Literature DB >> 27622151

Four corner fusion using a multidirectional angular stable locking plate.

Tahseen Chaudhry1, Michelle Spiteri1, Dominic Power1, Mark Brewster1.   

Abstract

AIM: To review the results of our experience with the Medartis Aptus plating system for four corner arthrodesis of the wrist, which uses a combination of compression screws and variable angle locking screws.
METHODS: We reviewed the results of 17 procedures in 16 patients that underwent scaphoid excision and four corner fusion using the Medartis Aptus system between May 2010 and June 2014. The primary outcome measure was radiographic and clinical union.
RESULTS: The mean clinical follow up time was 20.6 mo. The mean union time was 6 mo. Two non-unions required revision procedures. The mean disabilities of the arm, shoulder and hand score taken after union was 36. The mean final grip strength was 27 kg. The mean final range of movement was 30° flexion and 31° of extension. All patients had a restored scapholunate angle on postoperative radiographs. There were no incidences of dorsal impingement.
CONCLUSION: Overall our experience with the Aptus plating system shows comparable results to other methods of fixation for four corner fusion, in the short to medium term.

Entities:  

Keywords:  Arthrodesis; Locking plate; Partial fusion; Scaphoidectomy; Wrist surgery

Year:  2016        PMID: 27622151      PMCID: PMC4990772          DOI: 10.5312/wjo.v7.i8.501

Source DB:  PubMed          Journal:  World J Orthop        ISSN: 2218-5836


  13 in total

1.  Results of four-corner arthrodesis using dorsal circular plate fixation.

Authors:  Corey B Kendall; Timothy R Brown; S John Millon; L Edwin Rudisill; John L Sanders; Stephanie L Tanner
Journal:  J Hand Surg Am       Date:  2005-09       Impact factor: 2.230

2.  Complications of circular plate fixation for four-corner arthrodesis.

Authors:  M K Shindle; K J Burton; A J Weiland; B G Domb; S W Wolfe
Journal:  J Hand Surg Eur Vol       Date:  2006-10-17

3.  A method of defining palpable landmarks for the ligament-splitting dorsal wrist capsulotomy.

Authors:  Richard A Berger
Journal:  J Hand Surg Am       Date:  2007-10       Impact factor: 2.230

4.  Complications and outcome of four-corner arthrodesis: circular plate fixation versus traditional techniques.

Authors:  Michael C Vance; Jon D Hernandez; Michael L Didonna; Peter J Stern
Journal:  J Hand Surg Am       Date:  2005-11       Impact factor: 2.230

5.  Biomechanical comparison of three fixation techniques used for four-corner arthrodesis.

Authors:  J Kraisarin; D G Dennison; L J Berglund; K N An; A Y Shin
Journal:  J Hand Surg Eur Vol       Date:  2011-06-02

6.  A new plate for partial wrist fusions: results in midcarpal arthrodesis.

Authors:  D M Allison
Journal:  J Hand Surg Eur Vol       Date:  2011-01-31

7.  Scaphoid excision and 4-corner fusion using retrograde headless compression screws.

Authors:  Brandon Ball; Joseph W Bergman
Journal:  Tech Hand Up Extrem Surg       Date:  2012-12

8.  The SLAC wrist: scapholunate advanced collapse pattern of degenerative arthritis.

Authors:  H K Watson; F L Ballet
Journal:  J Hand Surg Am       Date:  1984-05       Impact factor: 2.230

9.  Scapholunate advanced collapse wrist salvage.

Authors:  D Ashmead; H K Watson; C Damon; S Herber; W Paly
Journal:  J Hand Surg Am       Date:  1994-09       Impact factor: 2.230

10.  Motion-preserving procedures in the treatment of scapholunate advanced collapse wrist: proximal row carpectomy versus four-corner arthrodesis.

Authors:  J D Wyrick; P J Stern; T R Kiefhaber
Journal:  J Hand Surg Am       Date:  1995-11       Impact factor: 2.230

View more
  4 in total

Review 1.  Update on the operative treatment of scapholunate instability for radiologists. II. Salvage procedures, total wrist arthrodesis, and total wrist arthroplasty.

Authors:  Kimia Khalatbari Kani; Hyojeong Mulcahy; Jack Porrino; Daluiski Aaron; Felix S Chew
Journal:  Skeletal Radiol       Date:  2017-05-26       Impact factor: 2.199

2.  Four-Corner Arthrodesis Using a Dedicated Dorsal Circular Plate.

Authors:  Massimo Corain; Roberta Sartore; Mara Laterza; Filippo Zanotti; Paolo Pozza; Roberto Adani
Journal:  Hand (N Y)       Date:  2020-08-26

3.  Scaphoid Excision and Bicolumnar Carpal Fusion with Retrograde Headless Screws.

Authors:  Sebastian Undurraga; Kendrick Au; Johanna Dobransky; Braden Gammon
Journal:  J Wrist Surg       Date:  2021-01-20

4.  The effect of four-corner fusion and proximal row carpectomy on uniplanar and multiplanar wrist motion: A biomechanical study.

Authors:  Stacy Fan; Clare Padmore; Assaf Kadar; Spencer Chambers; G Daniel G Langohr; Nina Suh
Journal:  J Orthop       Date:  2021-02-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.