Measurement of head scatter factors of linear accelerators with columnar miniphantoms.

Paul A Jursinic1.   

Abstract

The measurement of linear accelerator head scatter factors or in-air output factors, Sc, with columnar miniphantoms is refined in this work. Columnar miniphantoms are constructed from water equivalent materials: solid water and M3, and materials with higher mass density and atomic number: copper and lead. The change in the value of Sc from a 4-cm X 4-cm to a 40-cm X 40-cm field is different by 22% +/- 3%, 18% +/- 2%, and 10% +/- 3% for 6, 15, and 23 MV x rays, respectively, when measured with water equivalent or lead miniphantoms of 10 gm/cm2 depth. Based on measurements of transmission factors in solid-water miniphantoms of different depths, it is demonstrated that the beam energy spectra decreases in energy with increased field size. These changes in beam energy spectra alter the transmission and scatter of radiation and buildup of the dose in the miniphantom even if the miniphantom is made of water-equivalent material. These changes underlie the alteration in Sc when measured by miniphantoms fabricated from materials of different atomic number. It is shown that miniphantoms designed with a depth just adequate to stop contamination electrons will minimize these distortions due to transmission and scatter of radiation and buildup of dose in the miniphantom. Use of a miniphantom constructed from water-equivalent material with a depth appropriate for the x-ray energy being measured is the preferred method for determining Sc for dosimetry in water.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16872079     DOI: 10.1118/1.2201148

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Measurement and comparison of head scatter factor for 7 MV unflattened (FFF) and 6 MV flattened photon beam using indigenously designed columnar mini phantom.

Authors:  Sigamani Ashokkumar; Arunai Nambiraj; Sujit Nath Sinha; Girigesh Yadav; Kothanda Raman; Manindra Bhushan; Rajesh Thiyagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2015-03-01

2.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  Commissioning an Elekta Versa HD linear accelerator.

Authors:  Ganesh Narayanasamy; Daniel Saenz; Wilbert Cruz; Chul S Ha; Niko Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

4.  Effect of Material and Wall Thickness Buildup Caps on the Head Scatter Factor Measurements in Irregular Fields Shielded by Cerrobend.

Authors:  Ali Jomehzadeh; Daryoush Shahbazi-Gahrouei; Vahid Jahanbakhsh
Journal:  J Med Signals Sens       Date:  2017 Oct-Dec

5.  Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions.

Authors:  Parinaz Mehnati; Farideh Biglari; Ali Jomehzadeh
Journal:  J Med Signals Sens       Date:  2019 Apr-Jun

6.  Comparison of Head Scatter Factor for 6MV and 10MV flattened (FB) and Unflattened (FFF) Photon Beam using indigenously Designed Columnar Mini Phantom.

Authors:  Sigamani Ashokkumar; N Arunai Nambi Raj; Sujit Nath Sinha; Girigesh Yadav; Rajesh Thiyagarajan; Kothanda Raman; Manindra Bhushan Mishra
Journal:  J Med Phys       Date:  2014-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.