106Ru/106Rh plaque and proton radiotherapy for ocular melanoma: a comparative dosimetric study.

F Mourtada1, N Koch, W Newhauser.   

Abstract

The objective of this study was to perform comparative dosimetric studies of both 106Ru/106Rh plaque brachytherapy and external beam proton therapy proposed for ocular treatments at the University of Texas M. D. Anderson Cancer Center, Houston, TX, USA. These modalities were also compared with traditional 125I plaque brachytherapy. Using a standardised eye model with a representative ocular melanoma tumour, the relative dose distributions within the tumour and surrounding tissue were calculated using the Monte Carlo code MCNPX. Published absorbed dose distributions benchmarked the Monte Carlo models. Results indicate that the proton beam provided superior dose uniformity within the tumour volume, whereas the dose distribution from 106Ru/106Rh was more heterogeneous. Relative to 125I COMS plaque, both 106Ru/106Rh and protons have shown more confined dose distributions to the tumour volume in this situation, thus sparing other critical ocular structures. For protons, it has been shown that only doses lower than the maximum dose are delivered outside the tumour volume. Depending on the clinical situation, this may aid in the sparing of critical structures located in the sclera and optic disc boundary. The Monte Carlo model's statistical uncertainties of the mean dose estimates for the 106Ru/106Rh plaque and proton beam were 3 and 2.5%, respectively.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16604677     DOI: 10.1093/rpd/nci266

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  10 in total

1.  Assessment of targeting accuracy of a low-energy stereotactic radiosurgery treatment for age-related macular degeneration.

Authors:  Phillip J Taddei; Erik Chell; Steven Hansen; Michael Gertner; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

2.  Monte Carlo calculations and measurements of absorbed dose per monitor unit for the treatment of uveal melanoma with proton therapy.

Authors:  Nicholas Koch; Wayne D Newhauser; Uwe Titt; Dan Gombos; Kevin Coombes; George Starkschall
Journal:  Phys Med Biol       Date:  2008-02-25       Impact factor: 3.609

Review 3.  [CyberKnife®: new treatment option for uveal melanoma].

Authors:  J M Mor; R Semrau; W Baus; K R Koch; F Schaub; C Cursiefen; S Marnitz; L M Heindl
Journal:  Ophthalmologe       Date:  2018-04       Impact factor: 1.059

4.  Monte Carlo Estimation of Absorbed Dose Distributions Obtained from Heterogeneous 106Ru Eye Plaques.

Authors:  Francisco J Zaragoza; Marion Eichmann; Dirk Flühs; Wolfgang Sauerwein; Lorenzo Brualla
Journal:  Ocul Oncol Pathol       Date:  2017-02-23

5.  Accurate estimation of dose distributions inside an eye irradiated with 106Ru plaques.

Authors:  L Brualla; J Sempau; F J Zaragoza; A Wittig; W Sauerwein
Journal:  Strahlenther Onkol       Date:  2012-11-18       Impact factor: 3.621

6.  Monte Carlo Simulation of the Treatment of Eye Tumors with (106)Ru Plaques: A Study on Maximum Tumor Height and Eccentric Placement.

Authors:  Lorenzo Brualla; Francisco J Zaragoza; Wolfgang Sauerwein
Journal:  Ocul Oncol Pathol       Date:  2014-05-07

7.  Monte Carlo Computation of Dose-Volume Histograms in Structures at Risk of an Eye Irradiated with Heterogeneous Ruthenium-106 Plaques.

Authors:  Francisco J Zaragoza; Marion Eichmann; Dirk Flühs; Beate Timmermann; Lorenzo Brualla
Journal:  Ocul Oncol Pathol       Date:  2020-07-20

8.  Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

Authors:  U Titt; N Sahoo; X Ding; Y Zheng; W D Newhauser; X R Zhu; J C Polf; M T Gillin; R Mohan
Journal:  Phys Med Biol       Date:  2008-07-31       Impact factor: 3.609

9.  Preliminary results of proton radiotherapy for choroidal melanoma - the Kraków experience.

Authors:  Beata Sas-Korczyńska; Anna Markiewicz; Bożena Romanowska-Dixon; Elżbieta Pluta
Journal:  Contemp Oncol (Pozn)       Date:  2014-06-26

10.  Gold nanoparticle-based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye.

Authors:  Somayeh Asadi; Mehdi Vaez-zadeh; S Farhad Masoudi; Faezeh Rahmani; Courtney Knaup; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102