The usefulness of computed tomography following open reduction and internal fixation of acetabular fractures.

K O'Shea1, J F Quinlan, K Waheed, O H Brady.   

Abstract

PURPOSE: To investigate the role of a supplemental imaging modality in postoperative assessment of acetabular fractures following open reduction and internal fixation.
METHODS: Postoperative axial computed tomographic (CT) scans were compared with plain radiographs of 20 patients with regard to their sensitivity for detecting articular fracture reduction in terms of gap displacement and step deformity or offset. Three observers independently reviewed the plain radiographs and CT scans at 2 separate time points and categorised the outcome as either anatomical or non-anatomical. The inter-observer reliability and intra-observer reproducibility of these measurements was expressed as a kappa statistic. The radiological result was correlated with the clinical outcome measures using the Merle D'Aubigne scale, the Harris Hip Score, and the SF-36 score.
RESULTS: Plain radiography was less effective in the detection of postoperative articular displacement (mean, 75.1% sensitive). The inter-observer and intra-observer agreement between reviewers was good to excellent in detecting reduction quality between the 2 modalities. Patient management was not altered by the findings of the CT scans.
CONCLUSIONS: Although postoperative CT scanning of acetabular fractures in selective cases may be useful, issues such as higher cost, less effective allocation of resources, and excessive radiation doses do not support its routine use.

Entities:  

Mesh:

Year:  2006        PMID: 16914774     DOI: 10.1177/230949900601400204

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  5 in total

1.  Assessment of two 3-D fluoroscopic systems for articular fracture reduction: a cadaver study.

Authors:  Yoram A Weil; Meir Liebergall; Rami Mosheiff; Syndie B Singer; Leo Joskowicz; Amal Khoury
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-02-06       Impact factor: 2.924

2.  Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation?

Authors:  L Maini; A Sharma; S Jha; A Sharma; A Tiwari
Journal:  Eur J Trauma Emerg Surg       Date:  2016-10-26       Impact factor: 3.693

3.  Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture.

Authors:  Chun-Chi Hung; Yuan-Ta Li; Yu-Ching Chou; Jia-En Chen; Chia-Chun Wu; Hsain-Chung Shen; Tsu-Te Yeh
Journal:  Int Orthop       Date:  2018-05-03       Impact factor: 3.075

4.  What Are the Interobserver and Intraobserver Variability of Gap and Stepoff Measurements in Acetabular Fractures?

Authors:  Anne M L Meesters; Kaj Ten Duis; Hester Banierink; Vincent M A Stirler; Philip C R Wouters; Joep Kraeima; Jean-Paul P M de Vries; Max J H Witjes; Frank F A IJpma
Journal:  Clin Orthop Relat Res       Date:  2020-12       Impact factor: 4.755

5.  The accuracy of gap and step-off measurements in acetabular fracture treatment.

Authors:  A M L Meesters; K Ten Duis; J Kraeima; H Banierink; V M A Stirler; P C R Wouters; J P P M de Vries; M J H Witjes; F F A IJpma
Journal:  Sci Rep       Date:  2021-09-14       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.