) adults and CI recipients using conventional long-electrode (LE) devices (Advanced Bionics: 90K, Clarion, CIIHF; Cochlear Corporation: CI24M, CI22, Contour; Ineraid). Hybrid CI recipients were compared with NH adults and LE CI recipients on recognition of (a) real-world melodies and (b) musical instruments. PATIENTS AND METHODS: We tested 4 Hybrid CI recipients, 17 NH adults, and 39 LE CI recipients on open-set recognition of real-world songs presented with and without lyrics. We also tested 14 Hybrid CI recipients, 21 NH adults, and 174 LE CI recipients on closed-set recognition of 8 musical instruments playing a 7-note phrase.
RESULTS: On recognition of real-world songs, both the Hybrid recipients and NH listeners were significantly more accurate (p < 0.0001) than the LE CI recipients in the no lyrics condition, which required reliance on musical cues only. The LE group was significantly less accurate than either the Hybrid or NH group (p < 0.0001) on instrument recognition for low and high frequency ranges.
CONCLUSIONS: These results, while preliminary in nature, suggest that preservation of low-frequency acoustic hearing is important for perception of real-world musical stimuli. Copyright (c) 2006 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2006        PMID: 17063005     DOI: 10.1159/000095608

Source DB:  PubMed          Journal:  Audiol Neurootol        ISSN: 1420-3030            Impact factor:   1.854


  84 in total

1.  Multicenter clinical trial of the Nucleus Hybrid S8 cochlear implant: Final outcomes.

Authors:  Bruce J Gantz; Camille Dunn; Jacob Oleson; Marlan Hansen; Aaron Parkinson; Christopher Turner
Journal:  Laryngoscope       Date:  2016-01-12       Impact factor: 3.325

2.  Using Neural Response Telemetry to Monitor Physiological Responses to Acoustic Stimulation in Hybrid Cochlear Implant Users.

Authors:  Paul J Abbas; Viral D Tejani; Rachel A Scheperle; Carolyn J Brown
Journal:  Ear Hear       Date:  2017 Jul/Aug       Impact factor: 3.570

3.  Postoperative Electrocochleography from Hybrid Cochlear Implant users: An Alternative Analysis Procedure.

Authors:  Jeong-Seo Kim; Viral D Tejani; Paul J Abbas; Carolyn J Brown
Journal:  Hear Res       Date:  2018-10-29       Impact factor: 3.208

4.  Minimum Reporting Standards for Adult Cochlear Implantation.

Authors:  Oliver F Adunka; Bruce J Gantz; Camille Dunn; Richard K Gurgel; Craig A Buchman
Journal:  Otolaryngol Head Neck Surg       Date:  2018-03-20       Impact factor: 3.497

5.  MUSIC APPRECIATION AND TRAINING FOR COCHLEAR IMPLANT RECIPIENTS: A REVIEW.

Authors:  Valerie Looi; Kate Gfeller; Virginia Driscoll
Journal:  Semin Hear       Date:  2012-11-19

Review 6.  The Hybrid cochlear implant: a review.

Authors:  Erika A Woodson; Lina A J Reiss; Christopher W Turner; Kate Gfeller; Bruce J Gantz
Journal:  Adv Otorhinolaryngol       Date:  2009-11-25

Review 7.  Psychophysical properties of low-frequency hearing: implications for perceiving speech and music via electric and acoustic stimulation.

Authors:  René H Gifford; Michael F Dorman; Christopher A Brown
Journal:  Adv Otorhinolaryngol       Date:  2009-11-25

8.  Ganglion cell and 'dendrite' populations in electric acoustic stimulation ears.

Authors:  Helge Rask-Andersen; Wei Liu; Fred Linthicum
Journal:  Adv Otorhinolaryngol       Date:  2009-11-25

9.  Temporal stability of music perception and appraisal scores of adult cochlear implant recipients.

Authors:  Kate Gfeller; Dingfeng Jiang; Jacob J Oleson; Virginia Driscoll; John F Knutson
Journal:  J Am Acad Audiol       Date:  2010-01       Impact factor: 1.664

10.  Benefits of localization and speech perception with multiple noise sources in listeners with a short-electrode cochlear implant.

Authors:  Camille C Dunn; Ann Perreau; Bruce Gantz; Richard S Tyler
Journal:  J Am Acad Audiol       Date:  2010-01       Impact factor: 1.664

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.