Literature DB >> 16797425

Peripheral venous pressure as a predictor of central venous pressure during orthotopic liver transplantation.

Nir Hoftman1, Michelle Braunfeld, Gil Hoftman, Aman Mahajan.   

Abstract

STUDY
OBJECTIVE: To assess the reliability of peripheral venous pressure (PVP) as a predictor of central venous pressure (CVP) in the setting of rapidly fluctuating hemodynamics during orthotopic liver transplant surgery.
DESIGN: Prospective clinical trial.
SETTING: UCLA Medical Center, main operating room-liver transplant surgery. PATIENTS: Nine adult patients with liver failure undergoing orthotopic liver transplant surgery.
INTERVENTIONS: A pulmonary artery catheter and a 20-g antecubital peripheral intravenous catheter dedicated to measuring PVP were placed in all patients after standard general endotracheal anesthesia induction and institution of mechanical ventilation. MEASUREMENTS: Peripheral venous pressure and CVP were recorded every 5 minutes and/or during predetermined, well-defined surgical events (skin incision, venovenous bypass initiation, portal vein anastamosis, 5 minute post graft reperfusion, abdominal closure). Pulmonary artery pressure and cardiac output (via thermodilution) were recorded every 15 and 30 minutes, respectively. MAIN
RESULTS: Peripheral venous pressure (mean +/- SD) was 11.0 +/- 4.5 mmHg vs a CVP of 9.5 +/- 5.0; the two measurements differed by an average of 1.5 +/- 1.6 mmHg. Peripheral venous pressure correlated highly with CVP in every patient, and the overall correlation among all nine patients calculated using a random-effects regression model was r = 0.95 (P < 0.0001). A Bland-Altman analysis used to determine the accuracy of PVP in comparison to CVP yielded a bias of -1.5 mmHg and a precision of +/-3.1 mm Hg.
CONCLUSION: Our study confirms that PVP correlates with CVP even under adverse hemodynamic conditions in patients undergoing liver transplantation.

Entities:  

Mesh:

Year:  2006        PMID: 16797425     DOI: 10.1016/j.jclinane.2005.09.031

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  6 in total

1.  Influence of tissue pressure on central venous pressure/peripheral venous pressure correlation: An experimental report.

Authors:  Martyn G Harvey; Grant Cave
Journal:  World J Emerg Med       Date:  2011

2.  Analysis of central venous pressure (CVP) signals using mathematical methods.

Authors:  Parham Atefvahid; Kamran Hassani; Kamal Jafarian; D John Doyle; Hessam Ahmadi
Journal:  J Clin Monit Comput       Date:  2016-05-03       Impact factor: 2.502

3.  Comparative utility of centrally versus peripherally transduced venous pressure monitoring in the perioperative period in spine surgery patients.

Authors:  Anna Maria Bombardieri; James Beckman; Pamela Shaw; Federico P Girardi; Yan Ma; Stavros G Memtsoudis
Journal:  J Clin Anesth       Date:  2012-09-20       Impact factor: 9.452

4.  Comparison of the central venous pressure from internal jugular vein and the pressure measured from the peripherally inserted antecubital central catheter (PICCP) in liver transplantation recipients.

Authors:  Jung-Yeon Yun; So-Hee Park; Dae-Soon Cho; Hae-Jeung Jeung; Soon-Ae Lee; So Jin Seo
Journal:  Korean J Anesthesiol       Date:  2011-10-22

5.  Peripheral venous pressure as a reliable predictor for monitoring central venous pressure in patients with burns.

Authors:  Lulu Sherif; Vikas S Joshi; Anjali Ollapally; Prithi Jain; Kishan Shetty; Karl Sa Ribeiro
Journal:  Indian J Crit Care Med       Date:  2015-04

6.  Correlation between central venous pressure and peripheral venous pressure with passive leg raise in patients on mechanical ventilation.

Authors:  Dharmendra Kumar; Syed Moied Ahmed; Shahna Ali; Utpal Ray; Ankur Varshney; Kashmiri Doley
Journal:  Indian J Crit Care Med       Date:  2015-11
  6 in total