Literature DB >> 17000099

Toward continuous glucose monitoring with planar modified biosensors and microdialysis. Study of temperature, oxygen dependence and in vivo experiment.

Francesco Ricci1, Felice Caprio, Alessandro Poscia, Francesco Valgimigli, Dimitri Messeri, Elena Lepori, Giorgio Dall'Oglio, Giuseppe Palleschi, Danila Moscone.   

Abstract

Glucose biosensors based on the use of planar screen-printed electrodes modified with an electrochemical mediator and with glucose oxidase have been optimised for their application in the continuous glucose monitoring in diabetic patients. A full study of their operative stability and temperature dependence has been accomplished, thus giving useful information for in vivo applications. The effect of dissolved oxygen concentration in the working solution was also studied in order to evaluate its effect on the linearity of the sensors. Glucose monitoring performed with serum samples was performed to evaluate the effect of matrix components on operative stability and demonstrated an efficient behaviour for 72 h of continuous monitoring. Finally, these studies led to a sensor capable of detecting glucose at concentrations as low as 0.04 mM and with a good linearity up to 2.0 mM (at 37 degrees C) with an operative stability of ca. 72 h, thus demonstrating the possible application of these sensors for continuous glucose monitoring in conjunction with a microdialysis probe. Moreover, preliminary in vivo experiments for ca. 20 h have demonstrated the feasibility of this system.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17000099     DOI: 10.1016/j.bios.2006.08.041

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  10 in total

1.  Evaluating the clinical accuracy of GlucoMen®Day: a novel microdialysis-based continuous glucose monitor.

Authors:  Francesco Valgimigli; Fausto Lucarelli; Cosimo Scuffi; Sara Morandi; Iolanda Sposato
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

2.  Comparison of the numerical and clinical accuracy of four continuous glucose monitors.

Authors:  Boris Kovatchev; Stacey Anderson; Lutz Heinemann; William Clarke
Journal:  Diabetes Care       Date:  2008-03-13       Impact factor: 19.112

Review 3.  Utilizing information technologies for lifelong monitoring in diabetes patients.

Authors:  Davide Capozzi; Giordano Lanzola
Journal:  J Diabetes Sci Technol       Date:  2011-01-01

4.  Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

Authors:  Cosimo Scuffi; Fausto Lucarelli; Francesco Valgimigli
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

5.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

Review 6.  Microdialysis techniques and microdialysis-based patient-near diagnostics.

Authors:  Mark Thomas O'Connell; Jan Krejci
Journal:  Anal Bioanal Chem       Date:  2022-01-14       Impact factor: 4.142

7.  GlucoMen Day continuous glucose monitoring system: a screening for enzymatic and electrochemical interferents.

Authors:  Fausto Lucarelli; Francesco Ricci; Felice Caprio; Francesco Valgimigli; Cosimo Scuffi; Danila Moscone; Giuseppe Palleschi
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

8.  An automated discontinuous venous blood sampling system for ex vivo glucose determination in humans.

Authors:  Roland Schaller; Franz Feichtner; Hans Köhler; Manfred Bodenlenz; Johannes Plank; Andrea Wutte; Julia K Mader; Martin Ellmerer; Reinhard Hainisch; Thomas R Pieber; Lukas Schaupp
Journal:  J Diabetes Sci Technol       Date:  2009-01

9.  Accuracy of continuous glucose monitoring during exercise in type 1 diabetes pregnancy.

Authors:  Kavita Kumareswaran; Daniela Elleri; Janet M Allen; Karen Caldwell; Marianna Nodale; Malgorzata E Wilinska; Stephanie A Amiel; Roman Hovorka; Helen R Murphy
Journal:  Diabetes Technol Ther       Date:  2013-02-27       Impact factor: 6.118

Review 10.  Italian contributions to the development of continuous glucose monitoring sensors for diabetes management.

Authors:  Giovanni Sparacino; Mattia Zanon; Andrea Facchinetti; Chiara Zecchin; Alberto Maran; Claudio Cobelli
Journal:  Sensors (Basel)       Date:  2012-10-12       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.