Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas.

Shinji Ichimori1, Kenro Nishida, Seiya Shimoda, Taiji Sekigami, Yasuto Matsuo, Kenshi Ichinose, Motoaki Shichiri, Michiharu Sakakida, Eiichi Araki.   

Abstract

To produce a long-life, stable, miniature glucose sensor for a wearable artificial endocrine pancreas (WAEP), we developed a novel microneedle-type glucose sensor using polyimide, designated the PI sensor (outer diameter, 0.3 mm; length, 16 mm), and investigated its characteristics in vitro and in vivo. In the in vitro study, we tested the sensor in 0.9% NaCl solution with varying glucose concentrations and observed an excellent linear relationship between the sensor output and glucose concentration (range: 0-500 mg/100 ml). In in vivo experiments, the PI sensor was inserted into the abdominal subcutaneous tissue of beagle dogs (n = 5), and interstitial fluid glucose concentrations were monitored after sensor calibration. Simultaneously, blood glucose concentrations were also monitored continuously with another PI sensor placed intravenously. The correlation and time delay between subcutaneous tissue glucose (Y) and blood glucose concentrations (X: 30-350 mg/100 ml) were Y = 1.03X + 7.98 (r = 0.969) and 6.6 +/- 1.2 min, respectively. We applied the new WAEP system/PI sensor and an intravenous insulin infusion algorithm developed previously for glycemic control in diabetic dogs. The use of the WAEP system resulted in excellent glycemic control after an oral glucose challenge of 1.5 g/kg (post-challenge blood glucose levels: 176 +/- 18 mg/100 ml at 65 min and 93 +/- 23 mg/100 ml at 240 min), without any hypoglycemia. Thus, we confirmed that our new PI sensor has excellent sensor characteristics in vitro and in vivo. The new WAEP using this sensor is potentially suitable for clinical application.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16807813     DOI: 10.1007/s10047-005-0326-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  40 in total

1.  Transdermal monitoring of glucose and other analytes using ultrasound.

Authors:  J Kost; S Mitragotri; R A Gabbay; M Pishko; R Langer
Journal:  Nat Med       Date:  2000-03       Impact factor: 53.440

Review 2.  The MiniMed Continuous Glucose Monitoring System (CGMS).

Authors:  J Mastrototaro
Journal:  J Pediatr Endocrinol Metab       Date:  1999       Impact factor: 1.634

Review 3.  The GlucoWatch biographer: a frequent automatic and noninvasive glucose monitor.

Authors:  M J Tierney; J A Tamada; R O Potts; R C Eastman; K Pitzer; N R Ackerman; S J Fermi
Journal:  Ann Med       Date:  2000-12       Impact factor: 4.709

4.  Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring.

Authors:  D S Bindra; Y Zhang; G S Wilson; R Sternberg; D R Thévenot; D Moatti; G Reach
Journal:  Anal Chem       Date:  1991-09-01       Impact factor: 6.986

Review 5.  Can interstitial glucose assessment replace blood glucose measurements?

Authors:  K Rebrin; G M Steil
Journal:  Diabetes Technol Ther       Date:  2000       Impact factor: 6.118

6.  Kinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3-mm amperometric microsensors.

Authors:  C P Quinn; M V Pishko; D W Schmidtke; M Ishikawa; J G Wagner; P Raskin; J A Hubbell; A Heller
Journal:  Am J Physiol       Date:  1995-07

7.  Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method. Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients.

Authors:  Y Hashiguchi; M Sakakida; K Nishida; T Uemura; K Kajiwara; M Shichiri
Journal:  Diabetes Care       Date:  1994-05       Impact factor: 19.112

8.  Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes.

Authors:  S K Garg; R O Potts; N R Ackerman; S J Fermi; J A Tamada; H P Chase
Journal:  Diabetes Care       Date:  1999-10       Impact factor: 19.112

9.  In vivo subcutaneous adipose tissue glucose kinetics after glucose ingestion in obesity and fasting.

Authors:  E Hagström; P Arner; P Engfeldt; S Rössner; J Bolinder
Journal:  Scand J Clin Lab Invest       Date:  1990-04       Impact factor: 1.713

10.  Glucose content in human skin: relationship with blood glucose levels.

Authors:  B M Jensen; P Bjerring; J S Christiansen; H Orskov
Journal:  Scand J Clin Lab Invest       Date:  1995-08       Impact factor: 1.713

View more
  7 in total

1.  Journal of Artificial Organs 2006: the year in review.

Authors:  Y Sawa; T Horiuchi; A Kishida; T Masuzawa; M Nishimura; E Tatsumi; Y Tomizawa; H Watanabe
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

2.  Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range.

Authors:  Linda Morrow; Marcus Hompesch; Ann M Tideman; Jennifer Matson; Nancy Dunne; Scott Pardo; Joan L Parkes; Holly C Schachner; David A Simmons
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

3.  Electrodeposition of chitosan-glucose oxidase biocomposite onto Pt-Pb nanoparticles modified stainless steel needle electrode for amperometric glucose biosensor.

Authors:  Meiqing Guo; Haidong Fang; Rui Wang; Zhiqiang Yang; Xinhua Xu
Journal:  J Mater Sci Mater Med       Date:  2011-06-14       Impact factor: 3.896

Review 4.  Wearable and implantable pancreas substitutes.

Authors:  Leonardo Ricotti; Tareq Assaf; Paolo Dario; Arianna Menciassi
Journal:  J Artif Organs       Date:  2012-09-20       Impact factor: 1.731

Review 5.  Recent progress in mechanical artificial pancreas.

Authors:  Masami Hoshino; Yoshikura Haraguchi; Iwanori Mizushima; Motohiro Sakai
Journal:  J Artif Organs       Date:  2009-09-19       Impact factor: 1.731

Review 6.  What is artificial endocrine pancreas? Mechanism and history.

Authors:  Kenro Nishida; Seiya Shimoda; Kenshi Ichinose; Eiichi Araki; Motoaki Shichiri
Journal:  World J Gastroenterol       Date:  2009-09-07       Impact factor: 5.742

7.  An Electronic Health Record-Integrated Computerized Intravenous Insulin Infusion Protocol: Clinical Outcomes and in Silico Adjustment.

Authors:  Sung Woon Park; Seunghyun Lee; Won Chul Cha; Kyu Yeon Hur; Jae Hyeon Kim; Moon Kyu Lee; Sung Min Park; Sang Man Jin
Journal:  Diabetes Metab J       Date:  2019-10-21       Impact factor: 5.376

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.