Literature DB >> 16714640

Abdominal MRI at 3.0 T: the basics revisited.

Elmar M Merkle1, Brian M Dale.   

Abstract

OBJECTIVE: The purpose of our article is to describe the underlying physics concepts of abdominal MRI at 3.0 T and their impact on signal-to-noise ratio, susceptibility artifacts, chemical shift artifacts, and dielectric effects.
CONCLUSION: Abdominal MR sequence protocols optimized for 1.5-T scanners should not be transferred to 3.0 T without substantial modification. In addition, specific patient groups--for example, large patients with ascites--are not well suited to undergo an abdominal MRI study at 3.0 T.

Entities:  

Mesh:

Year:  2006        PMID: 16714640     DOI: 10.2214/AJR.05.0932

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  35 in total

Review 1.  [MR colography: technique, indications, and findings].

Authors:  T C Lauenstein; S Kinner; S C Ladd
Journal:  Radiologe       Date:  2008-02       Impact factor: 0.635

2.  Newly developed surface coil for endoluminal MRI, depiction of pig gastric wall layers and vascular architecture in ex vivo study.

Authors:  Yoshinori Morita; Hiromu Kutsumi; Hayato Yoshinaka; Yuichiro Matsuoka; Kagayaki Kuroda; Masakazu Gotanda; Naomi Sekino; Etsuko Kumamoto; Masaru Yoshida; Hideto Inokuchi; Takeshi Azuma
Journal:  J Gastroenterol       Date:  2009-03-17       Impact factor: 7.527

3.  Body MRI artefacts: from image degradation to diagnostic utility.

Authors:  G Rescinito; C Sirlin; G Cittadini
Journal:  Radiol Med       Date:  2008-10-04       Impact factor: 3.469

Review 4.  [New developments in MRI of the liver].

Authors:  N Bastati-Huber; H Prosch; S Baroud; S Magnaldi; W Schima; A Ba-Ssalamah
Journal:  Radiologe       Date:  2011-08       Impact factor: 0.635

Review 5.  Body MR Imaging: Artifacts, k-Space, and Solutions.

Authors:  Susie Y Huang; Ravi T Seethamraju; Pritesh Patel; Peter F Hahn; John E Kirsch; Alexander R Guimaraes
Journal:  Radiographics       Date:  2015-07-24       Impact factor: 5.333

Review 6.  MRI evaluation and safety in the developing brain.

Authors:  Shannon Tocchio; Beth Kline-Fath; Emanuel Kanal; Vincent J Schmithorst; Ashok Panigrahy
Journal:  Semin Perinatol       Date:  2015-03-03       Impact factor: 3.300

Review 7.  Image-quality optimization and artifact reduction in fetal magnetic resonance imaging.

Authors:  Fedel Machado-Rivas; Camilo Jaimes; John E Kirsch; Michael S Gee
Journal:  Pediatr Radiol       Date:  2020-11-30

8.  Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains.

Authors:  Dan Zhu; Wenbo Li; Dapeng Liu; Guanshu Liu; Yigang Pei; Taehoon Shin; Farzad Sedaghat; Qin Qin
Journal:  Magn Reson Med       Date:  2020-02-04       Impact factor: 4.668

9.  Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.

Authors:  Mathilde Wagner; Léon Maggiori; Maxime Ronot; Valérie Paradis; Valérie Vilgrain; Yves Panis; Bernard E Van Beers
Journal:  Eur Radiol       Date:  2013-03-02       Impact factor: 5.315

10.  Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T.

Authors:  Benjamin E Northrup; Kyle S McCommis; Haosen Zhang; Shuddhadeb Ray; Pamela K Woodard; Robert J Gropler; Jie Zheng
Journal:  J Cardiovasc Magn Reson       Date:  2008-11-17       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.