Literature DB >> 15535194

Time course reconstruction of fetal cardiac signals from fMCG: independent component analysis versus adaptive maternal beat subtraction.

S Comani1, D Mantini, A Lagatta, F Esposito, S Di Luzio, G L Romani.   

Abstract

M-mode and pulsed Doppler echocardiography, cardiotocography and transabdominal fetal ECG are available in clinical practice to monitor fetal cardiac activity during advancing gestation, but none of these methods allows the direct measurement of morphological and temporal parameters for fetal rhythm assessment. Fetal magnetocardiograms (fMCGs) are noninvasive recordings of magnetic field variations associated with electrical activity of the fetal heart obtained with superconducting sensors positioned over the maternal abdomen inside a shielded room. Because of maternal cardiac activity, fMCGs are contaminated by maternal components that need to be eliminated to reconstruct fetal cardiac traces. The aim of the present work was to use two methods working in the time domain, an independent component analysis algorithm (FastICA) and an adaptive maternal beat subtraction technique (AMBS), for the retrieval of fetal cardiac signals from fMCGs. Detection rates of both methods were calculated, and FastICA and AMBS performances were compared in the context of clinical applications by estimating several temporal and morphological characteristics of the retrieved fetal traces, such as the shape and duration P-QRS-T waves, arrhythmic beat detection and classification, and noise reduction. Quantitative and qualitative comparison produced figures that always suggested that FastICA was superior to AMBS from the perspective of clinical use of the recovered fetal signals.

Entities:  

Mesh:

Year:  2004        PMID: 15535194     DOI: 10.1088/0967-3334/25/5/019

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

Authors:  D DiPietroPaolo; H-P Müller; G Nolte; S N Erné
Journal:  Med Biol Eng Comput       Date:  2006-05-03       Impact factor: 2.602

2.  Segmented independent component analysis for improved separation of fetal cardiac signals from nonstationary fetal magnetocardiograms.

Authors:  Luiz O Murta; Mauro G Guzo; Eder R Moraes; Oswaldo Baffa; Ronald T Wakai; Silvia Comani
Journal:  Biomed Tech (Berl)       Date:  2015-06       Impact factor: 1.411

3.  A new ICA-based fingerprint method for the automatic removal of physiological artifacts from EEG recordings.

Authors:  Gabriella Tamburro; Patrique Fiedler; David Stone; Jens Haueisen; Silvia Comani
Journal:  PeerJ       Date:  2018-02-23       Impact factor: 2.984

4.  Invariant heart beat span versus variant heart beat intervals and its application to fetal ECG extraction.

Authors:  Huawen Yan; Hongxing Liu; Xiaolin Huang; Ying Zhao; Junfeng Si; Tiebing Liu
Journal:  Biomed Eng Online       Date:  2014-12-12       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.