Literature DB >> 16937181

The influence of coincidence of fetal and maternal QRS complexes on fetal heart rate reliability.

Adam Matonia1, Janusz Jezewski, Tomasz Kupka, Krzysztof Horoba, Janusz Wrobel, Adam Gacek.   

Abstract

Bioelectrical fetal heart activity being recorded from maternal abdominal surface contains more information than mechanical heart activity measurement based on the Doppler ultrasound signals. However, it requires extraction of fetal electrocardiogram from abdominal signals where the maternal electrocardiogram is dominant. The simplest technique for maternal component suppression is a blanking procedure, which relies upon the replacement of maternal QRS complexes by isoline values. Although, in case of coincidence of fetal and maternal QRS complexes, it causes a loss of information on fetal heart activity. Its influence on determination of fetal heart rate and the variability analysis depends on the sensitivity of the heart-beat detector used. The sensitivity is defined as an ability to detect the incomplete fetal QRS complex. The aim of this work was to evaluate the influence of the maternal electrocardiogram suppression method used on the reliability of FHR signal being calculated.

Mesh:

Year:  2006        PMID: 16937181     DOI: 10.1007/s11517-006-0054-0

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  10 in total

1.  Compact long-term recorder for the transabdominal foetal and maternal electrocardiogram.

Authors:  J F Piéri; J A Crowe; B R Hayes-Gill; C J Spencer; K Bhogal; D K James
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

Review 2.  Monitoring the fetal heart non-invasively: a review of methods.

Authors:  M Peters; J Crowe; J F Piéri; H Quartero; B Hayes-Gill; D James; J Stinstra; S Shakespeare
Journal:  J Perinat Med       Date:  2001       Impact factor: 1.901

3.  The principles of software QRS detection.

Authors:  Bert-Uwe Köhler; Carsten Hennig; Reinhold Orglmeister
Journal:  IEEE Eng Med Biol Mag       Date:  2002 Jan-Feb

4.  Comparison of doppler ultrasound and direct electrocardiography acquisition techniques for quantification of fetal heart rate variability.

Authors:  Janusz Jezewski; Janusz Wrobel; Krzysztof Horoba
Journal:  IEEE Trans Biomed Eng       Date:  2006-05       Impact factor: 4.538

5.  Comparison of SVD methods to extract the foetal electrocardiogram from cutaneous electrode signals.

Authors:  D Callaerts; B De Moor; J Vandewalle; W Sansen; G Vantrappen; J Janssens
Journal:  Med Biol Eng Comput       Date:  1990-05       Impact factor: 2.602

6.  A comparison of the noise sensitivity of nine QRS detection algorithms.

Authors:  G M Friesen; T C Jannett; M A Jadallah; S L Yates; S R Quint; H T Nagle
Journal:  IEEE Trans Biomed Eng       Date:  1990-01       Impact factor: 4.538

7.  Fetal ECG extraction from single-channel maternal ECG using singular value decomposition.

Authors:  P P Kanjilal; S Palit; G Saha
Journal:  IEEE Trans Biomed Eng       Date:  1997-01       Impact factor: 4.538

8.  A real-time QRS detection algorithm.

Authors:  J Pan; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1985-03       Impact factor: 4.538

9.  A new technique for the suppression of the MECG.

Authors:  P Bergveld; W J Meijer
Journal:  IEEE Trans Biomed Eng       Date:  1981-04       Impact factor: 4.538

10.  Abdominal-lead fetal electrocardiographic R-wave enhancement for heart rate determination.

Authors:  S Azevedo; R L Longini
Journal:  IEEE Trans Biomed Eng       Date:  1980-05       Impact factor: 4.538

  10 in total
  11 in total

1.  CSE database: extended annotations and new recommendations for ECG software testing.

Authors:  Radovan Smíšek; Lucie Maršánová; Andrea Němcová; Martin Vítek; Jiří Kozumplík; Marie Nováková
Journal:  Med Biol Eng Comput       Date:  2016-12-31       Impact factor: 2.602

2.  Noninvasive Fetal ECG: the PhysioNet/Computing in Cardiology Challenge 2013.

Authors:  Ikaro Silva; Joachim Behar; Reza Sameni; Tingting Zhu; Julien Oster; Gari D Clifford; George B Moody
Journal:  Comput Cardiol (2010)       Date:  2013-03

3.  Single-lead noninvasive fetal ECG extraction by means of combining clustering and principal components analysis.

Authors:  Yue Zhang; Shuai Yu
Journal:  Med Biol Eng Comput       Date:  2019-12-19       Impact factor: 2.602

4.  Extraction of fetal electrocardiogram using H(infinity) adaptive algorithms.

Authors:  Sadasivan Puthusserypady
Journal:  Med Biol Eng Comput       Date:  2007-08-21       Impact factor: 2.602

5.  Non-invasive fetal ECG analysis.

Authors:  Gari D Clifford; Ikaro Silva; Joachim Behar; George B Moody
Journal:  Physiol Meas       Date:  2014-07-29       Impact factor: 2.833

6.  Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms.

Authors:  Radek Martinek; Radana Kahankova; Homer Nazeran; Jaromir Konecny; Janusz Jezewski; Petr Janku; Petr Bilik; Jan Zidek; Jan Nedoma; Marcel Fajkus
Journal:  Sensors (Basel)       Date:  2017-05-19       Impact factor: 3.576

7.  Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

Authors:  Janusz Jezewski; Janusz Wrobel; Adam Matonia; Krzysztof Horoba; Radek Martinek; Tomasz Kupka; Michal Jezewski
Journal:  Front Physiol       Date:  2017-05-16       Impact factor: 4.566

8.  Fetal electrocardiograms, direct and abdominal with reference heartbeat annotations.

Authors:  Adam Matonia; Janusz Jezewski; Tomasz Kupka; Michał Jezewski; Krzysztof Horoba; Janusz Wrobel; Robert Czabanski; Radana Kahankowa
Journal:  Sci Data       Date:  2020-06-25       Impact factor: 6.444

9.  Comparative Effectiveness of ICA and PCA in Extraction of Fetal ECG From Abdominal Signals: Toward Non-invasive Fetal Monitoring.

Authors:  Radek Martinek; Radana Kahankova; Janusz Jezewski; Rene Jaros; Jitka Mohylova; Marcel Fajkus; Jan Nedoma; Petr Janku; Homer Nazeran
Journal:  Front Physiol       Date:  2018-05-30       Impact factor: 4.566

Review 10.  Non-Adaptive Methods for Fetal ECG Signal Processing: A Review and Appraisal.

Authors:  Rene Jaros; Radek Martinek; Radana Kahankova
Journal:  Sensors (Basel)       Date:  2018-10-27       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.