Literature DB >> 16919507

Arterial versus capillary blood gases: a meta-analysis.

Gerald S Zavorsky1, Jiguo Cao, Nancy E Mayo, Rina Gabbay, Juan M Murias.   

Abstract

A meta-analysis determined whether capillary blood gases accurately reflect arterial blood samples. A mixed effects model was used on 29 relevant studies obtained from a PubMed/Medline search. From 664 and 222 paired samples obtained from the earlobe and fingertip, respectively, earlobe compared to fingertip sampling shows that the standard deviation of the difference is about 2.5x less (or the precision is 2.5x better) in resembling arterial PO(2) over a wide range of arterial PO(2)'s (21-155 mm Hg ). The lower the arterial PO(2), the more accurate it is when predicting arterial PO(2) from any capillary sample (p<0.05). However, while earlobe sampling predicts arterial PO(2) (adjusted r(2)=0.88, mean bias=3.8 mm Hg compared to arterial), fingertip sampling does not (adjusted r(2)=0.48, mean bias=11.5 mm Hg compared to arterial). Earlobe sampling is slightly more accurate compared to fingertip sampling in resembling arterial PCO(2) (arterial versus earlobe, adjusted r(2)=0.94, mean bias=1.9 mm Hg ; arterial versus fingertip, adjusted r(2)=0.95, mean bias=2.2 mm Hg compared to arterial) but both sites can closely reflect arterial PCO(2) (880 total paired samples, range 10-114 mm Hg ). No real difference between sampling from the earlobe or fingertip were found for pH as both sites accurately reflect arterial pH over a wide range of pH (587 total paired samples, range 6.77-7.74, adjusted r(2)=0.90-0.94, mean bias=0.02). In conclusion, sampling blood from the fingertip or earlobe (preferably) accurately reflects arterial PCO(2) and pH over a wide range of values. Sampling blood, too, from earlobe (but never the fingertip) may be appropriate as a replacement for arterial PO(2), unless precision is required as the residual standard error is 6 mm Hg when predicting arterial PO(2) from an earlobe capillary sample.

Mesh:

Substances:

Year:  2006        PMID: 16919507     DOI: 10.1016/j.resp.2006.07.002

Source DB:  PubMed          Journal:  Respir Physiol Neurobiol        ISSN: 1569-9048            Impact factor:   1.931


  58 in total

1.  ARTP statement on pulmonary function testing 2020.

Authors:  Karl Peter Sylvester; Nigel Clayton; Ian Cliff; Michael Hepple; Adrian Kendrick; Jane Kirkby; Martin Miller; Alan Moore; Gerrard Francis Rafferty; Liam O'Reilly; Joanna Shakespeare; Laurie Smith; Trefor Watts; Martyn Bucknall; Keith Butterfield
Journal:  BMJ Open Respir Res       Date:  2020-07

2.  Non-invasive carbon dioxide monitoring in patients with cystic fibrosis during general anesthesia: end-tidal versus transcutaneous techniques.

Authors:  Anne May; Chris Humston; Julie Rice; Christopher J Nemastil; Ann Salvator; Joseph Tobias
Journal:  J Anesth       Date:  2019-11-07       Impact factor: 2.078

3.  Relationship of acid-base status with arterial stiffness in community-living elders: the Health ABC Study.

Authors:  Wei Chen; Anne B Newman; Linda F Fried; Dena E Rifkin; Michael G Shlipak; Mark J Sarnak; Ronit Katz; Magdalena Madero; Kalani L Raphael; David A Bushinsky; Joachim H Ix
Journal:  Nephrol Dial Transplant       Date:  2018-09-01       Impact factor: 5.992

4.  Significance of Patent Foramen Ovale in Patients with GOLD Stage II Chronic Obstructive Pulmonary Disease (COPD).

Authors:  Dario Martolini; Rebecca Tanner; Claire Davey; Mehul S Patel; Davide Elia; Helen Purcell; Paolo Palange; Nicholas S Hopkinson; Michael I Polkey
Journal:  Chronic Obstr Pulm Dis       Date:  2014-09-25

5.  Evaluation of the Microstat™ sublingual PCO2 monitor in ambulatory patients.

Authors:  Benjamin D Fox; Dominique Joyal; Robert D Schlesinger; Mark J Eisenberg; David Langleben
Journal:  J Clin Monit Comput       Date:  2015-03-10       Impact factor: 2.502

Review 6.  [Functional diagnostics in pneumology].

Authors:  M Held; S Baron; B Jany
Journal:  Internist (Berl)       Date:  2018-01       Impact factor: 0.743

Review 7.  Methods and analyzers for hemoglobin measurement in clinical laboratories and field settings.

Authors:  Ralph D Whitehead; Zuguo Mei; Carine Mapango; Maria Elena D Jefferds
Journal:  Ann N Y Acad Sci       Date:  2019-06-04       Impact factor: 5.691

8.  Polysomnographic differences associated with pulmonary hypertension in patients with advanced lung disease due to cystic fibrosis.

Authors:  Don Hayes; Curt J Daniels; Stephen Kirkby; Benjamin T Kopp; Kerri L Nicholson; Ashley E Nance; Mark L Splaingard
Journal:  Lung       Date:  2014-03-27       Impact factor: 2.584

9.  Long-term gas exchange characteristics as markers of deterioration in patients with cystic fibrosis.

Authors:  Richard Kraemer; Philipp Latzin; Isabelle Pramana; Pietro Ballinari; Sabina Gallati; Urs Frey
Journal:  Respir Res       Date:  2009-11-12

10.  Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine.

Authors:  Richard B Berry; Rohit Budhiraja; Daniel J Gottlieb; David Gozal; Conrad Iber; Vishesh K Kapur; Carole L Marcus; Reena Mehra; Sairam Parthasarathy; Stuart F Quan; Susan Redline; Kingman P Strohl; Sally L Davidson Ward; Michelle M Tangredi
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.