Literature DB >> 20198403

A prospective randomised radiostereometric analysis trial of SmartSet HV and Palacos R bone cements in primary total hip arthroplasty.

Otto S Husby1, Kristin Haugan, Pål Benum, Olav A Foss.   

Abstract

BACKGROUND: Introduction of new bone cements into clinical practice should include radiostereometric studies.
MATERIALS AND METHODS: A prospective randomised radiostereometric study was performed, comparing SmartSet HV and Palacos R acrylic bone cements (without antibiotics) using third-generation cementing techniques in primary total hip arthroplasty. Thirty-five patients (36 hips) undergoing Charnley total hip arthroplasty were randomised to receive either of the two cements and were followed with repeated clinical, radiographic and radiostereometric examinations over 24 months. Twenty-seven patients (28 hips) attended 2 years postoperatively.
RESULTS: The mean distal translation observed was -0.15 mm for SmartSet HV and -0.16 mm for Palacos R. The mean rotation around the longitudinal axis was 0.9 degrees for SmartSet HV and 1.2 degrees for Palacos R. The Merle d'Aubigne Postel score was the maximum of 18 points for all patients in both groups.
CONCLUSIONS: No statistically significant difference in stem fixation with use of SmartSet HV and Palacos R was found at 2-year follow-up.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20198403      PMCID: PMC2837815          DOI: 10.1007/s10195-010-0087-x

Source DB:  PubMed          Journal:  J Orthop Traumatol        ISSN: 1590-9921


  26 in total

1.  Introducing new technology: a stepwise algorithm.

Authors:  H Malchau
Journal:  Spine (Phila Pa 1976)       Date:  2000-02-01       Impact factor: 3.468

2.  Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses.

Authors:  J Kärrholm; B Borssén; G Löwenhielm; F Snorrason
Journal:  J Bone Joint Surg Br       Date:  1994-11

3.  Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses.

Authors:  L Ryd; B E Albrektsson; L Carlsson; F Dansgård; P Herberts; A Lindstrand; L Regnér; S Toksvig-Larsen
Journal:  J Bone Joint Surg Br       Date:  1995-05

4.  A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy.

Authors:  G Selvik; P Alberius; A S Aronson
Journal:  Acta Radiol Diagn (Stockh)       Date:  1983

5.  The direct lateral approach to the hip.

Authors:  K Hardinge
Journal:  J Bone Joint Surg Br       Date:  1982

6.  Definition of endoprosthetic loosening. Comparison of arthrography, scintigraphy and roentgen stereophotogrammetry in prosthetic hips.

Authors:  B Mjöberg; J Brismar; L I Hansson; H Pettersson; G Selvik; R Onnerfält
Journal:  Acta Orthop Scand       Date:  1985-12

7.  Evaluation of a femoral stem with reduced stiffness. A randomized study with use of radiostereometry and bone densitometry.

Authors:  Johan Kärrholm; Christian Anderberg; Finnur Snorrason; Jonas Thanner; Norvald Langeland; Henrik Malchau; Peter Herberts
Journal:  J Bone Joint Surg Am       Date:  2002-09       Impact factor: 5.284

8.  Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years..

Authors:  Anna Stefánsdóttir; Herbert Franzén; Ragnar Johnsson; Ewald Ornstein; Martin Sundberg
Journal:  Acta Orthop Scand       Date:  2004-08

9.  Migration of the Charnley stem in rheumatoid arthritis and osteoarthritis. A roentgen stereophotogrammetric study.

Authors:  I Onsten; K Akesson; J Besjakov; K J Obrant
Journal:  J Bone Joint Surg Br       Date:  1995-01

10.  The classic: functional results of hip arthroplasty with acrylic prosthesis. 1954.

Authors:  R Merle d'Aubigné; M Postel
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

View more
  3 in total

Review 1.  [Bone substitute. Transplants and replacement materials--an update].

Authors:  C Rentsch; B Rentsch; D Scharnweber; H Zwipp; S Rammelt
Journal:  Unfallchirurg       Date:  2012-10       Impact factor: 1.000

Review 2.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

3.  The migration pattern of the Charnley femoral stem: a five-year follow-up RSA study in a well-functioning patient group.

Authors:  Kristin Haugan; Otto S Husby; Jomar Klaksvik; Olav A Foss
Journal:  J Orthop Traumatol       Date:  2012-05-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.