Literature DB >> 16911424

Accuracy of LED and halogen radiometers using different light sources.

Howard W Roberts1, Kraig S Vandewalle, David W Berzins, David G Charlton.   

Abstract

PURPOSE: To determine the accuracy of commercially available, handheld light-emitting diode (LED) and halogen-based radiometers using LED and quartz-tungsten-halogen (QTH) curing lights with light guides of various diameters.
METHODS: The irradiance of an LED curing light (L.E. Demetron 1, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory-grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two-way analysis of variance/Tukey; alpha = 0.05.
RESULTS: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger-diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller-diameter light guides tended to underestimate. CLINICAL SIGNIFICANCE: The evaluated LED or halogen handheld radiometers may be used interchangeably to determine the irradiance of both LED and QTH visible-light-curing units. Measured differences between the two radiometer types were small and probably not clinically significant. However, the diameter of light guides may affect the accuracy of the radiometers, with larger-diameter light guides overestimating and smaller-diameter guides underestimating the irradiance value measured by the control instrument.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16911424     DOI: 10.1111/j.1708-8240.2006.00023.x

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  11 in total

1.  Influence of physical assessment of different light-curing units on irradiance and composite microhardness top/bottom ratio.

Authors:  Susana Morimoto; Renata Aló Maluza Zanini; Josete Barbosa Cruz Meira; Carlos Martins Agra; Fernanda Calabró Calheiros; Denis Yudi Nagase
Journal:  Odontology       Date:  2016-01-13       Impact factor: 2.634

2.  A survey of power density of light-curing units used in private dental offices in Changchun City, China.

Authors:  Xinqing Hao; Meng Luo; Jian Wu; Song Zhu
Journal:  Lasers Med Sci       Date:  2013-05-23       Impact factor: 3.161

3.  Evaluation of light-curing units in rural and urban areas.

Authors:  Maan M Alshaafi
Journal:  Saudi Dent J       Date:  2012-08-04

4.  Intra- and inter-brand accuracy of four dental radiometers.

Authors:  Richard Bengt Price; Daniel Labrie; Sonya Kazmi; John Fahey; Christopher M Felix
Journal:  Clin Oral Investig       Date:  2011-05-12       Impact factor: 3.573

5.  A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra.

Authors:  Vivek Hegde; Sameer Jadhav; Gayatri B Aher
Journal:  J Conserv Dent       Date:  2009-07

6.  Comparative study of surface microhardness of methacrylate-based composite resins polymerized with light-emitting diodes and halogen.

Authors:  Camila Sabatini
Journal:  Eur J Dent       Date:  2013-07

7.  Light intensity output of visible light communication units and clinicians' knowledge and attitude among Riyadh private clinics.

Authors:  Lama Mana Alqabbaa; Mounira Sami Alsenani; Norah Saad Alsaif; Ruba Abdulrahman Alsaif; Sultan Rukayb Binalrimal
Journal:  J Conserv Dent       Date:  2018 Nov-Dec

8.  Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips.

Authors:  Marília Regalado Galvão; Sergei Godeiro Fernandes Rabelo Caldas; Vanderlei Salvador Bagnato; Alessandra Nara de Souza Rastelli; Marcelo Ferrarezi de Andrade
Journal:  Eur J Dent       Date:  2013-01

9.  Effect of emitted wavelength and light guide type on irradiance discrepancies in hand-held dental curing radiometers.

Authors:  Atsushi Kameyama; Akiko Haruyama; Masako Asami; Toshiyuki Takahashi
Journal:  ScientificWorldJournal       Date:  2013-10-10

Review 10.  Assessing Dental Light-curing Units' Output Using Radiometers: A Narrative Review.

Authors:  Cendrella Assaf; Jean-Claude Fahd; Joseph Sabbagh
Journal:  J Int Soc Prev Community Dent       Date:  2020-01-24
View more