Antoine Berberi1, Lea Bouserhal2, Nabih Nader3, Rita Bou Assaf3, Nayla Bassil Nassif4, Joseph Bouserhal4, Ziad Salameh3. 1. Oral and Maxillofacial Surgery Department, School of Dentistry, Lebanese University, P.O. Box 5208-116, Beirut, Lebanon ; Oral Surgery Section, ENT Department, Sacre-Coeur Hospital, Lebanese University, Beirut, Lebanon. 2. Department of Orthodontics, Case Western Reserve University, Cleveland, OH USA. 3. Oral and Maxillofacial Surgery Department, School of Dentistry, Lebanese University, P.O. Box 5208-116, Beirut, Lebanon. 4. Orthodontics Department, Faculty of Dental Medicine, Saint-Joseph University, Beirut, Lebanon.
Abstract
AIM: The aim of this retrospective study was to quantify three-dimensional (3D) volumetric bone changes over a two-year period in maxillary sinuses augmented with a mineralized cortical bone allograft material (MCBA) material. PATIENTS AND METHODS: Eleven patients (6 males and 5 females) with mean of age of 51.6 (range: 46-61) years were treated to increase the vertical dimension of the alveolar crest by maxillary sinus floor augmentation procedure. Study data were collected from patient records and by analyzing preoperative radiographs and cone beam computed tomography (CBCT) scans taken within the first two weeks after maxillary sinus lift (T0), immediately before implant placement four months after grafting (T1), and after one year of implant loading (T2). All DICOM-formatted images were rendered into volumetric images using software that automatically calculated the volume of the grafted material in cubic centimeters. RESULTS: Mean graft volume was 16.24 ± 1.54 cm(3) at T0, 14.48 ± 1.48 cm(3) at T1 and 13.06 ± 1.39 cm(3) at T2. Mean volume retraction resulted in 1.76 ± 0.34 cm(3) ΔV1 (T0-T1) and 1.42 ± 0.4 cm(3) ΔV2 (T1-T2) and was 10.83 % of the initial total volume at (T0-T1) and 9.8 % of the total volume (T1-T2). CONCLUSION: The present retrospective investigation demonstrated a 20.63 % decrease in graft volume. Volumetric 3D assessment of CBCT scans with the selected software appeared to be a promising approach to quantifying long-term changes in the grafted area.
AIM: The aim of this retrospective study was to quantify three-dimensional (3D) volumetric bone changes over a two-year period in maxillary sinuses augmented with a mineralized cortical bone allograft material (MCBA) material. PATIENTS AND METHODS: Eleven patients (6 males and 5 females) with mean of age of 51.6 (range: 46-61) years were treated to increase the vertical dimension of the alveolar crest by maxillary sinus floor augmentation procedure. Study data were collected from patient records and by analyzing preoperative radiographs and cone beam computed tomography (CBCT) scans taken within the first two weeks after maxillary sinus lift (T0), immediately before implant placement four months after grafting (T1), and after one year of implant loading (T2). All DICOM-formatted images were rendered into volumetric images using software that automatically calculated the volume of the grafted material in cubic centimeters. RESULTS: Mean graft volume was 16.24 ± 1.54 cm(3) at T0, 14.48 ± 1.48 cm(3) at T1 and 13.06 ± 1.39 cm(3) at T2. Mean volume retraction resulted in 1.76 ± 0.34 cm(3) ΔV1 (T0-T1) and 1.42 ± 0.4 cm(3) ΔV2 (T1-T2) and was 10.83 % of the initial total volume at (T0-T1) and 9.8 % of the total volume (T1-T2). CONCLUSION: The present retrospective investigation demonstrated a 20.63 % decrease in graft volume. Volumetric 3D assessment of CBCT scans with the selected software appeared to be a promising approach to quantifying long-term changes in the grafted area.
Authors: Robert Kirmeier; Michael Payer; Martin Wehrschuetz; Norbert Jakse; Susanne Platzer; Martin Lorenzoni Journal: Clin Oral Implants Res Date: 2008-04 Impact factor: 5.977