Literature DB >> 25472754

Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty.

Caroline Scemama1, Claudio Dora, Jean Langlois, Moussa Hamadouche.   

Abstract

PURPOSE: Highly cross-linked polyethylenes (PE) have been developed with encouraging results in terms of wear. Another body of the literature has indicated potential catastrophic failures related to reduced fatigue properties and oxidation. Each PE available on the market has its own processing characteristics. The aim of this retrospective study was to evaluate the minimum five-year wear properties of an original highly cross-linked PE in a consecutive series of primary THAs.
METHODS: Between August 2005 and December 2007, 80 patients with a mean age of 62.7 years were included. All patients had a 28-mm CoCr femoral head articulating with a highly cross-linked insert (Highcross®, Medacta SA) that was 100 Mrads gamma radiated, remelted at 150 °C, and ethylene oxide sterilized. The primary criterion for evaluation was the femoral head penetration, as measured by Hip Analysis Suite software. The steady state wear was also calculated. Functional results were evaluated according to the WOMAC score.
RESULTS: Complete data were available for analysis in 67 patients at a mean follow-up of 5.5 years. The mean femoral head penetration was 0.128 ± 0.62 mm and the steady state wear was-0.025 ± 0.22 mm/year. The WOMAC score significantly decreased from 16.5 ± 5.93 pre-operatively to 4.12 ± 5.5 at the latest follow-up (p <0.001).
CONCLUSIONS: The minimal five-year results of this retrospective study indicate that this particular highly cross-linked and remelted polyethylene had a low wear rate. Longer-term results are needed to warrant that these mid-term data will generate less osteolysis and resultant aseptic loosening.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25472754     DOI: 10.1007/s00264-014-2609-2

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners.

Authors:  Letitia Bradford; David A Baker; Jove Graham; Arun Chawan; Michael D Ries; Lisa A Pruitt
Journal:  J Bone Joint Surg Am       Date:  2004-06       Impact factor: 5.284

2.  Minimum 5-year wear analysis of first-generation highly cross-linked polyethylene in patients 65 years and younger.

Authors:  Amar S Ranawat; Panagiotis Tsailis; Morteza Meftah; Trevor W Koob; Jose A Rodriguez; Chitranjan S Ranawat
Journal:  J Arthroplasty       Date:  2011-12-15       Impact factor: 4.757

3.  In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals.

Authors:  Keith K Wannomae; Shayan Bhattacharyya; Andrew Freiberg; Daniel Estok; William H Harris; Orhun Muratoglu
Journal:  J Arthroplasty       Date:  2006-07-17       Impact factor: 4.757

4.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

5.  Early polyethylene wear and osteolysis in cementless total hip arthroplasty: the influence of femoral head size and polyethylene thickness.

Authors:  P C Lee; C H Shih; W J Chen; Y K Tu; C L Tai
Journal:  J Arthroplasty       Date:  1999-12       Impact factor: 4.757

6.  The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.

Authors:  Geraint E R Thomas; David J Simpson; Shahid Mehmood; Adrian Taylor; Peter McLardy-Smith; Harinderjit Singh Gill; David W Murray; Siôn Glyn-Jones
Journal:  J Bone Joint Surg Am       Date:  2011-04-20       Impact factor: 5.284

7.  A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial.

Authors:  P Triclot; G Grosjean; F El Masri; J P Courpied; M Hamadouche
Journal:  J Bone Joint Surg Br       Date:  2007-11

8.  5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis.

Authors:  Georgios Digas; Johan Kärrholm; Jonas Thanner; Peter Herberts
Journal:  Acta Orthop       Date:  2007-12       Impact factor: 3.717

9.  Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.

Authors:  Richard W McCalden; Steven J MacDonald; Cecil H Rorabeck; Robert B Bourne; David G Chess; Kory D Charron
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

Review 10.  Over 25 years survival after Charnley's total hip arthroplasty.

Authors:  Jacques Caton; Jean Louis Prudhon
Journal:  Int Orthop       Date:  2011-01-21       Impact factor: 3.075

View more
  3 in total

Review 1.  Acetabular reinforcement rings associated with allograft for severe acetabular defects.

Authors:  Emmanuel Gibon; Luc Kerboull; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2018-09-13       Impact factor: 3.075

2.  Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements.

Authors:  Harman Khatkar; Harry Hothi; Danielle de Villiers; Christian Lausmann; Daniel Kendoff; Thorsten Gehrke; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-10-25       Impact factor: 3.075

3.  Thirteen-year wear rate comparison of highly crosslinked and conventional polyethylene in total hip arthroplasty: long-term follow-up of a prospective randomized controlled trial.

Authors:  Matthew G Teeter; Xunhua Yuan; Lyndsay E Somerville; Steven J MacDonald; Richard W McCalden; Douglas D Naudie
Journal:  Can J Surg       Date:  2017-06       Impact factor: 2.089

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.