Literature DB >> 11189000

Intraocular pressure and photorefractive keratectomy: a comparison of three different tonometers.

H J Garzozi1, H S Chung, Y Lang, L Kagemann, A Harris.   

Abstract

PURPOSE: To evaluate the intraocular pressure (IOP) with three different instruments, Goldmann applanation tonometer (GAT), noncontact tonometer, and Tono-Pen after photorefractive keratectomy (PRK) for myopia.
METHODS: A prospective case series study to evaluate preoperative and postoperative IOP measurements of 149 eyes at 12 months. We performed GAT, noncontact tonometry, Tono-Pen central, and Tono-Pen temporal periphery measurements. We also performed measurements of the central corneal thickness (CCT) by ultrasonic pachymetry and keratometry. Pre-operative IOP reading served as control for all studies.
RESULTS: After PRK, IOP reading was significantly reduced in the treated eyes when compared with the control measurements (11.87+/-1.73 vs. 13.37+/-1.52 mm Hg, p<0.0001 with GAT; 12.07+/-1.6 vs. 13.51+/-1.59 mm Hg, p<0.0001 with noncontact tonometer; 12.18+/-1.6 vs. 13.48+/-1.55 mm Hg, p<0.0001 with Tono-Pen central; 13.48+/-1.65 vs. 13.71+/-1.56 Hg, p<0.0104 with Tono-Pen temporal periphery). There was also a significant correlation between IOP reading changes measured by GAT, noncontact tonometer, Tono-Pen central, and change of CCT and between reduction of IOP reading and keratometry (r2>0.39, p<0.0001 for each). The correlation between IOP reading change by Tono-Pen temporal periphery and CCT was also significant but r2 value was only 0.034. Tono-Pen temporal periphery postoperative IOP measurements had the best correlation with preoperative GAT IOP (r2 = 0.57, p<0.0001).
CONCLUSIONS: PRK reduced IOP reading as measured by GAT, noncontact tonometer, and Tono-Pen central; less so when measured by Tono-Pen temporal periphery. Early detection of glaucoma and IOP follow-up in glaucoma patients may be done best by peripheral Tono-Pen measurements over the nonablated cornea.

Entities:  

Mesh:

Year:  2001        PMID: 11189000     DOI: 10.1097/00003226-200101000-00006

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  10 in total

1.  Influence of post-LASIK corneal healing on scanning laser polarimetric measurement of the retinal nerve fibre layer thickness.

Authors:  G Holló; Z Z Nagy; P Vargha; I Süveges
Journal:  Br J Ophthalmol       Date:  2002-06       Impact factor: 4.638

2.  Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery.

Authors:  Antonios P Aristeidou; Georgios Labiris; Andreas Katsanos; Michalis Fanariotis; Nikitas C Foudoulakis; Vassilios P Kozobolis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-06-25       Impact factor: 3.117

3.  The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.

Authors:  P-A Tonnu; T Ho; T Newson; A El Sheikh; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

4.  Underestimation of intraocular pressure after photorefractive keratectomy: a biomechanical analysis.

Authors:  Per Hallberg; Anders Eklund; Kenneth Santala; Timo Koskela; Olof Lindahl; Christina Lindén
Journal:  Med Biol Eng Comput       Date:  2006-07-26       Impact factor: 2.602

5.  Measurement of intraocular pressure after LASIK by dynamic contour tonometry.

Authors:  Lei Liu; Cheng Lei; Xinyu Li; Jieyu Dong
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2006

6.  Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

Authors:  Shirin Hamed-Azzam; Daniel Briscoe; Oren Tomkins; Raneen Shehedeh-Mashor; Hanna Garzozi
Journal:  Int Ophthalmol       Date:  2012-12-29       Impact factor: 2.031

7.  Age differences in central and peripheral intraocular pressure using a rebound tonometer.

Authors:  J M González-Méijome; J Jorge; A Queirós; P Fernandes; R Montés-Micó; J B Almeida; M A Parafita
Journal:  Br J Ophthalmol       Date:  2006-08-02       Impact factor: 4.638

8.  The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses.

Authors:  S Boyraz; I Güngör
Journal:  Ir J Med Sci       Date:  2012-12-04       Impact factor: 1.568

9.  Glaucoma and corneal transplant procedures.

Authors:  Ammar M Al-Mahmood; Samar A Al-Swailem; Deepak P Edward
Journal:  J Ophthalmol       Date:  2012-01-18       Impact factor: 1.909

Review 10.  The Effect of Corneal Refractive Surgery on Glaucoma.

Authors:  Vassilios Kozobolis; Aristeidis Konstantinidis; Haris Sideroudi; G Labiris
Journal:  J Ophthalmol       Date:  2017-04-09       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.