Literature DB >> 16928932

Dose reduction and image quality in MDCT colonography using tube current modulation.

A Graser1, B J Wintersperger, C Suess, M F Reiser, C R Becker.   

Abstract

OBJECTIVE: The purpose of our study was to evaluate the dose reduction potential of combined online (x- and y-axes) and topogram-based (l) X-ray tube current modulation in CT colonography in a screening population.
MATERIALS AND METHODS: Eighty asymptomatic individuals underwent CT colonography screening for colon polyps. A 16-MDCT scanner (Somatom Sensation 16) was used. Forty patients were examined at 120 kVp and 120 effective mAs (supine) and 40 effective mAs (prone) using online x- and y-axis tube current modulation. Another 40 patients were scanned using combined x-, y-, and z-axis tube current modulation. Individual patient radiation exposure was determined using the dose-length product. Image noise was determined by Hounsfield unit measurements in the colonic lumen at four anatomic levels. Image quality was rated on a 5-point confidence scale by two independent reviewers. The unpaired Student's t test (for radiation dose, image noise) and Wilcoxon's test (for image quality) were used to test for statistically significant differences between these values.
RESULTS: Radiation dose was significantly lower in the patient group scanned with x-, y-, and z-axis tube current modulation than in the group scanned with x- and y-axis tube current modulation (supine: 4.24 vs 6.50 mSv, p < 0.0001; prone: 1.61 vs 2.38 mSv, p < 0.0001). Radiation dose was reduced by 35% (supine) and 33% (prone). No statistically significant difference was seen in overall image noise (supine: 15.9 vs 16.3 H, p = 0.13; prone: 23.5 vs 24.8 H, p = 0.44) or image quality (supine: 4.6 vs 4.5, p = 0.62; prone: 3.5 vs 3.6, p = 0.54).
CONCLUSION: Combined x-, y-, and z-axis tube current modulation leads to a significant reduction of radiation exposure in CT colonography without loss of image quality.

Entities:  

Mesh:

Year:  2006        PMID: 16928932     DOI: 10.2214/AJR.05.0662

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  33 in total

1.  Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Authors:  Gaurav S Desai; Raul N Uppot; Elaine W Yu; Avinash R Kambadakone; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

2.  Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

Authors:  Hyun Kyong Lim; Kyoung Ho Lee; So Yeon Kim; Kil Joong Kim; Bohyoung Kim; Hyunna Lee; Seong Ho Park; Jeffrey H Yanof; Seung-Sik Hwang; Young Hoon Kim
Journal:  Eur Radiol       Date:  2010-08-11       Impact factor: 5.315

3.  Comparison of diagnostic accuracy and interpretation times for a standard and an advanced 3D visualisation technique in CT colonography.

Authors:  Thomas Mang; Frank T Kolligs; Claus Schaefer; Maxmilian F Reiser; Anno Graser
Journal:  Eur Radiol       Date:  2010-10-03       Impact factor: 5.315

4.  Evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction with the same group of patients.

Authors:  L-P Qi; Y Li; L Tang; Y-L Li; X-T Li; Y Cui; Y-S Sun; X-P Zhang
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

5.  [CT colonography: patient preparation and examination technique].

Authors:  P Lefere; S Gryspeerdt; T Mang
Journal:  Radiologe       Date:  2008-02       Impact factor: 0.635

Review 6.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

7.  Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation.

Authors:  U Lechel; C Becker; G Langenfeld-Jäger; G Brix
Journal:  Eur Radiol       Date:  2008-11-06       Impact factor: 5.315

8.  CT dose and image quality in the last three scanner generations.

Authors:  Andreas Christe; Johannes Heverhagen; Christoph Ozdoba; Christian Weisstanner; Stefan Ulzheimer; Lukas Ebner
Journal:  World J Radiol       Date:  2013-11-28

Review 9.  Computed tomography colonography in 2014: an update on technique and indications.

Authors:  Andrea Laghi
Journal:  World J Gastroenterol       Date:  2014-12-07       Impact factor: 5.742

Review 10.  CT colonography for population screening: ready for prime time?

Authors:  Perry J Pickhardt
Journal:  Dig Dis Sci       Date:  2014-12-10       Impact factor: 3.199