Literature DB >> 17049699

Complications of circular plate fixation for four-corner arthrodesis.

M K Shindle1, K J Burton, A J Weiland, B G Domb, S W Wolfe.   

Abstract

Four corner arthrodesis is an accepted salvage operation for scapholunate advanced collapse and scaphoid non-union advanced collapse. Circular plates were introduced in 1999 and promoted as a rapid and more stable method for this procedure. A retrospective chart review was performed on all patients who were treated with the Spider Limited Wrist Fusion Plate (Kinetikos Medical Inc., San Diego, CA). Sixteen patients were identified and followed clinically and with X-rays for an average of 16 (range 5-38) months. Nine out of the 16 patients (56%) had complications, including non-union (25%), delayed union (6%), dorsal impingement (25%), radial styloid impingement (6%) and broken screws (13%). The purpose of this study was to compare our complication rate using circular plates with published outcomes using traditional methods of fixation: this study identified a significantly higher complication rate and lower union rate using circular plate fixation for four-corner arthrodesis compared with previously published techniques.

Entities:  

Mesh:

Year:  2006        PMID: 17049699     DOI: 10.1016/j.jhsb.2006.08.016

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  18 in total

1.  Proximal migration of hardware in patients undergoing midcarpal fusion with headless compression screws.

Authors:  Grant D Shifflett; Edward A Athanasian; Steve K Lee; Andrew J Weiland; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2014-11

2.  Reliability of the 8 Week Time Point for Single Assessment of Midcarpal Fusion by CT Scan.

Authors:  Mark Henry
Journal:  J Hand Microsurg       Date:  2011-02-16

3.  High fusion rates with circular plate fixation for four-corner arthrodesis of the wrist.

Authors:  Ben Bedford; S Steven Yang
Journal:  Clin Orthop Relat Res       Date:  2010-01       Impact factor: 4.176

Review 4.  [(Partial) fusion of the wrist : Indications and surgical procedures].

Authors:  F Unglaub; M F Langer; J M Unglaub; M Sauerbier; L P Müller; H Krimmer; P Hahn; C K Spies
Journal:  Unfallchirurg       Date:  2017-06       Impact factor: 1.000

5.  Internal headless compression screw method for 4-corner fusion.

Authors:  Mark Henry
Journal:  J Hand Microsurg       Date:  2009-07-10

6.  Scapholunate advanced collapse (SLAC) and scaphoid nonunion advanced collapse (SNAC) wrist arthritis.

Authors:  Chirag M Shah; Peter J Stern
Journal:  Curr Rev Musculoskelet Med       Date:  2013-03

7.  Four corner fusion using a multidirectional angular stable locking plate.

Authors:  Tahseen Chaudhry; Michelle Spiteri; Dominic Power; Mark Brewster
Journal:  World J Orthop       Date:  2016-08-18

8.  Effectiveness of four-corner arthrodesis with use of a locked dorsal circular plate.

Authors:  Matthias Luegmair; Patrick Houvet
Journal:  Clin Orthop Relat Res       Date:  2012-03-20       Impact factor: 4.176

9.  The Learning Curve and Pitfalls of Arthroscopic Four-Corner Arthrodesis.

Authors:  Aleksi Vihanto; Tero Kotkansalo; Markus Pääkkönen
Journal:  J Wrist Surg       Date:  2019-02-20

10.  Four-corner fusion of the wrist: clinical and radiographic outcome of 31 patients.

Authors:  Andreas F Mavrogenis; Dimitrios A Flevas; Konstantinos Raptis; Panayiotis D Megaloikonomos; Vasilios G Igoumenou; Thekla Antoniadou; Leonidas Dimopoulos; Dimitrios Antonopoulos; Sarantis G Spyridonos
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-07-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.