Influence of different storage methods on laser fluorescence values: a two-year study.

P Francescut1, B Zimmerli, A Lussi.   

Abstract

The aim of this study was to assess the influence on the infrared laser fluorescence response of some storage methods commonly used in dental research. Forty extracted permanent teeth, selected from a pool of frozen teeth, were divided into four groups of 10. Three groups were stored at 4 degrees C in 1% chloramine, 10% formalin or 0.02% thymol solution. The fourth group was stored at -20 degrees C (no storage solution added). Fluorescence measurements were performed at 14, 77, 113, 168, 232, 486 and 737 days. After 2 years, significant decreases in fluorescence (p<0.01) for the samples in formalin (-60%), chloramine (-72%) and thymol (-54%) were observed. The frozen teeth showed a slight but non-significant increase in fluorescence of 5% (p>0.01). Storing solutions have a significant influence on the fluorescence yield. Samples used for in vitro purposes stored frozen do not significantly change their fluorescence response. Thus, cut-off values obtained under the latter conditions could be extrapolated to the in vivo situation. Copyright (c) 2006 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16707864     DOI: 10.1159/000092223

Source DB:  PubMed          Journal:  Caries Res        ISSN: 0008-6568            Impact factor:   4.056


  27 in total

1.  Performance of a new fluorescence camera for detection of occlusal caries in vitro.

Authors:  Anahita Jablonski-Momeni; Fabian Liebegall; Richard Stoll; Monika Heinzel-Gutenbrunner; Klaus Pieper
Journal:  Lasers Med Sci       Date:  2012-03-21       Impact factor: 3.161

2.  Performance of laser fluorescence devices, visual and radiographic examination for the detection of occlusal caries in primary molars.

Authors:  Klaus W Neuhaus; Jonas Almeida Rodrigues; Isabel Hug; Herman Stich; Adrian Lussi
Journal:  Clin Oral Investig       Date:  2010-05-27       Impact factor: 3.573

3.  The influence of zero value subtraction on the performance of a new laser fluorescence device for approximal caries detection.

Authors:  Jonas Almeida Rodrigues; Jonas de Almeida Rodrigues; Isabel Hug; Adrian Lussi
Journal:  Lasers Med Sci       Date:  2008-02-29       Impact factor: 3.161

4.  Relationship between DIAGNOdent values and sealant penetration depth on occlusal fissures.

Authors:  Jonas A Rodrigues; Michele B Diniz; Isabel Hug; Rita C L Cordeiro; Adrian Lussi
Journal:  Clin Oral Investig       Date:  2009-08-05       Impact factor: 3.573

5.  Caries detection under composite restorations by laser fluorescence and digital radiography.

Authors:  Suwadee Kositbowornchai; Chotikpanich Sukanya; Tangkittikasem Tidarat; Thongsombat Chanoggarn
Journal:  Clin Oral Investig       Date:  2012-12-16       Impact factor: 3.573

6.  Analysis of the effects of air polishing powders containing sodium bicarbonate and glycine on human teeth.

Authors:  Julia Bühler; Fredy Schmidli; Roland Weiger; Clemens Walter
Journal:  Clin Oral Investig       Date:  2014-09-21       Impact factor: 3.573

7.  Diagnostic performance of a new red light LED device for approximal caries detection.

Authors:  Klaus W Neuhaus; Philip Ciucchi; Jonas Almeida Rodrigues; Isabelle Hug; Marta Emerich; Adrian Lussi
Journal:  Lasers Med Sci       Date:  2014-06-07       Impact factor: 3.161

8.  Diagnostic validity of the use of ICDAS II and DIAGNOdent pen verified by micro-computed tomography for the detection of occlusal caries lesions-an in vitro evaluation.

Authors:  Elzbieta Luczaj-Cepowicz; Grazyna Marczuk-Kolada; Marta Obidzinska; Jarosław Sidun
Journal:  Lasers Med Sci       Date:  2019-06-14       Impact factor: 3.161

9.  An in vitro comparison of different diagnostic methods in detection of residual dentinal caries.

Authors:  Nimet Unlu; Rabia Banu Ermis; Sevgi Sener; Ebru Kucukyilmaz; Ali Riza Cetin
Journal:  Int J Dent       Date:  2010-06-03

10.  Caries diagnosis using light fluorescence devices in comparison with traditional visual and tactile evaluation: a prospective study in 152 patients.

Authors:  María Melo; Agustín Pascual; Isabel Camps; Ángel Del Campo; Javier Ata-Ali
Journal:  Odontology       Date:  2016-09-21       Impact factor: 2.634

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.