BACKGROUND: There are few dual X-ray absorptiometry (DXA) studies on periacetabular bone density changes after cup implantation. This study was designed to analyze the load-transfer mechanism and stress pattern of periacetabular cortical and cancellous bone after implantation of a ihemispherical titanium alloy press-fit cup with alumina-alumina pairing in vivo. We introduced a novel method of computed tomography (CT)-assisted osteodensitometry. METHOD: We investigated 26 hips (26 patients) with osteoarthritis using conventional sequential CT examinations performed within the first 10 days after implantation, and after a mean period of 1.1 years postoperatively. Bone density of full, cancellous and cortical bone (mgCaHA/mL) was measured. RESULTS: At the time of follow-up, the mean bone density values of the cortical bone cranial to the cup increased by 3.6% (p = 0.03) while the cancellous bone density decreased by 18%. Cancellous bone loss was greater in the region ventral to the cup (-35%) than in the dorsal region (-30%). Cortical bone density decreased ventral to the cup (-6.4%). All these changes were statistically significant. The bone density changes in the dorsal cortical region were not significant. INTERPRETATION: The method presented is an excellent tool for detailed measurement of bone density changes around the cup after total hip arthroplasty, and allows a thorough assessment of stress shielding phenomena in vivo. The hemispherical titanium alloy press-fit cup is a rigid implant which stress shields cancellous bone and enhances load transfer to the cranial cortical bone. Further investigations will demonstrate the impact these factors have on the long-term results of the implant, and may allow a type-related predictable prognosis of the longevity of the prosthesis.
BACKGROUND: There are few dual X-ray absorptiometry (DXA) studies on periacetabular bone density changes after cup implantation. This study was designed to analyze the load-transfer mechanism and stress pattern of periacetabular cortical and cancellous bone after implantation of a ihemispherical titanium alloy press-fit cup with alumina-alumina pairing in vivo. We introduced a novel method of computed tomography (CT)-assisted osteodensitometry. METHOD: We investigated 26 hips (26 patients) with osteoarthritis using conventional sequential CT examinations performed within the first 10 days after implantation, and after a mean period of 1.1 years postoperatively. Bone density of full, cancellous and cortical bone (mgCaHA/mL) was measured. RESULTS: At the time of follow-up, the mean bone density values of the cortical bone cranial to the cup increased by 3.6% (p = 0.03) while the cancellous bone density decreased by 18%. Cancellous bone loss was greater in the region ventral to the cup (-35%) than in the dorsal region (-30%). Cortical bone density decreased ventral to the cup (-6.4%). All these changes were statistically significant. The bone density changes in the dorsal cortical region were not significant. INTERPRETATION: The method presented is an excellent tool for detailed measurement of bone density changes around the cup after total hip arthroplasty, and allows a thorough assessment of stress shielding phenomena in vivo. The hemispherical titanium alloy press-fit cup is a rigid implant which stress shields cancellous bone and enhances load transfer to the cranial cortical bone. Further investigations will demonstrate the impact these factors have on the long-term results of the implant, and may allow a type-related predictable prognosis of the longevity of the prosthesis.
Authors: Lutz A Mueller; Tobias E Nowak; Lothar Haeberle; Lars P Mueller; Alexander Kress; Michael Voelk; David Pfander; Raimund Forst; Rainer Schmidt Journal: Acta Orthop Date: 2010-04 Impact factor: 3.717
Authors: Masako Tsukanaka; Vera Halvorsen; Lars Nordsletten; Ingvild Ø EngesæTer; Lars B EngesæTer; Anne Marie Fenstad; Stephan M Röhrl Journal: Acta Orthop Date: 2016-07-20 Impact factor: 3.717