Literature DB >> 16796287

Measurement of volume changes after sinus floor augmentation with a phycogenic hydroxyapatite.

Felix Wanschitz1, Michael Figl, Arne Wagner, Ewers Rolf.   

Abstract

PURPOSE: The purpose of this study was the determination of time-dependent volumetric changes of particulate sinus inlay grafts. A mixture of phycogenic hydroxyapatite (Algipore/C-Graft) and autologous bone collected from the surgical access area was used as the grafting material.
MATERIALS AND METHODS: Thirty-three sinus floor augmentations using phycogenic hydroxyapatite combined with autologous bone collected at the augmentation site and venous blood were performed on 18 patients aged 57.4 +/- 12.5 years (mean +/- SD) with severe atrophy of the posterior maxilla. Graft volume was measured 1 to 14 days postoperatively and before the placement of dental implants 6.1 +/- 2.1 months later (mean +/- SD; range, 4 to 11 months) to evaluate the amount of time-dependent resorption of the implanted material on computerized tomographic (CT) images of the augmented region. The images were put into Digital Imaging and Communications in Medicine (DICOM) format and evaluated using the software library Analyze. The implanted bone replacement material was plotted manually on each CT slice, and the volume of the implanted material was calculated.
RESULTS: The average volume loss of the bone replacement material during the observation period was 13.9% +/- 1.9% (mean +/- SEM). All sinus floor augmentations healed without complications except for delayed membrane exposure in 2 cases. DISCUSSION: The results indicate that the graft material, a mixture of Algipore, bone chips from the access area, and venous blood, exhibited a small volume loss over a period of approximately 6 months, thus providing predictable height for second-stage implant surgery.
CONCLUSION: Further investigations are needed to evaluate long-term stability and implant success.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16796287

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  11 in total

1.  The influence of bone substitute materials on the bone volume after maxillary sinus augmentation: a microcomputerized tomography study.

Authors:  Sebastian Kühl; Christoph Brochhausen; Hermann Götz; Andreas Filippi; Michael Payer; Bernd d'Hoedt; Matthias Kreisler
Journal:  Clin Oral Investig       Date:  2012-04-27       Impact factor: 3.573

Review 2.  When 1+1>2: Nanostructured composites for hard tissue engineering applications.

Authors:  Vuk Uskoković
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2015-08-01       Impact factor: 7.328

3.  Radiographic Analysis of Graft Dimensional Changes in Transcrestal Maxillary Sinus Augmentation: A Retrospective Study.

Authors:  Luca Comuzzi; Margherita Tumedei; Adriano Piattelli; Gianluca Tartaglia; Massimo Del Fabbro
Journal:  Materials (Basel)       Date:  2022-04-19       Impact factor: 3.748

4.  Evaluation of volume changes following lateral window maxillary sinus floor elevation using Minics software.

Authors:  Hanfei Zhang; Huiting Hu; Cong Li; Yingxin Ye; Mingdeng Rong; Yong Yang
Journal:  Ann Transl Med       Date:  2022-09

5.  A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials.

Authors:  Pham-Duong Hieu; Jin-Hyung Chung; Sung-Bin Yim; Ki-Seok Hong
Journal:  J Periodontal Implant Sci       Date:  2010-02-28       Impact factor: 2.614

6.  Evaluation of Three-Dimensional Volumetric Changes After Sinus Floor Augmentation with Mineralized Cortical Bone Allograft.

Authors:  Antoine Berberi; Lea Bouserhal; Nabih Nader; Rita Bou Assaf; Nayla Bassil Nassif; Joseph Bouserhal; Ziad Salameh
Journal:  J Maxillofac Oral Surg       Date:  2014-12-24

7.  The Efficacy of the Graft Materials after Sinus Elevation: Retrospective Comparative Study Using Panoramic Radiography.

Authors:  Tae Min Jeong; Jeong Keun Lee
Journal:  Maxillofac Plast Reconstr Surg       Date:  2014-07-30

8.  The Effect of Alendronate on Various Graft Materials Used in Maxillary Sinus Augmentation: A Rabbit Study.

Authors:  Ferhat Ayranci; Metin Gungormus; Mehmet Melih Omezli; Betul Gundogdu
Journal:  Iran Red Crescent Med J       Date:  2015-12-27       Impact factor: 0.611

9.  A radiographic evaluation of graft height changes after maxillary sinus augmentation.

Authors:  Do-Hyung Kim; Min-Jeong Ko; Jae-Hong Lee; Seoung-Nyum Jeong
Journal:  J Periodontal Implant Sci       Date:  2018-06-28       Impact factor: 2.614

10.  Late-term healing in an augmented sinus with different ratios of biphasic calcium phosphate: a pilot study using a rabbit sinus model.

Authors:  Hyun-Chang Lim; Ji-Youn Hong; Jung-Seok Lee; Ui-Won Jung; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2016-02-22       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.