Literature DB >> 16961298

Measurement of intraocular pressure after LASIK by dynamic contour tonometry.

Lei Liu1, Cheng Lei, Xinyu Li, Jieyu Dong.   

Abstract

Changes of corneal properties induced by laser in situ keratomileusis (LASIK) results in low inaccurate intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT). Before and after LASIK, the applied value of IOP, measured by dynamic contour tonometry (DCT) in comparison to GAT, was evaluated. Before and 1, 4 weeks after LASIK, the IOP in 30 cases (60 eyes) was measured by GAT and DCT respectively. The obtained results were statistically processed by SPSS11.5 statistical software. The results showed that central corneal thickness (CCT) could affect GAT measurements but not DCT measurements. The comparison of IOP one and 4 weeks after LASIK revealed that the readings from GAT was separately decreased by 5.00 +/- 1.12 and 5.45 +/- 1.13 mmHg as compared with those before LASIK, while those from DCT had no significant difference. It was concluded that LASIK-induced changes of CCT could influence the accuracy of GAT measurements, but had no influence on those from DCT. DCT was more beneficial to the measurements of IOP in normal eyes and those subject to LASIK surgery.

Entities:  

Mesh:

Year:  2006        PMID: 16961298     DOI: 10.1007/bf02829580

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  12 in total

1.  Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings.

Authors:  N Feltgen; D Leifert; J Funk
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

2.  Intraocular pressure and photorefractive keratectomy: a comparison of three different tonometers.

Authors:  H J Garzozi; H S Chung; Y Lang; L Kagemann; A Harris
Journal:  Cornea       Date:  2001-01       Impact factor: 2.651

3.  The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer.

Authors:  P G Mardelli; L W Piebenga; M M Whitacre; K D Siegmund
Journal:  Ophthalmology       Date:  1997-06       Impact factor: 12.079

4.  Correction of intraocular pressure for changes in central corneal thickness following photorefractive keratectomy.

Authors:  R Munger; W G Hodge; G Mintsioulis; P J Agapitos; W B Jackson; K F Damji
Journal:  Can J Ophthalmol       Date:  1998-04       Impact factor: 1.882

5.  Tonometry after laser in situ keratomileusis treatment.

Authors:  S Duch; A Serra; J Castanera; R Abos; M Quintana
Journal:  J Glaucoma       Date:  2001-08       Impact factor: 2.503

6.  The effect of corneal thickness on applanation tonometry.

Authors:  M M Whitacre; R A Stein; K Hassanein
Journal:  Am J Ophthalmol       Date:  1993-05-15       Impact factor: 5.258

Review 7.  Sources of error with use of Goldmann-type tonometers.

Authors:  M M Whitacre; R Stein
Journal:  Surv Ophthalmol       Date:  1993 Jul-Aug       Impact factor: 6.048

8.  Ocular hypertension and central corneal thickness.

Authors:  W A Argus
Journal:  Ophthalmology       Date:  1995-12       Impact factor: 12.079

9.  Main causes of reduced intraocular pressure after excimer laser photorefractive keratectomy.

Authors:  S Patel; I M Aslanides
Journal:  J Refract Surg       Date:  1996 Sep-Oct       Impact factor: 3.573

10.  Intraocular pressure after excimer laser photorefractive keratectomy for myopia.

Authors:  I Schipper; P Senn; U Thomann; M Suppiger
Journal:  J Refract Surg       Date:  1995 Sep-Oct       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.