Literature DB >> 16642854

Effects of introducing unprocessed low-frequency information on the reception of envelope-vocoder processed speech.

Michael K Qin1, Andrew J Oxenham.   

Abstract

This study investigated the benefits of adding unprocessed low-frequency information to acoustic simulations of cochlear-implant processing in normal-hearing listeners. Implant processing was simulated using an eight-channel noise-excited envelope vocoder, and low-frequency information was added by replacing the lower frequency channels of the processor with a low-pass-filtered version of the original stimulus. Experiment 1 measured sentence-level speech reception as a function of target-to-masker ratio, with either steady-state speech-shaped noise or single-talker maskers. Experiment 2 measured listeners' ability to identify two vowels presented simultaneously, as a function of the F0 difference between the two vowels. In both experiments low-frequency information was added below either 300 or 600 Hz. The introduction of the additional low-frequency information led to substantial and significant improvements in performance in both experiments, with a greater improvement observed for the higher (600 Hz) than for the lower (300 Hz) cutoff frequency. However, performance never equaled performance in the unprocessed conditions. The results confirm other recent demonstrations that added low-frequency information can provide significant benefits in intelligibility, which may at least in part be attributed to improvements in F0 representation. The findings provide further support for efforts to make use of residual acoustic hearing in cochlear-implant users.

Mesh:

Year:  2006        PMID: 16642854     DOI: 10.1121/1.2178719

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  67 in total

1.  Relative contribution of target and masker temporal fine structure to the unmasking of consonants in noise.

Authors:  Frédéric Apoux; Eric W Healy
Journal:  J Acoust Soc Am       Date:  2011-12       Impact factor: 1.840

2.  The relative phonetic contributions of a cochlear implant and residual acoustic hearing to bimodal speech perception.

Authors:  Benjamin M Sheffield; Fan-Gang Zeng
Journal:  J Acoust Soc Am       Date:  2012-01       Impact factor: 1.840

3.  Cochlear implants: the hazards of unexpected success.

Authors:  Jay T Rubinstein
Journal:  CMAJ       Date:  2012-02-21       Impact factor: 8.262

4.  Fundamental frequency is critical to speech perception in noise in combined acoustic and electric hearing.

Authors:  Jeff Carroll; Stephanie Tiaden; Fan-Gang Zeng
Journal:  J Acoust Soc Am       Date:  2011-10       Impact factor: 1.840

5.  Effects of introducing low-frequency harmonics in the perception of vocoded telephone speech.

Authors:  Yi Hu; Philipos C Loizou
Journal:  J Acoust Soc Am       Date:  2010-09       Impact factor: 1.840

6.  Shifting fundamental frequency in simulated electric-acoustic listening.

Authors:  Christopher A Brown; Nicole M Scherrer; Sid P Bacon
Journal:  J Acoust Soc Am       Date:  2010-09       Impact factor: 1.840

7.  Relative contribution of off- and on-frequency spectral components of background noise to the masking of unprocessed and vocoded speech.

Authors:  Frédéric Apoux; Eric W Healy
Journal:  J Acoust Soc Am       Date:  2010-10       Impact factor: 1.840

8.  A simulation study of harmonics regeneration in noise reduction for electric and acoustic stimulation.

Authors:  Yi Hu
Journal:  J Acoust Soc Am       Date:  2010-05       Impact factor: 1.840

9.  Masking release for low- and high-pass-filtered speech in the presence of noise and single-talker interference.

Authors:  Andrew J Oxenham; Andrea M Simonson
Journal:  J Acoust Soc Am       Date:  2009-01       Impact factor: 1.840

10.  Comparison of two cochlear implant coding strategies on speech perception.

Authors:  Margaret T Dillon; Emily Buss; English R King; Ellen J Deres; Sarah N Obarowski; Meredith L Anderson; Marcia C Adunka
Journal:  Cochlear Implants Int       Date:  2016-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.