Literature DB >> 19894087

Recent progress in mechanical artificial pancreas.

Masami Hoshino1, Yoshikura Haraguchi, Iwanori Mizushima, Motohiro Sakai.   

Abstract

Strict blood glucose (BG) control is proved to improve the outcome in patients with glucose intolerance both in acute and chronic phases, irrespective of whether the patient has diabetes mellitus. However, strict BG control by conventional methods is so complicated that it cannot be performed easily in normal clinical situations. Furthermore, it is sometimes inadequate. Therefore, a clinically applicable, reliable artificial pancreas (AP) has long been sought after for more than 40 years. Considering the present important situations concerning AP, a survey of recent progress in AP is highly desirable. In this review, recent progress in mechanical AP (MAP) and in MAP-related items is presented. MAP is composed of three major components: a BG control algorithm, a drug administration system, and a glucose sensor. Recent progress in development of these components is presented, followed by descriptions of representative MAPs. Although significant progress in the development of MAP has been made, its use in clinical situations is limited or for research purposes at present. The main limiting factor is the slow progress in the development of glucose sensors. However, more widespread clinical application of the MAP will occur in the near future, considering the number of reliable long-life intravenous glucose sensors under development. Another factor is the worldwide recognition of the importance of BG control in acutely ill patients, in whom the period of strict BG control is usually for several days to a few weeks.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19894087     DOI: 10.1007/s10047-009-0463-6

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  95 in total

1.  Design of a mechanical-tunable filter spectrometer for noninvasive glucose measurement.

Authors:  Vidi Saptari; Kamal Youcef-Toumi
Journal:  Appl Opt       Date:  2004-05-01       Impact factor: 1.980

2.  Run-to-run control of meal-related insulin dosing.

Authors:  Howard Zisser; Lois Jovanovic; Frank Doyle; Paulina Ospina; Camelia Owens
Journal:  Diabetes Technol Ther       Date:  2005-02       Impact factor: 6.118

Review 3.  Closing the loop: combining insulin pumps and glucose sensors in children with type 1 diabetes mellitus.

Authors:  Shlomit Shalitin; Moshe Phillip
Journal:  Pediatr Diabetes       Date:  2006-08       Impact factor: 4.866

4.  Efficacy of continuous glucose monitoring system to detect unrecognized hypoglycemia in children and adolescents with type 1 diabetes.

Authors:  Frederico F R Maia; Levimar R Araújo
Journal:  Arq Bras Endocrinol Metabol       Date:  2005-10-19

5.  Feasibility of automating insulin delivery for the treatment of type 1 diabetes.

Authors:  Garry M Steil; Kerstin Rebrin; Christine Darwin; Farzam Hariri; Mohammed F Saad
Journal:  Diabetes       Date:  2006-12       Impact factor: 9.461

6.  Strict glycemic control in diabetic dogs with closed-loop intraperitoneal insulin infusion algorithm designed for an artificial endocrine pancreas.

Authors:  Yasuto Matsuo; Seiya Shimoda; Michiharu Sakakida; Kenro Nishida; Taiji Sekigami; Shinji Ichimori; Kenshi Ichinose; Motoaki Shichiri; Eiichi Araki
Journal:  J Artif Organs       Date:  2003       Impact factor: 1.731

7.  The development of an artificial beta cell system and its validation in depancreatized dogs: the physiological restoration of blood glucose homeostasis.

Authors:  Y Goriya; R Kawamori; M Shichiri; H Abe
Journal:  Med Prog Technol       Date:  1979-06-15

8.  Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008.

Authors:  R Phillip Dellinger; Mitchell M Levy; Jean M Carlet; Julian Bion; Margaret M Parker; Roman Jaeschke; Konrad Reinhart; Derek C Angus; Christian Brun-Buisson; Richard Beale; Thierry Calandra; Jean-Francois Dhainaut; Herwig Gerlach; Maurene Harvey; John J Marini; John Marshall; Marco Ranieri; Graham Ramsay; Jonathan Sevransky; B Taylor Thompson; Sean Townsend; Jeffrey S Vender; Janice L Zimmerman; Jean-Louis Vincent
Journal:  Crit Care Med       Date:  2008-01       Impact factor: 7.598

9.  Standardization of intravenous insulin therapy improves the efficiency and safety of blood glucose control in critically ill adults.

Authors:  Salmaan Kanji; Avinder Singh; Michael Tierney; Hilary Meggison; Lauralyn McIntyre; Paul C Hebert
Journal:  Intensive Care Med       Date:  2004-03-20       Impact factor: 17.440

10.  Association of timing, duration, and intensity of hyperglycemia with intensive care unit mortality in critically ill children.

Authors:  Vijay Srinivasan; Philip C Spinella; Henry R Drott; Carey L Roth; Mark A Helfaer; Vinay Nadkarni
Journal:  Pediatr Crit Care Med       Date:  2004-07       Impact factor: 3.624

View more
  6 in total

Review 1.  Journal of Artificial Organs 2009: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2010-03-24       Impact factor: 1.731

Review 2.  Progressive artificial endocrine pancreas: The era of novel perioperative blood glucose control for surgery.

Authors:  Yuuki Tsukamoto; Takehiro Okabayashi; Kazuhiro Hanazaki
Journal:  Surg Today       Date:  2011-09-16       Impact factor: 2.549

Review 3.  Wearable and implantable pancreas substitutes.

Authors:  Leonardo Ricotti; Tareq Assaf; Paolo Dario; Arianna Menciassi
Journal:  J Artif Organs       Date:  2012-09-20       Impact factor: 1.731

4.  Close relationship between strict blood glucose control, including suppression of blood glucose variability, and mortality reduction in acutely ill patients with glucose intolerance investigated by means of a bedside-type artificial pancreas.

Authors:  Masami Hoshino; Yoshikura Haraguchi; Iwanori Mizushima; Motohiro Sakai
Journal:  J Artif Organs       Date:  2010-07-06       Impact factor: 1.731

5.  Atomic layer deposition-based functionalization of materials for medical and environmental health applications.

Authors:  Roger J Narayan; Shashishekar P Adiga; Michael J Pellin; Larry A Curtiss; Alexander J Hryn; Shane Stafslien; Bret Chisholm; Chun-Che Shih; Chun-Ming Shih; Shing-Jong Lin; Yea-Yang Su; Chunming Jin; Junping Zhang; Nancy A Monteiro-Riviere; Jeffrey W Elam
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2010-04-28       Impact factor: 4.226

6.  Effects of electrical microstimulation of peripheral sympathetic nervous fascicle on glucose uptake in rats.

Authors:  Daisuke Sato; Go Shinzawa; Masataka Kusunoki; Tomonao Matsui; Hiroyuki Sasaki; Zhonggang Feng; Atsuyoshi Nishina; Takao Nakamura
Journal:  J Artif Organs       Date:  2013-03-07       Impact factor: 1.731

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.