Literature DB >> 16790908

Fifty years of Monte Carlo simulations for medical physics.

D W O Rogers1.   

Abstract

Monte Carlo techniques have become ubiquitous in medical physics over the last 50 years with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 and 2000 when the numbers levelled off. While recognizing the many other roles that Monte Carlo techniques have played in medical physics, this review emphasizes techniques for electron-photon transport simulations. The broad range of codes available is mentioned but there is special emphasis on the EGS4/EGSnrc code system which the author has helped develop for 25 years. The importance of the 1987 Erice Summer School on Monte Carlo techniques is highlighted. As an illustrative example of the role Monte Carlo techniques have played, the history of the correction for wall attenuation and scatter in an ion chamber is presented as it demonstrates the interplay between a specific problem and the development of tools to solve the problem which in turn leads to applications in other areas.

Mesh:

Year:  2006        PMID: 16790908     DOI: 10.1088/0031-9155/51/13/R17

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  40 in total

Review 1.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

2.  Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

Authors:  Kyle McMillan; Michael McNitt-Gray; Dan Ruan
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

3.  The effect of energy spectrum change on DNA damage in and out of field in 10-MV clinical photon beams.

Authors:  A O Ezzati; Y Xiao; M Sohrabpour; M T Studenski
Journal:  Med Biol Eng Comput       Date:  2014-10-29       Impact factor: 2.602

Review 4.  Monte Carlo systems used for treatment planning and dose verification.

Authors:  Lorenzo Brualla; Miguel Rodriguez; Antonio M Lallena
Journal:  Strahlenther Onkol       Date:  2016-11-25       Impact factor: 3.621

5.  Conversion coefficients for determining organ doses in paediatric spine radiography.

Authors:  Michael Seidenbusch; Karl Schneider
Journal:  Pediatr Radiol       Date:  2014-02-09

Review 6.  Air kerma and absorbed dose standards for reference dosimetry in brachytherapy.

Authors:  T Sander
Journal:  Br J Radiol       Date:  2014-07-07       Impact factor: 3.039

Review 7.  Monte Carlo Simulations of Particle Interactions with Tissue in Carbon Ion Therapy.

Authors:  George Dedes; Katia Parodi
Journal:  Int J Part Ther       Date:  2016-02-09

Review 8.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

9.  A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model.

Authors:  Yuhe Wang; Thomas R Mazur; Olga Green; Yanle Hu; Hua Li; Vivian Rodriguez; H Omar Wooten; Deshan Yang; Tianyu Zhao; Sasa Mutic; H Harold Li
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

10.  Patient radiation exposure in a modern, large-volume, pediatric cardiac catheterization laboratory.

Authors:  Andrew C Glatz; Akash Patel; Xiaowei Zhu; Yoav Dori; Brian D Hanna; Matthew J Gillespie; Jonathan J Rome
Journal:  Pediatr Cardiol       Date:  2014-01-18       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.