Literature DB >> 16776358

Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography reconstruction measurements.

Masaaki Chazono1, Shigeru Soshi, Takeshi Inoue, Yoshikuni Kida, Chikara Ushiku.   

Abstract

OBJECT: The purpose of this study was to evaluate the linear and angular parameters of the vertebral body (VB) required for cervical pedicle screw (CPS) insertion by using multiplanar computerized tomography (CT) reconstructions.
METHODS: Three hundred fifteen vertebrae from C-3 to C-7 in 63 patients were studied. Pedicle dimensions such as pedicle transverse angle (PTA), pedicle sagittal angle (PSA), and pedicle outer width (POW) were measured on axial CT reconstructions, as were linear parameters including the lateral mass thickness (LMT), the anteroposterior (AP) and mediolateral distances between spinal canal and transverse foramen, and spinal canal longitudinal and transverse diameter. In addition, the correlations between PTA and other parameters were calculated using univariate linear regression analysis. The overall mean LMT ranged from 10.7 to 12.6 mm. The smallest mean AP spinal canal-transverse foramen distance was found at C-7 (1.1 mm),whereas the largest mean distance was at C-4 (3.1 mm). The smallest mean mediolateral spinal canal-transverse foramen distance was found at C-4 (1.2 mm), whereas the largest mean distance was at C-7 (4.7 mm). There were significant intergroup differences between male and female patients except for PTA and spinal canal longitudinal diameter. The PTA had a direct linear correlation with AP and mediolateral spinal canal-transverse foramen distances. The largest Pearson coefficient was 0.71 between the PTA and AP spinal canal-transverse foramen distance and the inverse one was -0.73 between the PTA and mediolateral spinal canal-transverse foramen distance.
CONCLUSIONS: Analysis of the data obtained in this study suggests that not only pedicle dimensions but also linear and angular parameters of the VB can be useful data when inserting a CPS.

Entities:  

Mesh:

Year:  2006        PMID: 16776358     DOI: 10.3171/spi.2006.4.6.472

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  21 in total

Review 1.  Ethnic differences in pedicle and bony spinal canal dimensions calculated from computed tomography of the cervical spine: a review of the English-language literature.

Authors:  Masaaki Chazono; Takaaki Tanaka; Yoshio Kumagae; Tomoaki Sai; Keishi Marumo
Journal:  Eur Spine J       Date:  2012-04-19       Impact factor: 3.134

2.  CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement.

Authors:  Zhu Ruofu; Yang Huilin; Hu Xiaoyun; He Xishun; Tang Tiansi; Chen Liang; Li Xigong
Journal:  Surg Radiol Anat       Date:  2008-03-20       Impact factor: 1.246

3.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

4.  An analysis of the anatomic features of the cervical spine using computed tomography to select safer screw insertion techniques.

Authors:  Masahiro Nishinome; Haku Iizuka; Yoichi Iizuka; Kenji Takagishi
Journal:  Eur Spine J       Date:  2013-07-06       Impact factor: 3.134

5.  Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve.

Authors:  Hisashi Yoshimoto; Shigenobu Sato; Takahiko Hyakumachi; Yasushi Yanagibashi; Taiki Kanno; Takeshi Masuda
Journal:  Eur Spine J       Date:  2009-08-04       Impact factor: 3.134

6.  Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae.

Authors:  Dong-Ho Lee; Sung-Woo Lee; Suk Jung Kang; Chang Ju Hwang; Nam Heun Kim; Ju-Yul Bae; Yung-Tae Kim; Choon Sung Lee; K Daniel Riew
Journal:  Eur Spine J       Date:  2011-04-09       Impact factor: 3.134

7.  Computed tomographic morphometric analysis of cervical pedicles in a multi-ethnic Asian population and relevance to subaxial cervical pedicle screw fixation.

Authors:  Thangaraj Munusamy; Ady Thien; Mark Gerad Anthony; Ramesh Bakthavachalam; Shree Kumar Dinesh
Journal:  Eur Spine J       Date:  2014-08-26       Impact factor: 3.134

8.  Screw perforation features in 129 consecutive patients performed computer-guided cervical pedicle screw insertion.

Authors:  Masashi Uehara; Jun Takahashi; Shota Ikegami; Keijiro Mukaiyama; Shugo Kuraishi; Masayuki Shimizu; Toshimasa Futatsugi; Nobuhide Ogihara; Hiroyuki Hashidate; Hiroki Hirabayashi; Hiroyuki Kato
Journal:  Eur Spine J       Date:  2014-08-06       Impact factor: 3.134

9.  Cervical pedicle screw placement using intraoperative computed tomography imaging with a mobile scanner gantry.

Authors:  Toshitaka Yoshii; Takashi Hirai; Kenichiro Sakai; Hiroyuki Inose; Tsuyoshi Kato; Atsushi Okawa
Journal:  Eur Spine J       Date:  2016-03-16       Impact factor: 3.134

10.  Computerized Tomography-Based Morphometric Analysis of Subaxial Cervical Spine Pedicle in Asymptomatic Indian Population.

Authors:  Kamran Farooque; Rahul Yadav; Buddhadev Chowdhury; Shivanand Gamanagatti; Atin Kumar; Pradeep Kumar Meena
Journal:  Int J Spine Surg       Date:  2018-08-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.