Standing versus supine radiographs in RSA evaluation of femoral head penetration.

Charles R Bragdon1, Jonas Thanner, Meridith E Greene, Henrik Malchau, Georgios Digas, William H Harris, Johan Kärrholm.   

Abstract

Evaluation of polyethylene acetabular component wear in total hip arthroplasties commonly is performed using serial radiographs of the hip by measuring the change in the location of the center of the femoral head in relation to the acetabular component. Of the different methods currently used for this purpose, radiostereometric analysis (RSA) is considered the most accurate and precise. In all such radiographic studies, it is assumed the femoral head is seated into the deepest portion of the acetabular component during all radiographic examinations. Although most radiographs used for wear measurements are taken with the patient supine, we questioned whether standing radiographs, with substantial joint load, are better suited for these measurements. We evaluated two groups of patients having total hip arthroplasty who had radiostereometric radiographs taken in supine and standing positions. The average femoral head penetration that occurred between the 6-month and 2-year time interval was measured with radiographs taken in the standing or supine position. We found no difference between the average total femoral head penetration when using supine or standing radiographs.

Entities:  

Mesh:

Year:  2006        PMID: 16826095     DOI: 10.1097/01.blo.0000224012.50292.67

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Case report: Cementless stem stabilization after intraoperative fracture: a radiostereometric analysis.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2009-09-17       Impact factor: 4.176

2.  Second-generation highly cross-linked X3™ polyethylene wear: a preliminary radiostereometric analysis study.

Authors:  David G Campbell; John R Field; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2010-02-12       Impact factor: 4.176

3.  Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty.

Authors:  Caroline Scemama; Claudio Dora; Jean Langlois; Moussa Hamadouche
Journal:  Int Orthop       Date:  2014-12-04       Impact factor: 3.075

4.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

Review 5.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

Review 6.  Wear of highly crosslinked polyethylene acetabular components.

Authors:  Stuart A Callary; Lucian B Solomon; Oksana T Holubowycz; David G Campbell; Zachary Munn; Donald W Howie
Journal:  Acta Orthop       Date:  2014-10-10       Impact factor: 3.717

7.  No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear, and clinical outcome.

Authors:  Michiel J M Minten; Petra J C Heesterbeek; Maarten Spruit
Journal:  Acta Orthop       Date:  2016-06-14       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.