Monitoring the fetal heart non-invasively: a review of methods.

M Peters1, J Crowe, J F Piéri, H Quartero, B Hayes-Gill, D James, J Stinstra, S Shakespeare.   

Abstract

Doppler ultrasound, ultrasound M-mode analysis, fetal electrocardiography, and fetal magnetocardiography are methods by which the fetal heart can be monitored non-invasively. In this paper, they are evaluated and compared. Customarily, it is solely the fetal heart rate, which is monitored using the Doppler ultrasound technique since it is both simple to use and cheap. However, this method inherently produces an averaged heart rate and therefore cannot give the beat-to-beat variability. Fetal electrocardiography has similar advantages, but in addition offers the potential for monitoring beat-to-beat variability and performing electrocardiogram morphological analysis. Its disadvantage is that its reliability is only 60%, although it is the only technique that offers truly long-term ambulatory monitoring. Ultrasound M-mode analysis allows a estimation of atrial and ventricular coordination, as well as an estimation of PR intervals. Bradycardias, supraventricular tachycardias, extra systoles are readily diagnosed using this method although timing will be inaccurate. Fetal magnetocardiograms can be detected reliably and used for accurate beat-to-beat measurements and morphological analysis. Consequently, they can be used for the classification of arrhythmias and the diagnosis of a long QT syndrome and some congenital heart diseases.

Entities:  

Mesh:

Year:  2001        PMID: 11723842     DOI: 10.1515/JPM.2001.057

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  30 in total

1.  The influence of coincidence of fetal and maternal QRS complexes on fetal heart rate reliability.

Authors:  Adam Matonia; Janusz Jezewski; Tomasz Kupka; Krzysztof Horoba; Janusz Wrobel; Adam Gacek
Journal:  Med Biol Eng Comput       Date:  2006-04-12       Impact factor: 2.602

2.  Permutation entropy improves fetal behavioural state classification based on heart rate analysis from biomagnetic recordings in near term fetuses.

Authors:  B Frank; B Pompe; U Schneider; D Hoyer
Journal:  Med Biol Eng Comput       Date:  2006-03-17       Impact factor: 2.602

3.  Prospective cardiac motion self-gating.

Authors:  Fei Han; Stanislas Rapacchi; Peng Hu
Journal:  Quant Imaging Med Surg       Date:  2017-04

4.  A Review of Fetal ECG Signal Processing; Issues and Promising Directions.

Authors:  Reza Sameni; Gari D Clifford
Journal:  Open Pacing Electrophysiol Ther J       Date:  2010-01-01

5.  Assessment of fetal atrioventricular time intervals by tissue Doppler and pulse Doppler echocardiography: normal values and correlation with fetal electrocardiography.

Authors:  M Nii; R M Hamilton; L Fenwick; J C P Kingdom; K S Roman; E T Jaeggi
Journal:  Heart       Date:  2006-06-14       Impact factor: 5.994

6.  Coupling Analysis of Fetal and Maternal Heart Rates via Transfer Entropy Using Magnetocardiography.

Authors:  R Avci; D Escalona-Vargas; E R Siegel; C L Lowery; H Eswaran
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

Review 7.  Cardiotocography and beyond: a review of one-dimensional Doppler ultrasound application in fetal monitoring.

Authors:  Faezeh Marzbanrad; Lisa Stroux; Gari D Clifford
Journal:  Physiol Meas       Date:  2018-08-14       Impact factor: 2.833

Review 8.  The Critical Role of the Central Autonomic Nervous System in Fetal-Neonatal Transition.

Authors:  Sarah B Mulkey; Adre Dú Plessis
Journal:  Semin Pediatr Neurol       Date:  2018-06-20       Impact factor: 1.636

9.  An mHealth monitoring system for traditional birth attendant-led antenatal risk assessment in rural Guatemala.

Authors:  Lisa Stroux; Boris Martinez; Enma Coyote Ixen; Nora King; Rachel Hall-Clifford; Peter Rohloff; Gari D Clifford
Journal:  J Med Eng Technol       Date:  2016-10-04

10.  Cardiac vectors in the healthy human fetus: developmental changes assessed by magnetocardiography and realistic approximations of the volume conductor.

Authors:  R Tao; E A Popescu; W B Drake; M Popescu
Journal:  Physiol Meas       Date:  2013-04-22       Impact factor: 2.833

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.