Literature DB >> 32952384

Incidental Findings of Pulmonary and Hilar Malignancy by Low-Resolution Computed Tomography Used in Myocardial Perfusion Imaging.

Robert T Tung1, Johannes Heyns1, Lynne Dryer1.   

Abstract

BACKGROUND: Low dose, low-resolution computed tomography (CT) is used for attenuation correction to improve the quality of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Because of its low resolution, these CT images are considered non-diagnostic and are not routinely or uniformly reviewed or interpreted by a cardiologist. On the other hand, low-dose CT has been used for lung cancer screening to reduce lung cancer mortality and is recommended for annual screening of high-risk patients by the US Preventive Services Task Force.
METHODS: Siemens Symbia Intevo Excel SPECT/CT scanners, used primarily for cardiac MPI, were used in the study. The study was intended to report incidental findings of pulmonary and hilar malignancy detected by these CT images during cardiac evaluation. It included 1,098 consecutive patients who had SPECT MPI from September 1, 2017 to August 31, 2018. When suspicious pulmonary nodules or abnormalities were identified, primary care providers were notified of the findings and recommendations for further evaluation.
RESULTS: Five patients were found to have lung cancer (all male with substantial smoking history, aged 64-75 years), 1 had mantle cell lymphoma. Six of 1,098 (0.55%) patients were found to have incidental pulmonary/hilar malignancy, which is comparable to the yield (0.65%/year) of detecting lung cancer using low-dose CT for screening in The National Lung Screening Trial.
CONCLUSIONS: Routine review and report of incidental findings on low-resolution CT during cardiac MPI by physicians skilled in CT interpretation is necessary to identify incidental but clinically important findings, including malignancies.
Copyright © 2020 Frontline Medical Communications Inc., Parsippany, NJ, USA.

Entities:  

Year:  2020        PMID: 32952384      PMCID: PMC7497876     

Source DB:  PubMed          Journal:  Fed Pract        ISSN: 1078-4497


  25 in total

1.  The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine.

Authors:  Robert C Hendel; James R Corbett; S James Cullom; E Gordon DePuey; Ernest V Garcia; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

Review 2.  The pros and cons of searching for extracardiac findings at cardiac CT: studies should be reconstructed in the maximum field of view and adequately reviewed to detect pathologic findings.

Authors:  James P Earls
Journal:  Radiology       Date:  2011-11       Impact factor: 11.105

3.  Clinically significant abnormal findings on the "nondiagnostic" CT portion of low-amperage-CT attenuation-corrected myocardial perfusion SPECT/CT studies.

Authors:  Sibyll Goetze; Harpreet K Pannu; Richard L Wahl
Journal:  J Nucl Med       Date:  2006-08       Impact factor: 10.057

4.  Coronary artery imaging with contrast-enhanced MDCT: extracardiac findings.

Authors:  Sabine Haller; Christoph Kaiser; Peter Buser; Georg Bongartz; Jens Bremerich
Journal:  AJR Am J Roentgenol       Date:  2006-07       Impact factor: 3.959

Review 5.  The Clinical Dilemma of Incidental Findings on the Low-Resolution CT Images from SPECT/CT MPI Studies.

Authors:  Joanne Coward; Julie Nightingale; Peter Hogg
Journal:  J Nucl Med Technol       Date:  2016-04-21

6.  ASNC imaging guidelines/SNMMI procedure standard for positron emission tomography (PET) nuclear cardiology procedures.

Authors:  Vasken Dilsizian; Stephen L Bacharach; Rob S Beanlands; Steven R Bergmann; Dominique Delbeke; Sharmila Dorbala; Robert J Gropler; Juhani Knuuti; Heinrich R Schelbert; Mark I Travin
Journal:  J Nucl Cardiol       Date:  2016-07-08       Impact factor: 5.952

7.  Reduced lung-cancer mortality with low-dose computed tomographic screening.

Authors:  Denise R Aberle; Amanda M Adams; Christine D Berg; William C Black; Jonathan D Clapp; Richard M Fagerstrom; Ilana F Gareen; Constantine Gatsonis; Pamela M Marcus; JoRean D Sicks
Journal:  N Engl J Med       Date:  2011-06-29       Impact factor: 91.245

8.  Multicentre analysis of incidental findings on low-resolution CT attenuation correction images: an extended study.

Authors:  Joanne Coward; Richard Lawson; Tom Kane; Mark Elias; Andrea Howes; James Birchall; Peter Hogg
Journal:  Br J Radiol       Date:  2015-10-23       Impact factor: 3.039

9.  Screening for lung cancer: U.S. Preventive Services Task Force recommendation statement.

Authors:  Virginia A Moyer
Journal:  Ann Intern Med       Date:  2014-03-04       Impact factor: 25.391

Review 10.  Malignant incidental extracardiac findings on cardiac CT: systematic review and meta-analysis.

Authors:  Nicola Flor; Giovanni Di Leo; Silvia Amaryllis Claudia Squarza; Silvia Tresoldi; Eliana Rulli; Gianpaolo Cornalba; Francesco Sardanelli
Journal:  AJR Am J Roentgenol       Date:  2013-09       Impact factor: 3.959

View more
  2 in total

1.  Incidental renal masses on SPECT/CT and PET/CT.

Authors:  Jorge D Oldan; Amir H Khandani
Journal:  Am J Nucl Med Mol Imaging       Date:  2022-06-15

2.  Incidental Findings of Malignancy of the Chest by Single Photon Emission Computed Tomography Myocardial Perfusion Imaging (SPECT-CT MPI): One Year Follow-Up Report.

Authors:  Robert T Tung; Johannes Heyns
Journal:  Kans J Med       Date:  2020-11-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.