Literature DB >> 36267755

Evaluation of volume changes following lateral window maxillary sinus floor elevation using Minics software.

Hanfei Zhang1, Huiting Hu1, Cong Li2, Yingxin Ye3, Mingdeng Rong1, Yong Yang1.   

Abstract

Background: Significant volume changes at the site of lateral window maxillary sinus floor elevation have been reported 6 months postoperatively, with stabilization thereafter. However, at present, there is no consensus regarding the gold standard to assess the shape and volume of the bone graft site after implantation. This study aimed to analyze volume changes in the lateral window maxillary sinus floor elevation region using Minics software.
Methods: We analyzed 40 patients who underwent lateral window maxillary sinus floor elevation surgery at the Stomatology Department of Binhaiwan Central Hospital, Dongguan, China between 2017 and 2020. Twenty patients underwent lateral window maxillary sinus floor elevation with simultaneous implantation, while 20 patients underwent lateral window maxillary sinus floor elevation with delayed implantation 6 months later. Minics software was used for three-dimensional analysis of the elevation site on the day after surgery (T1) and 6 months after surgery (T2) in both groups.
Results: The elevation site volume was reduced 6 months after lateral window maxillary sinus floor elevation. The differences in the length, width, height from the tip, and volume of the implant between T1 and T2 were statistically significant. Conclusions: The length, width, height, and volume of the lateral window maxillary sinus floor elevation region were reduced using Minics software, suggesting that the volume of the elevation site should be enlarged as much as possible during the operation to prevent volume shrinkage. 2022 Annals of Translational Medicine. All rights reserved.

Entities:  

Keywords:  Bone graft; lateral window maxillary sinus floor elevation; maxillary sinus; software; three-dimensional volume analysis software

Year:  2022        PMID: 36267755      PMCID: PMC9577812          DOI: 10.21037/atm-22-3110

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


  25 in total

Review 1.  The influence of remaining alveolar bone upon lateral window sinus augmentation implant survival.

Authors:  Hector F Rios; Gustavo Avila; Pablo Galindo; Emanuel Bratu; Hom-Lay Wang
Journal:  Implant Dent       Date:  2009-10       Impact factor: 2.454

2.  Measurement of volume changes after sinus floor augmentation with a phycogenic hydroxyapatite.

Authors:  Felix Wanschitz; Michael Figl; Arne Wagner; Ewers Rolf
Journal:  Int J Oral Maxillofac Implants       Date:  2006 May-Jun       Impact factor: 2.804

3.  Evaluation of three-dimensional changes after sinus floor augmentation with different grafting materials.

Authors:  Robert Kirmeier; Michael Payer; Martin Wehrschuetz; Norbert Jakse; Susanne Platzer; Martin Lorenzoni
Journal:  Clin Oral Implants Res       Date:  2008-04       Impact factor: 5.977

4.  Sinus floor augmentation with simultaneous implant placement in the severely atrophic maxilla.

Authors:  M Peleg; Z Mazor; G Chaushu; A K Garg
Journal:  J Periodontol       Date:  1998-12       Impact factor: 6.993

5.  Reliability of upper airway linear, area, and volumetric measurements in cone-beam computed tomography.

Authors:  Claudia Trindade Mattos; Christiane Vasconcellos Cruz; Thais Cristina Sobreira da Matta; Leonardo de Abreu Pereira; Priscilla de Almeida Solon-de-Mello; Antônio Carlos de Oliveira Ruellas; Eduardo Franzotti Sant'anna
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-02       Impact factor: 2.650

6.  Three-dimensional volumetric changes of 5 different bone grafts in human maxillary sinuses reconstruction: a randomized clinical study.

Authors:  Juliana Dreyer Menezes; Rodrigo Dos Santos Pereira; Anderson Maikon de Souza Santos; Natália Barbosa de Siqueira; Fernanda Brasil Daura Jorge Boos-Lima; Eduardo Hochuli-Vieira
Journal:  Oral Maxillofac Surg       Date:  2021-03-13

7.  A 10-year longitudinal study of 160 implants simultaneously installed in severely atrophic posterior maxillas grafted with autogenous bone and a synthetic bioactive resorbable graft.

Authors:  Marcelo C Manso; Thomas Wassal
Journal:  Implant Dent       Date:  2010-08       Impact factor: 2.454

8.  Radiographic Analysis of Graft Dimensional Changes in Transcrestal Maxillary Sinus Augmentation: A Retrospective Study.

Authors:  Luca Comuzzi; Margherita Tumedei; Adriano Piattelli; Gianluca Tartaglia; Massimo Del Fabbro
Journal:  Materials (Basel)       Date:  2022-04-19       Impact factor: 3.748

Review 9.  Volume changes of maxillary sinus augmentations over time: a systematic review.

Authors:  Siddharth Shanbhag; Vivek Shanbhag; Andreas Stavropoulos
Journal:  Int J Oral Maxillofac Implants       Date:  2014 Jul-Aug       Impact factor: 2.804

Review 10.  Non-grafted versus grafted sinus lift procedures for implantation in the atrophic maxilla: a systematic review and meta-analysis of randomized controlled trials.

Authors:  S A N Lie; R M M A Claessen; C A W Leung; H-A Merten; P A W H Kessler
Journal:  Int J Oral Maxillofac Surg       Date:  2021-04-10       Impact factor: 2.789

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.