Literature DB >> 16864237

Reliability of an infrared forehead skin thermometer for core temperature measurements.

J A Kistemaker1, E A Den Hartog, H A M Daanen.   

Abstract

The SensorTouch thermometer performs an infrared measurement of the skin temperature above the Superficial Temporal Artery (STA). This study evaluates the validity and the accuracy of the SensorTouch thermometer. Two experiments were performed in which the body temperature was measured with a rectal sensor, with an oesophageal sensor and with the SensorTouch. After entering a warm chamber the SensorTouch underestimated the core temperature during the first 10 minutes. After that, the SensorTouch was not significantly different from the core temperature, with an average difference of 0.5 degrees C (SD 0.5 degrees C) in the first study and 0.3 degrees C (SD 0.2 degrees C) in the second study. The largest differences between the SensorTouch and the core temperature existed 15 minutes after the start of the exercise. During this period the SensorTouch was significantly higher than the core temperature. The SensorTouch did not provide reliable values of the body temperature during periods of increasing body temperature, but the SensorTouch might work under stable conditions.

Mesh:

Year:  2006        PMID: 16864237     DOI: 10.1080/03091900600711381

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  13 in total

1.  Bioharness(™) multivariable monitoring device: part. I: validity.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

2.  Validity and reliability of devices that assess body temperature during indoor exercise in the heat.

Authors:  Matthew S Ganio; Christopher M Brown; Douglas J Casa; Shannon M Becker; Susan W Yeargin; Brendon P McDermott; Lindsay M Boots; Paul W Boyd; Lawrence E Armstrong; Carl M Maresh
Journal:  J Athl Train       Date:  2009 Mar-Apr       Impact factor: 2.860

3.  Temporal Artery versus Bladder Thermometry during Adult Medical-Surgical Intensive Care Monitoring: An Observational Study.

Authors:  Henry T Stelfox; Sharon E Straus; William A Ghali; John Conly; Kevin Laupland; Adriane Lewin
Journal:  BMC Anesthesiol       Date:  2010-08-12       Impact factor: 2.217

4.  Validity of devices that assess body temperature during outdoor exercise in the heat.

Authors:  Douglas J Casa; Shannon M Becker; Matthew S Ganio; Christopher M Brown; Susan W Yeargin; Melissa W Roti; Jason Siegler; Julie A Blowers; Neal R Glaviano; Robert A Huggins; Lawrence E Armstrong; Carl M Maresh
Journal:  J Athl Train       Date:  2007 Jul-Sep       Impact factor: 2.860

5.  Evaluation of performance and uncertainty of infrared tympanic thermometers.

Authors:  Wenbin Chung; Chiachung Chen
Journal:  Sensors (Basel)       Date:  2010-03-31       Impact factor: 3.576

6.  Non-invasive Measures of Core Temperature versus Ingestible Thermistor during Exercise in the Heat.

Authors:  Donovan L Fogt; Andrea L Henning; Adam S Venable; Brian K McFarlin
Journal:  Int J Exerc Sci       Date:  2017-03-01

7.  Relationship between Tongue Temperature Estimated by Infrared Thermography, Tongue Color, and Cold-Heat Pathological Patterns: A Retrospective Chart Review Study.

Authors:  Seung-Won Baek; Jin-Moo Lee; Young-Bae Park; Young-Jae Park
Journal:  Evid Based Complement Alternat Med       Date:  2018-05-27       Impact factor: 2.629

8.  Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites.

Authors:  Hsuan-Yu Chen; Andrew Chen; Chiachung Chen
Journal:  Sensors (Basel)       Date:  2020-05-19       Impact factor: 3.576

9.  Evaluation of the Cadi ThermoSENSOR wireless skin-contact thermometer against ear and axillary temperatures in children.

Authors:  Kim-Gau Ng; Sook-Thow Wong; Soh-Min Lim; Zenton Goh
Journal:  J Pediatr Nurs       Date:  2009-04-18       Impact factor: 2.145

10.  Hearables: New Perspectives and Pitfalls of In-Ear Devices for Physiological Monitoring. A Scoping Review.

Authors:  Michela Masè; Alessandro Micarelli; Giacomo Strapazzon
Journal:  Front Physiol       Date:  2020-10-16       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.