Literature DB >> 16937200

Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

D DiPietroPaolo1, H-P Müller, G Nolte, S N Erné.   

Abstract

In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA), was used for noise reduction in MCG data to improve the signal to noise ratio. Special techniques, based on statistical parameters, for identifying noise and disturbances, have been introduced to automatically eliminate noise-related and disturbance-related components before reconstructing cleaned data sets. The results show that ICA and SVD can detect and remove a variety of noise and artefact sources from MCG data, as well as from stress MCG.

Entities:  

Mesh:

Year:  2006        PMID: 16937200     DOI: 10.1007/s11517-006-0055-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

1.  Removing electroencephalographic artifacts by blind source separation.

Authors:  T P Jung; S Makeig; C Humphries; T W Lee; M J McKeown; V Iragui; T J Sejnowski
Journal:  Psychophysiology       Date:  2000-03       Impact factor: 4.016

2.  Artifact reduction in magnetoneurography based on time-delayed second-order correlations.

Authors:  A Ziehe; K R Müller; G Nolte; B M Mackert; G Curio
Journal:  IEEE Trans Biomed Eng       Date:  2000-01       Impact factor: 4.538

3.  Independent component analysis: algorithms and applications.

Authors:  A Hyvärinen; E Oja
Journal:  Neural Netw       Date:  2000 May-Jun

4.  Time course reconstruction of fetal cardiac signals from fMCG: independent component analysis versus adaptive maternal beat subtraction.

Authors:  S Comani; D Mantini; A Lagatta; F Esposito; S Di Luzio; G L Romani
Journal:  Physiol Meas       Date:  2004-10       Impact factor: 2.833

5.  A novel approach for the averaging of magnetocardiographically recorded heart beats.

Authors:  D DiPietroPaolo; H-P Müller; S N Erné
Journal:  Phys Med Biol       Date:  2005-05-05       Impact factor: 3.609

6.  Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection.

Authors:  N V Thakor; Y S Zhu
Journal:  IEEE Trans Biomed Eng       Date:  1991-08       Impact factor: 4.538

7.  Magnetocardiography and 32-lead potential mapping: repolarization in normal subjects during pharmacologically induced stress.

Authors:  K Brockmeier; L Schmitz; J D Bobadilla Chavez; M Burghoff; H Koch; R Zimmermann; L Trahms
Journal:  J Cardiovasc Electrophysiol       Date:  1997-06

8.  An information-maximization approach to blind separation and blind deconvolution.

Authors:  A J Bell; T J Sejnowski
Journal:  Neural Comput       Date:  1995-11       Impact factor: 2.026

Review 9.  Independent component analysis for biomedical signals.

Authors:  Christopher J James; Christian W Hesse
Journal:  Physiol Meas       Date:  2005-02       Impact factor: 2.833

10.  Optimal filtering and quality control of the signal-averaged ECG. High-fidelity 1-minute recordings.

Authors:  P Lander; E J Berbari; R Lazzara
Journal:  Circulation       Date:  1995-03-01       Impact factor: 29.690

View more
  7 in total

1.  The Nightingale Prize for the best scientific paper published in MBEC 2006.

Authors:  Jos A E Spaan
Journal:  Med Biol Eng Comput       Date:  2007-11-24       Impact factor: 2.602

2.  Subharmonic analysis using singular-value decomposition of ultrasound contrast agents.

Authors:  Jonathan Mamou; Jeffrey A Ketterling
Journal:  J Acoust Soc Am       Date:  2009-06       Impact factor: 1.840

3.  Independent component analysis: comparison of algorithms for the investigation of surface electrical brain activity.

Authors:  Matthias Klemm; Jens Haueisen; Galina Ivanova
Journal:  Med Biol Eng Comput       Date:  2009-02-13       Impact factor: 2.602

4.  Spatiotemporal properties of intracellular calcium signaling in osteocytic and osteoblastic cell networks under fluid flow.

Authors:  Da Jing; X Lucas Lu; Erping Luo; Paul Sajda; Pui L Leong; X Edward Guo
Journal:  Bone       Date:  2013-01-14       Impact factor: 4.398

5.  Influence of shell properties on high-frequency ultrasound imaging and drug delivery using polymer-shelled microbubbles.

Authors:  Parag V Chitnis; Sujeethraj Koppolu; Jonathan Mamou; Ceciel Chlon; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-01       Impact factor: 2.725

6.  Independent component analysis and decision trees for ECG holter recording de-noising.

Authors:  Jakub Kuzilek; Vaclav Kremen; Filip Soucek; Lenka Lhotska
Journal:  PLoS One       Date:  2014-06-06       Impact factor: 3.240

7.  Multichannel system based on a high sensitivity superconductive sensor for magnetoencephalography.

Authors:  Sara Rombetto; Carmine Granata; Antonio Vettoliere; Maurizio Russo
Journal:  Sensors (Basel)       Date:  2014-07-08       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.