Water equivalent plastic scintillation detectors in radiation therapy.

A S Beddar1.   

Abstract

A review of the dosimetric characteristics and properties of plastic scintillation detectors for use in radiation therapy is presented. The detectors show many desirable qualities when exposed to megavoltage photon and electron beams, including water equivalence, energy independence, reproducibility, dose linearity, resistance to radiation damage and near temperature independence. These detectors do not require the usual conversion and/or correction factors used to convert the readings from common dosemeters to absorbed dose. Due to their small detecting volume, plastic scintillation detectors exhibit excellent spatial resolution. Detector performance, in certain specific cases, can be affected by radiation-induced light arising in the optical fibres that carry the scintillator signal to a photodetector. While this effect is negligible for photon beams, it may not be ignored for electron beams and needs to be accounted for.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16882685     DOI: 10.1093/rpd/nci694

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  9 in total

1.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.

Authors:  Sam Beddar; Louis Archambault; Narayan Sahoo; Falk Poenisch; George T Chen; Michael T Gillin; Radhe Mohan
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

3.  Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.

Authors:  Francois Lessard; Louis Archambault; Mathieu Plamondon; Philippe Despres; Franccois Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

4.  Toward a real-time in vivo dosimetry system using plastic scintillation detectors.

Authors:  Louis Archambault; Tina M Briere; Falk Pönisch; Luc Beaulieu; Deborah A Kuban; Andrew Lee; Sam Beddar
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-16       Impact factor: 7.038

5.  Polyethylene Naphthalate Scintillator: A Novel Detector for the Dosimetry of Radioactive Ophthalmic Applicators.

Authors:  Dirk Flühs; Andrea Flühs; Melanie Ebenau; Marion Eichmann
Journal:  Ocul Oncol Pathol       Date:  2015-06-06

6.  Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer.

Authors:  Landon Wootton; Rajat Kudchadker; Andrew Lee; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

7.  Preliminary evaluation of the dosimetric accuracy of the in vivo plastic scintillation detector OARtrac system for prostate cancer treatments.

Authors:  Slade J Klawikowski; Clint Zeringue; Landon S Wootton; Geoffrey S Ibbott; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

8.  Integral T-shaped phantom-dosimeter system to measure transverse and longitudinal dose distributions simultaneously for stereotactic radiosurgery dosimetry.

Authors:  Wook Jae Yoo; Jinsoo Moon; Kyoung Won Jang; Ki-Tek Han; Sang Hun Shin; Dayeong Jeon; Jang-Yeon Park; Byung Gi Park; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2012-05-14       Impact factor: 3.576

Review 9.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.