Literature DB >> 16943462

Palamed G compared with Palacos R with gentamicin in Charnley total hip replacement. A randomised, radiostereometric study of 60 HIPS.

G Hallan1, A Aamodt, O Furnes, A Skredderstuen, K Haugan, L I Havelin.   

Abstract

We performed a randomised, radiostereometric study comparing two different bone cements, one of which has been sparsely clinically documented. Randomisation of 60 total hip replacements (57 patients) into two groups of 30 was undertaken. All the patients were operated on using a cemented Charnley total hip replacement, the only difference between groups being the bone cement used to secure the femoral component. The two cements used were Palamed G and Palacos R with gentamicin. The patients were followed up with repeated clinical and radiostereometric examinations for two years to assess the micromovement of the femoral component and the clinical outcome. The mean subsidence was 0.18 mm and 0.21 mm, and the mean internal rotation was 1.7 degrees and 2.0 degrees at two years for the Palamed G and Palacos R with gentamicin bone cements, respectively. We found no statistically significant differences between the groups. Micromovement occurred between the femoral component and the cement, while the cement mantle was stable inside the bone. The Harris hip score improved from a mean of 38 points (14 to 54) and 36 (10 to 57) pre-operatively to a mean of 92 (77 to 100) and 91 (63 to 100) at two years in the Palamed G and Palacos R groups, respectively. No differences were found between the groups. Both bone cements provided good initial fixation of the femoral component and good clinical results at two years.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16943462     DOI: 10.1302/0301-620X.88B9.18008

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Precision and accuracy measurement of radiostereometric analysis applied to movement of the sacroiliac joint.

Authors:  Thomas J Kibsgård; Olav Røise; Britt Stuge; Stephan M Röhrl
Journal:  Clin Orthop Relat Res       Date:  2012-06-14       Impact factor: 4.176

2.  A prospective randomised radiostereometric analysis trial of SmartSet HV and Palacos R bone cements in primary total hip arthroplasty.

Authors:  Otto S Husby; Kristin Haugan; Pål Benum; Olav A Foss
Journal:  J Orthop Traumatol       Date:  2010-03-03

3.  A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years.

Authors:  Thomas Kadar; Geir Hallan; Arild Aamodt; Kari Indrekvam; Mona Badawy; Leif Ivar Havelin; Terje Stokke; Kristin Haugan; Birgitte Espehaug; Ove Furnes
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

4.  The effect of adding tobramycin to Simplex P cement on femoral stem micromotion as measured by radiostereometric analysis: a 2-year randomized controlled trial.

Authors:  Eric Bohm; Martin Petrak; Trevor Gascoyne; Thomas Turgeon
Journal:  Acta Orthop       Date:  2012-01-17       Impact factor: 3.717

Review 5.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

6.  Palacos compared to Palamed bone cement in total hip replacement: a randomized controlled trial.

Authors:  Joris E Meinardi; Edward R Valstar; Paul Van Der Voort; Bart L Kaptein; Marta Fiocco; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2016-06-22       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.