Literature DB >> 16686408

Comparison of doppler ultrasound and direct electrocardiography acquisition techniques for quantification of fetal heart rate variability.

Janusz Jezewski1, Janusz Wrobel, Krzysztof Horoba.   

Abstract

A method for comparison of two acquisition techniques that are applied in clinical practice to provide information on fetal condition is presented. The aim of this work was to evaluate the commonly used Doppler ultrasound technique for monitoring of mechanical activity of fetal heart. Accuracy of beat-to-beat interval determination together with its influence on indices describing the fetal heart rate (FHR) variability calculated automatically using computer-aided fetal monitoring system were examined. We considered the direct fetal electrocardiography as a reference technique because it ensures the highest possible accuracy of heart interval measurement, and additionally all the definitions of popular time domain parameters quantifying FHR variability formerly have been created using the fetal electrocardiogram. We evaluated the reliability of various so called short-term and long-term variability indices, when they are calculated automatically using the signal obtained via the Doppler US from a fetal monitor. The results proved that evaluation of the acquisition technique influence on fetal well-being assessment can not be accomplished basing on direct measurements of heartbeats only. The more relevant is the estimation of accuracy of the variability indices, since analysis of their changes can significantly increase predictability of fetal distress.

Mesh:

Year:  2006        PMID: 16686408     DOI: 10.1109/TBME.2005.863945

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  13 in total

1.  The influence of coincidence of fetal and maternal QRS complexes on fetal heart rate reliability.

Authors:  Adam Matonia; Janusz Jezewski; Tomasz Kupka; Krzysztof Horoba; Janusz Wrobel; Adam Gacek
Journal:  Med Biol Eng Comput       Date:  2006-04-12       Impact factor: 2.602

2.  An adaptive integrated algorithm for noninvasive fetal ECG separation and noise reduction based on ICA-EEMD-WS.

Authors:  Guangchen Liu; Yihui Luan
Journal:  Med Biol Eng Comput       Date:  2015-10-01       Impact factor: 2.602

3.  A novel technique for fetal heart rate estimation from Doppler ultrasound signal.

Authors:  Janusz Jezewski; Dawid Roj; Janusz Wrobel; Krzysztof Horoba
Journal:  Biomed Eng Online       Date:  2011-10-14       Impact factor: 2.819

4.  Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms.

Authors:  Radek Martinek; Radana Kahankova; Homer Nazeran; Jaromir Konecny; Janusz Jezewski; Petr Janku; Petr Bilik; Jan Zidek; Jan Nedoma; Marcel Fajkus
Journal:  Sensors (Basel)       Date:  2017-05-19       Impact factor: 3.576

5.  Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

Authors:  Janusz Jezewski; Janusz Wrobel; Adam Matonia; Krzysztof Horoba; Radek Martinek; Tomasz Kupka; Michal Jezewski
Journal:  Front Physiol       Date:  2017-05-16       Impact factor: 4.566

6.  A Phonocardiographic-Based Fiber-Optic Sensor and Adaptive Filtering System for Noninvasive Continuous Fetal Heart Rate Monitoring.

Authors:  Radek Martinek; Jan Nedoma; Marcel Fajkus; Radana Kahankova; Jaromir Konecny; Petr Janku; Stanislav Kepak; Petr Bilik; Homer Nazeran
Journal:  Sensors (Basel)       Date:  2017-04-18       Impact factor: 3.576

7.  A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience.

Authors:  Ning Tian; Weiyuan Zhang
Journal:  Biomed Res Int       Date:  2018-05-17       Impact factor: 3.411

8.  Fetal electrocardiograms, direct and abdominal with reference heartbeat annotations.

Authors:  Adam Matonia; Janusz Jezewski; Tomasz Kupka; Michał Jezewski; Krzysztof Horoba; Janusz Wrobel; Robert Czabanski; Radana Kahankowa
Journal:  Sci Data       Date:  2020-06-25       Impact factor: 6.444

Review 9.  Fetal ECG extraction from abdominal signals: a review on suppression of fundamental power line interference component and its harmonics.

Authors:  Dragoş-Daniel Ţarălungă; Georgeta-Mihaela Ungureanu; Ilinca Gussi; Rodica Strungaru; Werner Wolf
Journal:  Comput Math Methods Med       Date:  2014-02-09       Impact factor: 2.238

10.  New estimators and guidelines for better use of fetal heart rate estimators with Doppler ultrasound devices.

Authors:  Iulian Voicu; Sébastien Ménigot; Denis Kouamé; Jean-Marc Girault
Journal:  Comput Math Methods Med       Date:  2014-01-29       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.