Literature DB >> 16883011

Clinically significant abnormal findings on the "nondiagnostic" CT portion of low-amperage-CT attenuation-corrected myocardial perfusion SPECT/CT studies.

Sibyll Goetze1, Harpreet K Pannu, Richard L Wahl.   

Abstract

UNLABELLED: Attenuation correction is recommended to optimize the performance of cardiac SPECT. The 2.5-mA CT commonly used for this purpose in myocardial perfusion SPECT is generally considered "nondiagnostic" in quality. In other areas of cardiac and hybrid imaging, diagnostically relevant abnormal findings on higher-quality CT studies have been described. The purpose of this study was to establish the frequency and significance of abnormal findings on low-amperage-CT cardiac SPECT/CT scans and to assess whether a systematic review of the nondiagnostic CT findings should be recommended.
METHODS: Two hundred consecutive patients who underwent clinical low-amperage-CT attenuation-corrected myocardial perfusion studies acquired on a SPECT/CT system were included in the study. The cardiac CT images were reviewed in consensus by both an experienced CT reader and a nuclear medicine resident less experienced in CT. Abnormal CT findings of varying significance were recorded.
RESULTS: Eighty-one patients had no abnormal CT findings. In the remaining 119 patients, 234 abnormalities were detected. Twenty-five major findings (in 21 patients) were seen, and 16 of these had been previously unrecognized. Sixty-four minor and 131 minimal findings were noted. Fourteen findings were labeled as equivocal (i.e., the CT findings were not definite).
CONCLUSION: Potentially significant abnormal findings on the nondiagnostic-CT portion of the cardiac SPECT/CT examination were detected in 10.5% of our patients. These data suggest that, in addition to the review of the emission image dataset, low-amperage-CT findings should routinely be assessed for major diagnostic abnormalities.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16883011

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  15 in total

1.  Prevalence of noncardiac findings on low dose 64-slice computed tomography used for attenuation correction in myocardial perfusion imaging with SPECT.

Authors:  Lars Husmann; Fuminari Tatsugami; Ursina Aepli; Bernhard A Herzog; Ines Valenta; Patrick Veit-Haibach; Ronny R Buechel; Aju P Pazhenkottil; Oliver Gaemperli; Nina Burkhard; Christophe A Wyss; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2009-08-07       Impact factor: 2.357

2.  Incidental findings on hybrid SPECT-CT and PET-CT scanners: Is it time for new training and reporting guidelines?

Authors:  Steven Port
Journal:  J Nucl Cardiol       Date:  2018-04-12       Impact factor: 5.952

3.  Multi-centre analysis of incidental findings on low-resolution CT attenuation correction images.

Authors:  J Coward; R Lawson; T Kane; M Elias; A Howes; J Birchall; P Hogg
Journal:  Br J Radiol       Date:  2014-08-19       Impact factor: 3.039

4.  Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC).

Authors:  Albert Flotats; Juhani Knuuti; Matthias Gutberlet; Claudio Marcassa; Frank M Bengel; Philippe A Kaufmann; Michael R Rees; Birger Hesse
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01       Impact factor: 9.236

5.  Radiological profile of anemia on unenhanced MDCT of the thorax.

Authors:  Ehab M Kamel; Elena Rizzo; Michel A Duchosal; Rafael Duran; Vasco Goncalves-Matoso; Pierre Schnyder; Salah D Qanadli
Journal:  Eur Radiol       Date:  2008-04-02       Impact factor: 5.315

6.  Multicentre analysis of incidental findings on low-resolution CT attenuation correction images: an extended study.

Authors:  Joanne Coward; Richard Lawson; Tom Kane; Mark Elias; Andrea Howes; James Birchall; Peter Hogg
Journal:  Br J Radiol       Date:  2015-10-23       Impact factor: 3.039

7.  A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings: a phantom study.

Authors:  John D Thompson; Peter Hogg; David J Manning; Katy Szczepura; Dev P Chakraborty
Journal:  Acad Radiol       Date:  2014-04       Impact factor: 3.173

8.  Optimisation of protocol for low dose CT-derived attenuation correction in myocardial perfusion SPECT imaging.

Authors:  Rainer Preuss; Reiner Weise; Oliver Lindner; Eva Fricke; Harald Fricke; Wolfgang Burchert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-12       Impact factor: 9.236

9.  Prevalence of clinically significant extraosseous findings on unenhanced CT portions of ¹⁸F-fluoride PET/CT bone scans.

Authors:  Chao-Jung Chen; Shih-Ya Ma
Journal:  ScientificWorldJournal       Date:  2012-09-10

10.  Incidental Findings of Pulmonary and Hilar Malignancy by Low-Resolution Computed Tomography Used in Myocardial Perfusion Imaging.

Authors:  Robert T Tung; Johannes Heyns; Lynne Dryer
Journal:  Fed Pract       Date:  2020-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.